Datasheet

TX-D
–4–
ASCTB19E 201407-T
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. AgPd contact type is available for low level load switching (10V DC, 10mA max. level).
*2 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “AMBIENT ENVIRONMENT”
in GENERAL APPLICATION GUIDELINES.
REFERENCE DATA
Characteristics Item Specifications
Contact
Arrangement 2 Form C 2 Form D (M.B.B.type)
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material
Standard contact: Ag+Au clad,
AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable)
Rating
Nominal switching capacity
Standard contact: 2 A 30 V DC,
AgPd contact: 1 A 30 V DC (resistive load)
1 A 30 V DC (resistive load)
Max. switching power
Standard contact: 60 W (DC),
AgPd contact: 30 W (DC) (resistive load)
30 W (DC) (resistive load)
Max. switching voltage 220 V DC 110 V DC
Max. switching current Standard contact: 2 A, AgPd contact: 1 A 1 A
Min. switching capacity (Reference value)*
1
10μA10mV DC
Nominal operating
power
Single side stable 200mW (3 to 12 V DC), 230mW (24 V DC) 250mW (1.5 to 12 V DC), 270mW (24 V DC)
1 coil latching 150mW (3 to 12 V DC), 170mW (24 V DC)
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Initial breakdown voltage” section.
Breakdown
voltage (Initial)
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA) 500 Vrms for 1min. (Detection current: 10mA)
Between contact and coil 3,000 Vrms for 1min. (Detection current: 10mA) 3,000 Vrms for 1min. (Detection current: 10mA)
Between contact sets 1,000 Vrms for 1min. (Detection current: 10mA)
Surge breakdown
voltage (Initial)
Between open contacts 1,500 V (10×160μs) (FCC Part 68)
Between contacts and
coil*
1
6,000 V, 1.2 × 50μs
Temperature rise (at 20°C 68°F)
Max. 50°C 122°F
(By resistive method, nominal coil voltage applied to the coil;
contact carrying current: 2A [1A: M.B.B.].)
Operate time [Set time] (at 20°C 68°F) Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20°C 68°F)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Mechanical
characteristics
Shock
resistance
Functional
Min. 750 m/s
2
(Half-wave pulse of sine wave: 6 ms;
detection time: 10μs.)
Min. 500 m/s
2
(Half-wave pulse of sine wave: 11 ms;
detection time: 10μs.)
Destructive Min. 1,000 m/s
2
{100G} (Half-wave pulse of sine wave: 6 ms.)
Vibration
resistance
Functional 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 5 mm
Expected life
Mechanical Min. 10
8
(at 180 cpm) Min. 10
7
(at 180 cpm)
Electrical (Standard contact)
Min. 10
5
(2 A 30 V DC resistive),
Min. 5×10
5
(1 A 30 V DC resistive) (at 20 cpm)
Min. 10
5
(1 A 30 V DC resistive) (at 20 cpm)
Conditions
Conditions for operation, transport and
storage*
2
Ambient temperature: –40°C to +85°C –40°F to +185°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 20 cpm
Unit weight Approx. 2 g .071 oz
1. Maximum switching capacity 2. Life curve 3. Mechanical life
Tested sample: TXD2-5V, 10 pcs.
Operating speed: 180 cpm
0.2
0.3
0.4
0.5
1.0
2.0
3.0
20 30 50 100 200 3000
Contact voltage, V
DC resistive load
Switching current, A
1.0 2.0
100
50
30
20
10
0
30V DC
resistive load
Switching current, A
No. of operations ×10
4
Max.
Min.
Min.
Max.
0
10
20
30
40
50
60
70
80
90
100
No. of operations, ×10
4
Ratio against the rated voltage, %V
Pick-up voltage
Drop-out voltage
100001000100100