Cut Sheet

M.33
www.panduit.com
For service and technical support, call 866-405-6654 (outside the U.S. and Canada, see
catalog back cover).
A.
System
Overview
B.
Copper
Systems
C.
Fiber
Optic
Systems
D.
Power
over
Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
PHYSICAL INFRASTRUCTURE SYSTEMS
Ring Terminal, Vinyl Expanded Insulation
Expanded wire entry designed to accommodate wire with
a larger insulation thickness
Ring tongue design assures a secure connection in high
vibration applications
Insulation support helps to prevent wire damage in
bending applications
Brazed seam protects terminal barrel from splitting during
the crimp process
Internal barrel serrations assure good wire contact and
maximum tensile strength
UL Flammability UL 94V-0, maximum insulation
temperature 221°F (105°C)
UL and CSA rated up to 600 V per UL 486A/B
C
L
W
Part Number
Wire
Range
Color
Code
Max. Ins.
Dia.
Stud
Size Length Width Clearance
Panduit
Crimping
Tool
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
AWG mm
2
In. mm In. mm In. mm In. mm In. mm
PV14-8RX-C
16 – 14
AWG
1.5 – 2.5 Blue
0.200 5.1 #8 M4 0.96 24.4 0.31 7.9 0.25 6.4
CT-100A‡,
CT-600-A‡,
CT-1550‡,
CT-1551‡,
CT-2500‡
100 500
PV14-10RX-C
0.200 5.1 #10 M5 0.96 24.4 0.31 7.9 0.25 6.4 100 500
PV14-14RX-L
0.200 5.1 1/4" M6 1.16 29.5 0.46 11.7 0.37 9.4 50 500
PV14-56RX-L
0.200 5.1 5/16" M8 1.16 29.5 0.46 11.7 0.37 9.4 50 500
PV14-38RX-L
0.200 5.1 3/8" M10 1.25 31.8 0.53 13.5 0.42 10.7 50 500
PV10-8RX-L
12 – 10
AWG
4.0 – 6.0 Yellow
0.250 6.4 #8 M4 1.10 27.9 0.31 7.9 0.30 7.6
CT-100A‡,
CT-600-A‡,
CT-1550‡,
CT-1551‡,
CT-2500‡
50 500
PV10-10RX-L
0.250 6.4 #10 M5 1.10 27.9 0.31 7.9 0.30 7.6 50 500
PV10-14RX-L
0.250 6.4 1/4" M6 1.29 32.8 0.52 13.2 0.39 9.9 50 500
PV10-56RX-L
0.250 6.4 5/16" M8 1.29 32.8 0.52 13.2 0.42 10.7 50 500
PV10-38RX-L
0.250 6.4 3/8" M10 1.35 34.3 0.58 14.7 0.46 11.7 50 500
PV8-10RX-QY
8 AWG 10.0 Red
0.360 9.1 #10 M5 1.52 38.6 0.47 11.9 0.43 10.9
CT-720 with Die Insert
CD-720PV8-2‡,
CT-2600 with Die Insert
CD-2600-PV8‡
25 250
PV8-14RX-QY
0.360 9.1 1/4" M6 1.52 38.6 0.47 11.9 0.43 10.9 25 250
PV8-56RX-QY
0.360 9.1 5/16" M8 1.62 41.2 0.59 15.0 0.51 13.0 25 250
PV8-38RX-QY
0.360 9.1 3/8" M10 1.62 41.2 0.59 15.0 0.51 13.0 25 250
PV8-12RX-XY
0.360 9.1 1/2" M12 1.74 44.2 0.82 20.8 0.51 13.0 10 100
PV6-10RX-X
6 AWG 16.0 Blue
0.436 11.1 #10 M5 1.61 40.9 0.47 11.9 0.43 10.9
CT-720 with Die Insert
CD-720PV8-2‡,
CT-2600 with Die Insert
CD-2600-PV6‡
10 100
PV6-14RX-X
0.436 11.1 1/4" M6 1.61 40.9 0.47 11.9 0.43 10.9 10 100
PV6-56RX-X
0.436 11.1 5/16" M8 1.73 43.9 0.62 15.8 0.51 13.0 10 100
PV6-38RX-X
0.436 11.1 3/8" M10 1.73 43.9 0.62 15.8 0.53 13.5 10 100
PV4-14RX-E
4 AWG 25.0 Yellow
0.515 13.1 1/4" M6 1.87 47.5 0.55 14.0 0.53 13.5
CT-720 with Die Insert
CD-720PV8-2‡,
CT-2600 with Die Insert
CD-2600-PV4‡
20 200
PV4-56RX-E
0.515 13.1 5/16" M8 1.94 49.3 0.68 17.3 0.53 13.5 20 200
PV4-38RX-E
0.515 13.1 3/8" M10 1.94 49.3 0.68 17.3 0.53 13.5 20 200
PV4-12RX-E
0.515 13.1 1/2" M12 2.03 51.6 0.86 21.8 0.53 13.5 20 200
PV2-14RX-XY
2 AWG 35.0 Red
0.632 16.1 1/4" M6 1.94 49.3 0.68 17.3 0.58 14.7
CT-720 with Die Insert
CD-720PV8-2‡,
CT-2600 with Die Insert
CD-2600-PV2‡
10 100
PV2-56RX-XY
0.632 16.1 5/16" M8 1.94 49.3 0.68 17.3 0.58 14.7 10 100
PV2-38RX-XY
0.632 16.1 3/8" M10 1.94 49.3 0.68 17.3 0.58 14.7 10 100
PV2-12RX-XY
0.632 16.1 1/2" M12 2.03 51.6 0.86 21.8 0.58 14.7 10 100
‡UL and CSA approved tooling/product combinations.
For crimping tool information, see page M.46.
For the full selection of Panduit Crimping Tools see www.panduit.com.

Summary of content (1 pages)