Operating Instructions Touch Panel Model No. TY-TP42P10S TY-TP50P10S TY-TP58P10S Before connecting, operating or adjusting this product, please read these instructions completely. Please keep this manual for future reference.
Accessories Before assembling, attaching and connecting anything, check all accessories have been included in the product package. Quantities are indicated in ( ).
Contents ■ Precautions with regard to setting up ............... 4 ■ Maintenance ......................................................... 6 ■ Names of Parts..................................................... 7 READ FIRST! READ FIRST! Installation & Setup ■ Mounting Touch Panel ........................................ 9 ■ Setup Procedure. ............................................... 13 ■ Driver Software Installation .............................. 14 ■ Connections and Plug-Ins .......................
Precautions with regard to setting up WARNING Do not allow the equipment to get wet. • If liquid splashes onto the equipment, wipe off with a dry cloth. In the unlikely event that liquid gets inside the product, unplug the USB cable and contact your dealer. Using the product with liquid still inside may cause a fire or electric shock. Do not disassemble or modify the equipment. • Doing so may cause a fire or electric shock. Do not touch the edge of the infrared transmissive part on the touch panel.
Precautions with regard to setting up Cautions when in use READ FIRST! Always keep the touch panel clean. • This optical touch panel utilizes infrared rays and may operate incorrectly if the infrared transmissive part becomes soiled. Use a soft dry cloth to clean the infrared transmissive part once every day. Use a power supply within the rated voltage range. • Be sure that the power supply used conforms to the rated voltage.
Maintenance Maintenance * Be sure to unplug the USB cable before cleaning the equipment. Clean the inside of the equipment once a year. • The equipment is of semi-sealed construction, so dust may eventually accumulate inside. This may cause poor operation due to a reduction in the level of infrared light available for touch detection. Cleaning frequency will vary depending on the setup location; if in doubt consult the dealer from whom you purchased the equipment.
Names of Parts Touch Panel (Front) READ FIRST! Top unit Left unit Right unit Bottom unit Touch Panel (Rear) USB port Touch Pen Attach the Velcro strip to the touch panel so as to hold the touch pen.
Touch Panel Assembly 1 Lay the top, side and bottom units on the packaging cushions. ㊍ Arrange the packaging cushions (6) on the floor so that their arrows point in the same direction. ㊎ Set the top, side and bottom units inside the grooves of the packaging cushions. (The arrows on the right and the left units should point toward the top unit.) Packaging cushions Top unit Caution Touch panel projections can be damaged if exposed, therefore lay panel parts in the packaging cushions to assemble.
Mounting Touch Panel (in Horizontal Posture) 1 Attach mounting brackets to the touch panel. ㊍ Fit the protrusion located above the round hole on mounting bracket A into the hole of the top unit and then tighten mounting screw A by hand. ㊎ As shown in the diagram, tighten mounting screw A by hand to hold mounting bracket B temporarily after fitting the protrusion located above the round hole on the mounting bracket B into the hole of the bottom unit.
Mounting Touch Panel (in Horizontal Posture) 3 Lock the touch panel to the plasma display. ㊍ Loosen mounting screw A on mounting bracket B (temporarily held) and rotate the bracket 90 degrees, as shown in the diagram, fit the protrusion located above the round hole on mounting bracket B into the hole of the bottom unit. Tighten both mounting screws A by hand.
Mounting Touch Panel (in Vertical Posture) 1 Attach mounting brackets to the touch panel. ㊍ Fit the protrusions on the vertical mounting brackets into the holes of the unit and affix the brackets with mounting screws B. ㊎ As shown in the diagrams, tighten mounting screws A by hand to temporarily hold the brackets A and B after fitting the protrusions located above the round holes on both brackets into the holes of the top and bottom units. Screw mounting screws A into the top and bottom units half way.
Mounting Touch Panel (in Vertical Posture) 3 Lock the touch panel to the plasma display. ㊍ Loosen mounting screws A on mounting brackets A and B (temporarily held) and rotate the brackets 90 degrees, as shown in the diagrams, fit the protrusions located above the round holes on the brackets into the holes of the top and bottom units. Then tighten both mounting screws A by hand.
Setup Procedure 1 Install the Driver Software P. 14 Do not connect the USB cable yet. Connect the touch panel and computer 3 Restart your computer P. 16 • After restarting your computer, check appears in the task tray. • If the icon does not appear, if it appears with an X over it or if an error message is displayed, see “Before Calling for Service” (p. 40) and “Error Messages”. (p. 42) 4 Calibrate the touch panel Installation & Setup 2 P. 27 This completes the basic setup.
