Cut Sheet

www.panduit.com/verisafe
specifications
Insulation piercing connector for copper wire with two mechanically isolated taps. Optimized for use with
VeriSafe
AVT sensor leads when prepared with Panduit ferrules, P/N F80-12-M.
VeriSafe
Insulation Piercing Connector
SPECIFICATION SHEET
applications
The VeriSafe
Insulation Piercing Connector provides a fast,
secure, and reliable way to terminate AVT sensor leads. The
compact connector design accommodates up to two taps in a
single housing that fully insulates both connections. The patent
pending connector allows taps to be made without compromising
the integrity of conductors and includes integrated strain relief.
Installation is fast and easy without the need to strip conductors.
Ideal for new and retrofit applications, connections can be made
without modifying existing conductor runs.
key features and benefits
Compact and
space saving:
Terminate two taps with a single connector
Fewer parts, less space needed for each installation
Optimized for use with VeriSafe
Absence of Voltage Tester sensor
leads
Fast installation: Insulation piercing design allows for installation without the need to strip
insulation from conductors
Easily retrofit existing cable runs without modifying conductors
Fully insulated design: Safe and reliable connections
Secure connections: Taps are made without compromising the integrity of conductors
Housing includes integrated strain relief
Flexible design: Family of connectors covers a wide range of cable runs
Suitable for new or retrofit applications
technical information
Cable run: 14 – 3/0 AWG (Copper conductors, solid or stranded Class B & C)
Taps: (2) 14 AWG stranded Class K
For VeriSafe AVT sensor leads prepared with F80-12-M ferrules
Connector materials: Housing – polyamide
Insulator – elastomeric polymer
Operating temperature: Up to 90°C (194°F)
Voltage range: 600V maximum
Standards &
compliance:
UL 486A-UL 486B, CSA C22.2 No 65-13
cULus listed
RoHS compliant
Insulation Piercing Connectors
VS-CKP14-6:
VeriSafe
Insulation
Piercing Connection Kit
for Tapping 14 to 6 AWG
conductors. Kit includes
3 connectors for
installment of 1 AVT.
VS-CKP4-000:
VeriSafe
Insulation
Piercing Connection Kit
for Tapping 4 to 3/0 AWG
conductors. Kit includes
3 connectors for
installment of 1 AVT.
Equipment Retrofit Kits
VS-AVT-RKP1: Complete kit to retrofit
equipment with VeriSafe
Absence of Voltage
Tester. Includes AVT
device with 10ft. sensor
leads, 8ft. system cable,
VeriSafe
Insulation
Piercing Connection
Kit 14-6 AWG power
connectors, (12) cable
ties, (6) cable ties mounts,
(1) wire marker card.
VS-AVT-RKP2: Complete kit to
retrofit equipment with
VeriSafe
Absence of
Voltage Tester. Includes
AVT device with 10ft.
sensor leads, 8ft. system
cable, VeriSafe
Insulation
Piercing Connection Kit
4 - 3/0 AWG power
connectors, (12) cable
ties, (6) cable ties mounts,
(1) wire marker card.

Summary of content (2 pages)