User Guide

-12-
SYSTEM 1
The input video signals for this unit are not synchronized.
Notes :
When pressing the ALARM RESET/QUAD/SEQ/ECS button or the VIDEO SELECT/CURSOR/SELECT buttons, the pic-
ture on the video monitor may roll briefly at the time of switching.
The video signal to be recorded by the VTR should be supplied from the VTR OUT connector of this unit and not from
the VIDEO OUT/ESC connector of this unit, unless VTR servo control disturbances are allowable when setting the
ALARM RESET/ QUAD/SEQ/ECS button or the VIDEO SELECT/CURSOR/SELECT buttons.
Connections
Connect the VIDEO IN connectors of this unit to the video output connectors of the cameras.
Connect the VTR OUT connector of this unit to the video input connector of the time lapse VTR for recording.
Connect the VIDEO OUT connector of this unit to the video input connector of the video monitor.
VTR
OUT
1
VIDEO
OUT
ALARM/REMOTE
INOUT
2
VIDEO
INOUT
3
INOUT
4
INOUT
SIGNAL GND
Monitor
Monitor
VTR
WJ-MS424
VIDEO
VIDEO
VIDEO
VIDEO
SYSTEM CONNECTIONS