Driver Software Installation Notes on Installation Connect the USB cable after installing the Driver software. For Windows 2000/XP : Log in with administrator privileges. For Windows Vista : For normal users to install the Driver software, users must input the administrator’s password. However, if the user account control (UAC) is inactivated, you must log in with administrator privileges. 1 Load the included CD-ROM into your computer. The setup program starts automatically.
Driver Software Installation 4 Click this button. Click this button. 5 Installation & Setup A warning message similar to that at left may appear. When the window at left appears, installation is complete. Click this button. The “LSaDrv” folder is saved in [All Programs] under the Start menu.
Connections and Plug-Ins 1 Activate power to the plasma display and computer. 2 Connect the touch panel and computer with the USB cable. Check that the computer’s OS starts up. When connected, Plug & Play starts. (p. 17) Caution • Connect the USB cable only after installing the Driver software. • Before connecting the USB cable, attach the ferrite core to the cable. (See below.) • Check that the USB power supply of your computer is a max. 500 mA.
Connections and Plug-Ins ■ Plug & Play Using Plug & Play, the touch panel is automatically detected as a USB device when the USB cable is connected. (The operating window that appears after that differs slightly according to OS.) Plug & Play starts up according to the number of connected touch panels. Windows 2000/Vista The “Found New Hardware” window appears and the device driver is automatically installed. However, with Windows Vista, installation ends without displaying any windows.
Connections and Plug-Ins ■ Checks After Installation Windows 2000/XP Select [Start] → [Control Panel] → [System] and then select [Device Manager] from the Hardware tab. Check that “Panasonic Touch Panel Unit” appears under “Universal Serial Bus controllers”. Windows Vista 1 Click on [Start] (Windows mark button) → [Control Panel] → [System and Maintenance] → [Device Manager]. A warning message similar to that at left may appear. Click this button.
Driver Software Uninstallation Note on Uninstallation Quit the Driver software before uninstalling it. (p. 20) Windows 2000/XP Select [Start] → [Control Panel] → [Add or Remove Programs]. 2 Select “LSaDrv”. Click this button. Windows Vista 1 Click on [Start] (Windows mark button) → [Control Panel] → [Programs] → [Programs and Features]. 2 Select “LSaDrv” from the “Uninstall or change a program” window. Installation & Setup 1 Click this button. Select “Yes” to uninstall the Driver software.
Touch Panel Setup How to Use the Driver Software ■ Driver Software Startup The Driver software starts up automatically when the computer starts up. Below is explained the procedure for manually starting up the Drive software. The Driver software can be started up in two ways. Method 1 Double-click on the “LSaDrv Driver” icon on the desktop. The Driver software starts up. Method 2 Select [Start] → [All programs] → [LSaDrv] → [LSaDrv Driver]. The Driver software starts up.
Touch Panel Setup Explanation of Setup Panel Items ■ The setup panel has three tabs: “Touch setting”, “Basic setting” and “Multi monitor”. * Touch screen: The combo box contains “Common setting” and names of registered touch panels. It is used to select touch panels for setting. The setup selected for “Common setting” is applied when the “Common setting is used” checkbox is selected when setting up registered touch panels. Apply: Applies the setup to the operation.
Touch Panel Setup (Explanation of Setup Panel Items) ■ Touch setting This tab is for optimizing touch panel use. (p. 29) Click action: This is the best setting if often using clicking operations (i.e., web link clicks, etc.). Drag action: This is the best setting if often using dragging operations (i.e., drawing, electronic blackboards, etc.). User setting: Applies the setup selected in the combo box. Default: Restores the setting made when the Driver software was first installed.
Touch Panel Setup (Explanation of Setup Panel Items) • Click mode Operation Drag (default) Click on touch Click on release1 Click on release2 Mouse mode Hovering Desktop mode When the pen touches the touch panel, the computer reacts like the mouse button was held down. When the pen is lifted off the touch panel, the computer reacts like the mouse button was released. Moving the pen across the touch panel is like dragging.
Touch Panel Setup (Explanation of Setup Panel Items) ■ Multi monitor This tab is used to input settings when using multiple monitors. (p. 35) When you tick “Using Multi-monitor.” on the “Basic setting” tab, the “Multi monitor” tab will appear. (p. 22) Setting of touch screen: Acquires the name of the touch panel to set up. List of registered and connected touch panels: Displays a list of touch panels connected to the computer as well as disconnected but registered touch panels.
Touch Panel Setup (Advanced setting) Advanced setting The “Advanced” window appears when the “Advanced” button on the “Basic setting” tab of the setup panel is clicked on. The “Touch screen”, “OK”, “Cancel” and “Apply” buttons operate in the same way as the common area buttons of the setup panel. (p. 21) ■ Common setting Show error message window: When a checkmark is placed in this checkbox, an error message is displayed if an error occurs.
