Drawing
THIS
COPY
IS
PROVIDED
ON
A
RESTRICTED
BASIS
AND
IS
NOT
TO
BE
USED
IN
ANY
WAY
DETRIMENTAL
TO
THE
INTERESTS
OF
PANDUIT
CORP.
0
4/1/22
DFA STMP MSAD INITIAL RELEASE GAECN06496
REV
DATE
BY
CHK
APR
DESCRIPTION
ECN
B
AA
B
1
2
2
1
18I216AX/01
18I216AX_DC/00
D10100DB/17
TITLE
VERISAFE
2.0
ABSENCE OF VOLTAGE TESTER
CUSTOMER
DRAWING
ITEM
REVISION
NAME
DATASET
FILE
NAME
MATERIAL:
UNLESS
OTHERWISE
SPECIFIED,
DIMENSIONAL
TOLERANCES
ARE:
IN
[mm]
N/A
.X
.03
[.75]
.XXX
.010
[.25]
.XX
.02
[.50]
ANGLES
5
DRAWING
NUMBER:
THIRD
ANGLE
PROJECTION
18I216AX_DC
DRAWN
BY
DATE
CHK
SCALE
SIZE
DFA
4/1/22
MSAD NONE SHT 1 OF 1
B
30MM
PANEL
KNOCK-OUT
BEHIND
PANEL
NOTES:
1. Mount for #4 or #6 Pan Head Screw, 3 Places, Min.
2. DIN Rail Mounting Feature
3. Lead Wires, QTY 6 or 8 - 14 AWG (2.08mm2)
4. Mating Connector Included. (VS2-NET connection if used)
READ PRODUCT INSTRUCTIONS BEFORE USING
PANDUIT PART NUMBER:
GENERAL SPECIFICATIONS:
Voltage detection Range: Up to 1000VAC (50/60Hz), 1000VDC
Overvoltage Category: CAT III (1000V); CAT IV (600V)
Degree of Protection:
Type (UL, NEMA, CSA) 1, 12,4, 4X, 13, IP66, IP67, IP69**
Environmental
Operating Temperature: -25
°
C to +60
°
C (-13
°
F to 140
°
F)
Storage Temperature: -45
°
C tp +85
°
C (-49
°
F to +185
°
F)
Humidity: 5 to 90% non-condensing; Rated 80% at 40
°
C,
decreasing linearly to 50% at 60
°
C
Pollution Degree: 3
Altitude: Up to 5000 meters
Power Requirements:
Battery: 3.6V Lithium Battery
DC Power: 12-24VDC, 43mA @ 24V
PoE***: PoE (10/100), 15mA
*Degree of Protection Specified is related to Indicator Module only.
**Battery - Free Indicator module only
***VS2-NET is required to use PoE
PART
NUMBER
FOR
USE
IN
INDICATOR
MODULE
SYSTEM
CABLE
LENGTH
CARTON
WEIGHT
VS2-AVT-3PB-02
3
PHASE
AC
SYSTEMS
BATTERY
POWERED
2
FT.
(.6m)
4
lbs
(1.82kg)
VS2-AVT-3PB-08
8
FT
(2.4m)
4.2
lbs
(1.91kg)
VS2-AVT-3PB-16
16
FT.
(4.8m)
4.5
lbs
(2.05
kg)
VS2-AVT-3PF-02
BATTERY
FREE
2
FT.
(.6m)
3.9
lbs
(1.78kg)
VS2-AVT-3PF-08
8
FT
(2.4m)
4.2
lbs
(1.91kg)
VS2-AVT-3PF-16
16
FT.
(4.8m)
4.4
lbs (2
kg)
VS2-AVT-1PB-02
1
PHASE
OR
DC
SYSTEMS
BATTERY
POWERED
2
FT.
(.6m)
4
lbs
(1.82kg)
VS2-AVT-1PB-08
8
FT
(2.4m)
4.2
lbs
(1.91kg)
VS2-AVT-1PB-16
16
FT.
(4.8m)
4.4
lbs (2
kg)
VS2-AVT-1PF-02
BATTERY
FREE
2
FT.
(.6m)
3.9
lbs
(1.78kg)
VS2-AVT-1PF-02
8
FT
(2.4m)
4.2
lbs
(1.91kg)
VS2-AVT-1PF-16
16
FT.
(4.8m)
4.4
lbs (2
kg)
VS2
SYSTEM
CABLE
BATTERY-FREE
INDICATOR
0.18
4.57
0.08
2.03
1.20
30.48
1.44
36.50
2.66
67.57
BATTERY
POWERED
INDICATOR
3
PHASE
INDICATOR
SINGLE PHASE
INDICATOR
5.33
135.38
0.21
5.25
2.17
55.02
INDICATOR
MODULE
(SYSTEM
CABLES)
ABSENCE
OF
VOLTAGE
OUTPUTS
DC
POWER
IN
(OPT.)
(SEE
NOTE
4)
2.81
71.37
4.32
109.80
3.64
92.37
4.32
109.64
0.81
20.50
0.74
18.83
5.18
131.70
1.43
36.25
2.38
60.32
1.90
48.28
BATTERY-
FREE
INDICATOR
(ONLY
SINGLE
PHASE
IS
SHOWN)
3.20
81.28
2.65
67.31
PANEL
INSTRUCTION
LABEL
ISOLATION
MODULE
UNIT
MOUNTING
LOCATIONS
MARKED
'A'
(SEE
NOTE
1)
VS2-NET
ATTACHMENT
POINTS
MARKED
'B'
A
A
A
A
B
B
B
B
1.76
44.63
LEAD
WIRES
EXIT
HERE
(SEE
NOTE
3)
SEE
NOTE
2
1.68
42.57