User Guide
-6-
Priority of SPOT MONITOR CONTROL IN
The selection of the camera by SPOT MONITOR CONTROL
IN is set as first come, first served.
The Camera Selection Switch has a first priority against the
selection signal.
VTR Playback Mode
1. Set the Power Switch (1) to the ON position by press-
ing once. The switch remains down (
) keeping the
monitor and cameras ON.
2. Set the Mode Selection Switch (3) to the ON position.
3. Set the Input Selection Switch (4) to the EXT position
for observing the playback picture.
Automatic Reset function for Spot Monitor
Mode
This monitor has built-in automatic reset circuit. When the
AUTO RESET on the Set Up menu is set to the ON, the spot
monitoring mode is automatically reset to the sequential
switching mode at approx. 60sec. after the spot monitor
input signal received.
The automatic reset circuit is functioned according to the
spot monitor control input signals as ;
1. Alarm Sensors Signal
The selection of the camera by the alarm sensors sig-
nal is automatically reset at approx. 60 sec. and the
selection of the camera is returned to the sequential
switching.
2. Intercom Signal
(a) Intercom Communication
The selection of the camera by the intercom calling
signal is being held during intercom communication
and is reset to the sequential switching after intercom
communication is over.
(b) Intercom Calling
The selection of the camera by intercom calling signal
only is automatically reset at approx. 60 sec. and the
selection of the camera is returned to the sequential
switching.
3. Time Lapse VTR
When the Time Lapse VTR is connected with Colour
Mini CCTV System, the selection of the camera by
alarm sensors/intercom is automatically reset accord-
ing to the reset time of Time Lapse VTR and the selec-
tion of the camera is returned to the sequential switch-
ing.