Installation Manual

For Technical Support: www.panduit.com/resources/install_maintain.asp
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2015
FS006D
Page 8 of 11
Fiber Adapter Panels (FAPs):
Up to 4 for FEC1U & FCE1UA
Up to 8 for FCE2U
FOSM Fiber Optic Splice Module Installation (FOSMs not included)
Place L shape support brackets over
#10-32 studs on sliding tray, note orientation.
Place first FOSM on top of L shape support
brackets and secure with #10-32 hex nuts.
Remaining FOSMs are stacked on top of
each other and snap in place.
If 4 FOSMs are to be installed in the FCE1U
or FCE1UA, side latches on top module must
be broken off to close the enclosure drawer.
Position FAPs between upright flanges as
shown. Once mounted, fully seat NyLatch
fasteners to secure.
Break off FOSM latch
on top module only
Drawer shown fully extended
and tilted down
(cables omitted for clarity)
Fully extend drawer to ensure proper amount
of slack is used.
Finish splicing in each FOSM before
adding/stacking subsequent FOSMs.
FOSM:
Up to 4 for FEC1U & FCE1UA
Up to 8 for FCE2U
"L" shape
support
brackets
Figure 9
Figure 9A