User Guide

-18-
The maximum DC-resistance of the coaxial cable between the cameras and video
monitor is 20 ohms
Ambient Operating Temperature : 10°C - +50°C
Dimension : 370 (W) x 354 (H) x 389 (D) mm
Weight : Approx. 11 kg
Weights and dimensions shown are approximate.
Specifications are subject to change without notice.
Coaxial Maximum DC R/1000 ft. of
Cable Type Cable Length Inner Conductor
RG-59/U 660 ft. (200 m) Less than 30 ohms
RG-6/U 1650 ft. (500 m) Less than 12 ohms
SPECIFICATIONS
Power Source: WV-CM143/A, WV-CM143/B, WV-CM143/G: 220-240V AC 50 Hz
Power Consumption: Approx. 110W
CRT Size: 36.8 cm (14" diagonal)
Actual Visual Size: 33.5 cm (13" diagonal)
Camera Input: 1.0 Vp-p/75 ohms, composite × 4 (BNC)
Video Input: 1.0 Vp-p/75 ohms, composite × 1 (BNC)
Video Output: 1.0 Vp-p/75 ohms, composite × 1 (BNC)
Power Supply for Camera: Regulated current multiplex method (INPUT 1: selectable Camera Power On/Off)
Camera Switching : Manual/Auto (sequence) with auto bypass
Sequential Switching : Approx. 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 25, 30 sec. (selectable with Set Up menu)
Skip : Automatically
Auto Reset : Automatic reset circuit can function at 60 sec. after receiving the sensor signal.(Auto
reset on/off mode can be selected with set up menu)
Resolution : More than 330 lines at center
Sweep Linearity : Horizontal: 5% or less
Vertical: 5% or less
Sweep Distortion
Scanning Frequency: Horizontal: 15.625 kHz
Vertical: 50 Hz
Audio Input : 8 dB/Hi-z (pin-jack)
Audio Output : 10 dB/100 ohms (pin-jack)
Speaker Output : 1.0 W
Intercom / Sensor Input : 1 circuit par each camera
Alarm Output
Video Standby mode : 1 circuit
Standby mode : 1 circuit
Alarm time : Approx. 1, 5, 10, 20, 30, 40, 50, 60 sec. (selectable with Set Up menu)
Timing : Internal / External (electable with Set Up menu)
Extension Adaptor Input : 12-pin connector
Camera Extension Length :