User Guide

-17-
A1
A2
1
2
B1
B2
1
2
C1
C2
1
2
D1
D2
1
2
4 3 2 1
CAMERA INPUT
VIDEO OUT VIDEO IN
AUDIO OUT AUDIO IN
OUT
TIMING SELECT
IN
REMOTE OUT
ALARM
CONTROL
SPOT MONITOR CONTROL IN
4321
RESETGNDALL
MODE
STDBY
4321
GNDRECOVER
CAMERA
EXTENSION IN
FOCUS
4 3 2 1
CAMERA INPUT
VIDEO OUT VIDEO IN
AUDIO OUT AUDIO IN
OUT
TIMING SELECT
IN
REMOTE OUT
ALARM
CONTROL
SPOT MONITOR CONTROL IN
4321
RESETGNDALL
MODE
STDBY
4321
GNDRECOVER
CAMERA
EXTENSION IN
FOCUS
IN
GND
RESET
IN
RECOVER
OUT
GND OUT
ALARM
CAMERA POWER
OFF
CAMERA POWER
OFF
Main Unit
Colour Monitor
WV-CM143 (B)
Camera 1
Intercom
Coaxial Cable
Camera 2
Camera 3
Camera 4
Colour Monitor WV-CM143 (A)
BNC Connector
RCA pin plug
Recover Switch
Time Lapse VTR
CAMERA
SW OUT
220 - 240V
50 Hz
BNC Connector
Video
Distributor
220 - 240V
50 Hz
220 - 240V
50 Hz
Time Date
Generator
OUT
IN
OUT
IN
OUT
VIDEO IN
VIDEO OUT
Ground
Intercom 4
Intercom 3
Intercom 2
Intercom 1
Ground
Recover
Manual Select 4
Manual Select 3
Manual Select 2
Manual Select 1
Remote Control for Video Monitor
Setup Menu Setting is;
TIMING SELECT EXT
AUTO RESET OFF
Setup Menu Setting is;
TIMING SELECT EXT
AUTO RESET OFF
Notes:
1. When the alarm signal operation will be made in this
system Connect the Time Date Generator according to
the need.
2. When the alarm signal operation will be made in this
system, the alarm signal should be supplied from the
Time Lapse VTR.
Refer to the Operating Instructions of Time Lapse VTR
for details.
3. Input Selection Switch (4) of this monitor should be set
as shown below.
4. The Colour Monitor WV-CM143 (B) can not connect to
the camera.
5. The Colour Monitor WV-CM143 (A) does not allow the
Colour Monitor WV-CM143 (B) to recover into the
sequential mode.
6. Refer to the Operating Instruactions of Time Lapse VTR
for the recording detail.
VTR mode Setting Position
Monitor (A) Monitor (B)
Recording CAMERA EXT
Playback EXT EXT