Touch Panel Setup (Advanced setting) ■ Action setting Range for reducing offset: Unlike a mouse click, a touch can slip slightly. This slipping can be set so that it is recognized as a slip and not the user’s intention to drag an object. The higher the setting, the wider the slip area. (If set too low, clicking and double-clicking operations can be misinterpreted.
Touch Panel Setup Calibration If the touch position and cursor position do not match, the touch panel can be calibrated so that they do. Notes • If connecting multiple touch panels to a single computer in a multiple monitor environment, see “Multiple Monitor Setup”. (p. 35) • Use only the touch pen included with this touch panel. Operation is not guaranteed with other products. ㊍ Start up the setup panel. (p. 20) ㊎ Click on the “Basic setting” tab. Click this button.
Touch Panel Setup • precise calibration ㊍ precise calibration: This button activates the calibration window at the settings made in Setting of the number of precise calibration points and Margin specification of calibration points (see ㊐ below). ㊎ Setting of the number of precise calibration points: This area sets the number of points to display in the calibration window. The X (horizontal) axis and Y (vertical) axis appear on the calibration window.
Touch Panel Setup Touch setting ■ Click action This setting enables easy clicking operations on the touch panel. ㊍ Start up the setup panel (p. 20). ㊎ Click on the “Touch setting” tab. ㊏ Click on the “Click action” button. ㊐ Click on the “OK” or “Apply” button. Note The Click action button sets double-clicking range and time slightly longer than ordinary clicking and differentiates slight movements at the touch position from dragging so that clicking is accurately done by touching.
Touch Panel Setup ■ User setting Personalizing the touch panel setup by the way the panel is used makes it easier to use. Setups can be saved and changed according to how the panel is used. • Saving the Current Setup The current setup on the setup panel is added to the user setup. ㊍ Start up the setup panel (p. 20). ㊎ Click on the “Touch setting” tab. ㊏ Click this button. The user setting window opens. ㊐ Click this button. The “Add” window opens. ㊑ Input a setup name and details.
Touch Panel Setup • Calling Saved Setups ㊍ Select a setup from the user setting combo box (p. 22) and click on the “User setting” button. ㊎ Click on the “OK” or “Apply” button. • Changing Setups ㊍ Click on the “Edit” button on the “Touch setting” tab of the setup panel. The user setting window opens. ㊎ Select the user setup to change from the list and click on the “Edit” button. The “Add” window opens.
Touch Panel Setup Area Button Setup Various functions such as starting up specific applications or opening files can be assigned to virtual (area) buttons on the touch panel. ㊍ Start up the setup panel. (p. 20) ㊎ Click on the “Advanced” button on the “Basic setting” tab. ㊏éê Click on the “Direction setting” tab. Click this button. The Area button setting window opens. • In a multiple monitor environment, select the touch panel where wanting to create area buttons from the dropdown list.
Touch Panel Setup ■ Adding (Creating) Area Buttons Up to 30 area buttons can be created. ㊍ Click this button. Touch the location where wanting to create an area button and drag the pen. ㊎ • A square appears to indicate the area of the area button. When you remove the touch pen from the display, Area button function dialog box opens. ㊏ Assign an operation to the created area. Operation The diagonal lines in the background indicate the display area.
Touch Panel Setup Window operation: Windows sizes and the application quit command can be assigned to area buttons. ヂ Input the name of the window operation. ッ Select either “Minimize Window”, “Maximize Window”, “Restore the Size of Window” or “Exit Application”. Web browser: Area buttons can be created to open Internet Explorer or NetScape in a specific URL. ヂ Start up Internet Explorer or NetScape. ッ Input the name of the browser operation. ツ Select either “IE” or “NetScape”.
Touch Panel Setup Multiple Monitor Setup Multiple plasma displays can be connected to the same computer, fitted with touch panels and used accordingly. ■ Notes on Connecting Multiple Touch Panels Monitor No. The monitor Nos. set in Windows are used when registering the touch panels. • Checking Monitor Nos. ㊍ Open the Control Panel from the Start menu. ㊎ Click on “Display”. ㊏ Click on the “Settings” tab. ㊐ Click this button. Monitor Nos. appear in each of the monitor icons.
Touch Panel Setup ■ Registering Touch Panels ㊍ Start up the setup panel. (p. 20) ㊎ Place a checkmark in the “Using Multi-monitor” checkbox on the “Basic setting” tab. Click on the “Setting of touch screen” button on the “Multi monitor” tab. ㊏ When the window at left appears, touch the touch panel you want to register. ㊐ Check that the touch panel you touched is selected in the list and click on the “Regist” button. The Touch-screen registration window opens. ㊑ Edit the registration name.
