Cut Sheet

TX6000
UTP Copper Cable
SPECIFICATION SHEET
applications
TX6000
UTP Copper Cable is a component of the Panduit
®
TX6000
UTP Copper Cabling System.
Interoperable and backward compatible, this end-to-end system provides design flexibility to protect
network investments well into the future. With certified performance to the ANSI/TIA-568-C.2 Category 6
and ISO 11801 Class E standards, this system will support the following applications:
Ethernet 10BASE-T, 100BASE-T (Fast Ethernet), 1000BASE-T (Gigabit Ethernet),
10GBASE-T (10 Gigabit Ethernet over limited distances as specified in the industry
10GBASE-T standards)
155 Mb/s ATM, 622 Mb/s ATM, 1.2 Gb/s ATM
Token Ring 4/16
TX6000
UTP Copper Cabling System
TX6000
UTP Copper Cable
Plenum: PUP6004*-W
Riser: PUR6004*-W
Mini-Com
®
TX6
PLUS UTP
Jack Module
Jack module: CJ688TG**
TX6
PLUS UTP Patch Cords
Foot lengths: UTPSP3***Y
Meter lengths: UTPSP1M^Y
DP6
PLUS Angled Punchdown
Patch Panels
24-port, 1 RU: DPA24688TGY
48-port, 2 RU: DPA48688TGY
DP6
PLUS Flat Punchdown
Patch Panels
12-port: DP12688TGY
24-port, 1 RU: DP24688TGY
48-port, 2 RU: DP48688TGY
GP6
PLUS Category 6
Punchdown System
See website (www.panduit.com) or catalog
for complete system information.
Cable Prep Tools
Wire snipping tool: CWST
Wire stripping tool: CJAST
*To designate a color, add suffix BU (Blue),
WH (White), YL (Yellow), IG (International Gray),
BL (Black), RD (Red), GR (Green), OR (Orange),
or VL (Violet).
**To designate color, add suffix IW (Off White),
EI (Electric Ivory), IG (International Gray),
WH (White), BL (Black), OR (Orange),
RD (Red), BU (Blue), GR (Green),
YL (Yellow), or VL (Violet).
***For lengths 1 to 20 feet (increments of one
foot) and 25, 30, 35, 40 feet, change the length
designation in part number to the desired
length. For standard cable colors other than
Off White, add suffix BL (Black), BU (Blue),
GR (Green), RD (Red), YL (Yellow),
OR (Orange), or VL (Violet) before Y at the
end of the part number. For example, the
part number for a blue, 15-foot patch cord
is UTPSP15BUY.
^For lengths 1 to 10 meters (increments of one
meter) and 0.5, 1.5, 2.5, 15, 20 meters, change
the length designation in the part number to
the desired length. For standard cable colors
other than Off White, add suffix BL (Black),
BU (Blue), RD (Red), YL (Yellow), GR (Green),
OR (Orange), or VL (Violet) before Y at the
end of the part number. For example, the
part number for a blue, 5-meter patch cord
is UTPSP5MBUY.
specifications
Category 6 cable shall exceed ANSI/TIA-568-C.2 and IEC
61156-5 Category 6 component standards. The conductors
shall be 23 AWG construction with FEP (CMP) or polyolefin
(CMR) insulation. The copper conductors shall be twisted
in pairs, separated by a cross-divider and covered by a low
smoke, flame-retardant (CMP) jacket or a
flame-retardant (CMR) jacket.
www.panduit.com
technical information
Electrical performance:
Certified channel performance in a 4-connector configuration up to 100 meters
and exceeds ANSI/TIA-568-C.2 Category 6 and ISO 11801
Class E standards at swept frequencies up to 250 MHz
Certified component performance up to 100 meters and exceeds the
component requirements of ANSI/TIA-568-C.2 and IEC 61156-5
Category 6 component standards at swept frequencies up to 250 MHz
Conductors/
insulators:
Plenum – 23 AWG bare copper wire covered by FEP insulation
Riser – 23 AWG bare copper wire covered by polyolefin insulation
Flame rating:
Plenum – NFPA 262 and CSA FT-6
Riser – UL1666 and CSA FT-4
PoE compliance:
Meets IEEE 802.3af and IEEE 802.3at for PoE applications
Installation tension:
25 lbf (110 N) maximum
Temperature rating:
32°F to 122°F (0°C to 50°C) during installation
-4°F to 167°F (-20°C to 75°C) during operation
Cable jacket:
Plenum – low smoke, flame-retardant PVC
Riser – flame-retardant PVC
Cable diameter:
0.225 in. (5.7mm) nominal
Cable weight:
Plenum – 30 lbs./1000 ft. (13.6 kg/305m)
Riser – 25 lbs./1000 ft. (11.4 kg/305m)
Packaging:
1000 ft. (305m), in easy payout carton
Package tested to ISTA Procedure 1A
key features and benefits
Third party tested
Cable has been tested as part of the TX6000
Copper Cabling System by
an independent laboratory and complies with the electrical channel
requirements of the following standard: ANSI/TIA-568-C.2 Category 6
Integrated pair divider
Separates pairs for exceptional cable performance
Easy payout carton
Ensures proper performance and provides quick installation
Tested beyond
the standards
Cable has been characterized to 550 MHz, 300 MHz above the standard
Descending length
cable markings
Easy identification of remaining cable reduces installation time and
cable scrap

Summary of content (2 pages)