Datasheet

TX-S
1
ds_61022_0022_en_txs: 061006J
SPECIFICATIONS
TYPICAL APPLICATIONS
SMALL POLARIZED
RELAY WITH HIGH
SENSITIVITY 50mW
TX-S RELAYS
TESTING
mm inch
8.2
.323
7.4
.291
15
.591
8.4
.331
7.4
.291
15
.591
SA type
FEATURES
High sensitivity
• 50mW nominal operating power
(single side stable 1.5-12V)
• Useful for electric-power-saving
Approx. 0.3µV low thermal
electromotive force
Outstanding surge resistance
Surge withstand between open contacts:
1,500V 10×160μs (FCC part 68)
Surge withstand between contacts and
coil:
2,500V 2×10μs (Telcordia)
Contact
Note:
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load. (AgPd contact type or SX relays are available for low level load
switching [10V DC, 10mA max. level])
Characteristics
Arrangement 2 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A )
100 mΩ
Contact material
Standard contact:
Ag+Au clad, AgPd contact
(low level load):
AgPd+Au clad (stationary),
AgPd (movable)
Rating
Nominal switching capacity
(resistive load)
1 A 30 V DC
Max. switching power
(resistive load)
30 W (DC)
Max. switching voltage 110 V DC
Max. switching current 1 A
Min. switching capacity
(Reference value)
#1
10 μA 10 mV DC
Nominal
operating
power
Single side stable
50 mW (1.5 to 12 V DC)
70 mW (24 V DC)
1 coil latching
35 mW (1.5 to 12 V DC)
50 mW (24 V DC)
2 coil latching
70 mW (1.5 to 12 V DC)
150 mW (24 V DC)
Expected
life (min.
operations)
Mechanical (at 180 cpm) 5×10
7
Electrical
(at 20 cpm)
1 A 30 V DC
resistive
2×10
5
Initial insulation resistance*
1
Min. 1,000 MW (at 500 V DC)
Initial
breakdown
voltage*
2
Between open contacts 750 Vrms for 1min.
Between contact sets 1,000 Vrms for 1min.
Between contacts and coil 1,800 Vrms for 1min.
Initial surge
voltage
Between open contacts
(10 × 160μs)
1,500V (FCC Part 68)
Between contacts and coil
(2 × 10 μs)
2,500V (Telcordia)
Operate time [Set time]*
3
(at 20°C)(at nominal voltage)
Max. 5 ms [Max. 5 ms]
Release time (without diode)
[Reset time]*
3
(at 20°C)(at nominal voltage)
Max. 5 ms [Max. 5 ms]
Temperature rise*
4
(at 20°C) Max. 50°C
Shock resistance
Functional*
5
Min. 750 m/s
2
{75 G}
Destructive*
6
Min. 1,000 m/s
2
{100 G}
Vibration resistance
Functional*
7
10 to 55 Hz at double
amplitude of 3.3 mm
Destructive
10 to 55 Hz at double
amplitude of 5 mm
Conditions for operation,
transport and storage*
8
(Not freezing and condensing
at low temperature)
Ambient
temperature
–40°C to +70°C
–40°F to +158°F
Humidity 5 to 85% R.H.
Unit weight Approx. 2 g .071 oz
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as “Initial breakdown voltage” section.
*
2
Detection current: 10mA
*
3
Excluding contact bounce time.
*
4
By resistive method; nominal voltage applied to the coil; contact carrying current:
1 A.
*
5
Half-wave pulse of sine wave: 6 ms; detection time: 10 μs
*
6
Half-wave pulse of sine wave: 6 ms
*
7
Detection time: 10 μs
*
8
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (p. 19, Relay Technical Information).
• Communications
(XDSL, Transmission)
• Measurement
•Security
• Home appliances, and audio/visual
equipment
• Automotive equipment
• Medical equipment