Touch Panel Setup ■ Calibrating Touch Panels Once registered, touch panels can be calibrated to their respective plasma displays. ㊍ Start up the setup panel. (p. 20) ㊎ Select the touch panel to calibrate from the “Touch screen” pull-down menu. • Clicking on the “Select” button and touching a touch panel automatically selects that panel. ㊏ Click on the “Basic setting” tab. ㊐ Click this button. The calibration window opens. ㊑ Make settings. (p.
Touch Panel Setup ■ Setting Up Touch Panels ㊍ Start up the setup panel. (p. 20) ㊎ Select the touch panel to set up from the “Touch screen” pull-down menu. ㊏ Make settings. Note “Common setting is used” Checkbox: This command uses the setup selected as “Common setting” in the “Touch screen” drop-down list. When the “Common setting is used” checkbox is selected, it is unnecessary to make settings when individual settings are not needed. ㊐ Click on the “OK” or “Apply” button. Settings are applied.
Touch Panel Setup Setting Sensor Position Set the sensor position of the touch panel so that it corresponds to the position of the display. ㊍ Start up the setup panel. (p. 20) ㊎ Click on the “Basic setting” tab. ㊏ Click this button. ㊐ Click on the “Direction setting” tab. ㊑ Select the sensor position for the plasma display. Vertical Operation Horizontal Note If the touch panel is rotated before the sensor position is set, the touch direction and the direction in which the cursor moves will differ.
Before Calling for Service If you think the touch panel is broken or if it is not operating correctly, check the following before calling for service. Problem Check point Action to take Page The touch panel is an optical device that uses infrared rays. Incident light that contains large quantities of infrared rays can prevent proper functioning. Move light sources as far away from the touch panel as possible. Fluorescent light: Does not produce infrared light, so it does not cause problems.
Before Calling for Service Problem The touch position is out of place. The cursor poorly follows touching. Check point Calibrate the touch panel. 27 Has the touch panel been detached? If the touch panel is detached and then reattached, it may be installed in a slightly different position. This can cause the touch position not to align with the cursor position. Always calibrate the touch panel after it has been detached and reattached.
Error Messages If the Driver software detects an error, an error message is displayed. If an error message appears, remediate it as explained. Note Errors that do not affect touch detection, such as momentary communication errors, are restored automatically. Message Action to take Detailed action Can’t find a touch device. Check the cable connection and power switch position. Check the cable connection. USB error Controller error Sensor error Reset the controller and restart the computer.
Error Messages [Checking Your USB Host Controllers ] ㊍ Select [Control Panel] → [System] to open the Properties window and open the Device Manager window by clicking on [Device Manager] on the [Hardware] tab. (Example) ㊎ Click on the “+” left of “Universal Serial Bus controllers”. (A list of USB controllers opens.) • The USB controllers with the text “Host Controller” are host controllers. A USB bandwidth error warns that the host controller does not have enough bandwidth. • A USB 2.
Specifications Model Number TY-TP42P10S TY-TP50P10S Type TY-TP58P10S Touch Panel Power source Voltage +5V DC±10% Electric current Max. 450 mA Supply system From USB bus Detection system Infrared retroreflective detection Touch panel Panel window 938 mm (W) × 535 mm (H) 1,128 mm (W) × 648 mm (H) 1,305 mm (W) × 747.5 mm (H) Detection range 920 mm (W) × 518 mm (H) 1,106 mm (W) × 622 mm (H) 1,287 mm (W) × 723.
External Dimensions TY-TP42P10S 4 74.7 (Units: mm) 97.9 47.9 78.8 43 1,016.4 7 686 39 24.4 72 39 19.9 24.4 97.9 TY-TP50P10S 4 74.7 (Units: mm) 97.9 47.9 78.8 43 1,206.4 24.4 72 39 Troubleshooting 39 798.6 7 19.9 24.4 97.
External Dimensions TY-TP58P10S 75 4 (Units: mm) 1,395.4 93.8 47.9 47.4 100.4 45 923.1 7 24.4 82 45 19.9 24.4 100.
MEMO 47
Customer’s Record The model number and serial number of this product can be found on its bottom side. You should note this serial number in the space provided below and retain this book, plus your purchase receipt, as a permanent record of your purchase to aid in identification in the event of theft or loss, and for Warranty Service purposes. Warranty conditions are managed by distributors to meet the standards set by each country. For details, contact your dealer where you made your purchase.