Information
ELECTRICAL SOLUTIONS
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in BOLD.
D1.122
B2.
Cable
Accessories
C1.
Wiring
Duct
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
D2.
Power
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed 
& Write-On
Markers
F.
Index
B3.
Stainless
Steel Ties
C2.
Surface
Raceway
E5.
Lockout/
Tagout
& Safety
Solutions
B1.
Cable Ties
A.
System
Overview
D3.
Grounding
Connectors
E4.
Permanent
Identification
Part Number System for Reel Smart
™
Disconnects
D NF 14 250
FIB 3K
Type
NF = Nylon 
Funnel 
Entry
NG = Nylon 
Funnel Entry 
Metal 
Insulation Grip
NFR =  Nylon Funnel 
Entry Right Angle
PF = Premium Grade 
Nylon (Double Crimp)
V = Vinyl
B = Butted seam
C = Compression 
Tab
FB = Metal Insulation 
Grip, Female
FL = Fully Insulated
Positive Locking
Female
FIB = Fully Insulated, 
Butted Seam, 
Female
FIBX = Fully Insulated, 
Butted Seam, Female, 
Expanded Wire Entry
FIM = Fully Insulated Male
FIMB = Fully Insulated, Male, 
Oversized Housing
FIMX = Fully Insulated, Male, 
Expanded Wire Entry
M = Male
MB = Male Butted Seam
Wire Range
18 = #22 – 18
14 = #16 – 14
10 = #12 – 10
K = 1,000
KD = 1,500 
2K = 2,000 
3K = 3,000
110 = 0.110 x 0.032 tab size
111 = 0.110 x 0.020 tab size
145 = 0.145 x 0.032 tab size
187 = 0.187 x 0.032 tab size
188 = 0.187 x 0.020 tab size
205 = 0.187/0.205 x 0.032
tab size
206 = 0.187/0.205 x 0.020
tab size
250 = 0.250 x 0.032 tab size
0.187/0.205: Expandable 
receptacle will accept male tabs
from 0.187" to 0.205" widths in
0.032" or 0.020" thick styles.
Fully reliable connection 
through all widths.
—
Insulation
Size and Type
Special Configuration
Std. Pkg. Size
D = Disconnects
Supra-Grip
™
Female Disconnects, Nylon Fully Insulated – Funnel Entry
• Continuously molded design provides reliable, consistent
performance through the applicator for a high quality termination
every time 
• Disconnect can be inserted and removed from the male tab
without the use of tools for lower installed cost
• Flared barrel extension integrated into stamping to provide
insulation grip for double crimp requirements
• Internal barrel serrations assure good wire contact and maximum
tensile strength
• Internal wire stop assures proper length of insertion into terminal
barrel, providing a higher-quality connection
• Mates with DNF-FIMB family
• UL Flammability UL 94V-2/HB, maximum insulation temperature
221°F (105°C)
• UL and CSA rated up to 600 V per UL 310
*UL Recognized for copper alloy tabs only.
For applicator information, see page D1.143.
L
W
H
Type DNG-FB
Part Number
Wire
Range
Color
Code
Max.
Ins.
(In.)
Figure Dimensions 
(In.)
Tab
Size
CA9 
Series
Crimp Die
CA-800/EZ 
Series
Crimp Die
Pieces
Per 
Reel
L W H In. mm
DNG18-187FB-3K
22 – 18
AWG
Red 0.126
0.89 0.29 0.22 0.187 x 0.032 4.8 x 0.8
CD9-15A CD-800-15
3000
DNG18-188FB-3K
0.89 0.29 0.22 0.187 x 0.020 4.8 x 0.5 3000
DNG18-250FB-3K
0.93 0.35 0.23 0.250 x 0.032 6.3 x 0.8 3000
DNG14-187FB-3K*
16 – 14
AWG
Blue 0.153
0.89 0.29 0.25 0.187 x 0.032 4.8 x 0.8
CD9-16A CD-800-16
3000
DNG14-188FB-3K
0.89 0.29 0.25 0.187 x 0.020 4.8 x 0.5 3000
DNG14-250FB-3K
0.93 0.35 0.25 0.250 x 0.032 6.3 x 0.8 3000