Installation Guide
41
[Next] button
Proceeds to the settings for recording.
Step 8
Perform the settings for recording. If the settings are per-
formed on "Easy Start", the settings will be applied to all the
cameras.
[Frame rate]
Selects the frame rate for recording.
1 ips/ 3 ips/ 5 ips/ 10 ips/ 15 ips/ 30 ips
Default: 10 ips
[Image quality]
Selects the image quality of recorded images.
NQ (Normal): Standard quality
FQ (Fine): High quality
SF (Super Fine): Super fine quality
XF (Extra Fine): Extra fine quality
Default: FQ
Note:
• If"XF"isselectedwhenthecompressionmethodofthe
camera is not "H.264", "SF" will be set instead of "XF".
[Referenced recording days]
Calculates and displays the total number of days for which
recording on the hard disk drives is available.
Note:
• Thereferencedrecordingdayswillbecalculatedbased
on the assumption that recording is started on Monday.
• WhentheHDDsavingmodeisset,theactualrecording
days are longer than the referenced recording days.
(☞ Page 52)
• TheHDDconsumptionfortheeventrecordingwillbe
excluded.
• IfacameramanufacturedbyotherthanPanasonicis
used, the value of "Referenced recording days" will not
be displayed.
• Iftwoormorecameraswiththeimagecapturesizeof
"FHD(1920x1080)", the image quality of "XF" and the
frame rate of "10 ips" or more are connected, images
may not be recorded at the configured rate.
Step 9
Click the [Exit] button.
→ Saves the settings and returns to the top screen of the
setup menu.