Operating Instructions High Definition Plasma Display Model No. TH-85PF12E Contents Important Safety Notice ........................................... 2 Safety Precautions ................................................... 3 Accessories .............................................................. 6 Connections .............................................................. 7 Power On / Off......................................................... 11 Selecting the input signal ..........................
Important Safety Notice WARNING 1) To prevent damage which may result in fire or shock hazard, do not expose this appliance to dripping or splashing. Do not place containers with water (flower vase, cups, cosmetics, etc.) above the set. (including on shelves above, etc.) No naked flame sources, such as lighted candles, should be placed on / above the set. 2) To prevent electric shock, do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel.
Safety Precautions WARNING Setup This Plasma Display is for use only with the following optional accessories. Use with any other type of optional accessories may cause instability which could result in the possibility of injury. (All of the following accessories are manufactured by Panasonic Corporation.) • Pedestal ......................................................................... TY-ST85P12 • Floor stand .....................................................................
Safety Precautions When using the Plasma Display The Plasma Display is designed to operate on 220 - 240 V AC, 50/60 Hz. Do not cover the ventilation holes. • Doing so may cause the Plasma Display to overheat, which can cause fire or damage to the Plasma Display. Do not stick any foreign objects into the Plasma Display. • Do not insert any metal or flammable objects into the ventilations holes or drop them onto the Plasma Display, as doing so can cause fire or electric shock.
Safety Precautions CAUTION When using the Plasma Display Do not bring your hands, face or objects close to the ventilation holes of the Plasma Display. • Heated air comes out from the ventilation holes at the top of Plasma Display will be hot. Do not bring your hands or face, or objects which cannot withstand heat, close to this port, otherwise burns or deformation could result. Be sure to disconnect all cables before moving the Plasma Display.
Accessories Accessories Supply Check that you have the accessories and items shown Operating Instruction book CD-ROM (Operating instructions) Ferrite core × 2 Remote Control Transmitter EUR7636090R Batteries for the Remote Control Transmitter (R6(UM3) Size × 2) Clamper × 1 Noise cut filter Use the Ferrite cores and Noise cut filter to Use the clamper comply with the EMC standard. (see page when connecting a LAN cable.
Connections AUDIO OUT Terminals connection R L AUDIO OUT Stereophonic sound code audio equipment line-in AC cord connection (see page 11) – AC cord fixing Close Push until the hook clicks. Open Unplug the AC cord pressing the two knobs. 2. Pull off. 1 Plug the AC cord into the display unit. Plug the AC cord until it clicks. 2 Fix the AC cord with the clamper. Note: Make sure that the AC cord is locked on both the left and right sides. Unplug the AC cord 1. Keep the knob pressed.
Connections PC Input Terminals connection (Female) COMPUTER AUDIO PC IN Conversion adapter (if necessary) RGB Mini D-sub 15p PC cable Audio (Male) Stereo plug Connect a cable which matches the audio output terminal on the computer. Notes: • With regard to the typical PC input signals that are described in the applicable input signals list, adjustment values such as for the standard picture positions and sizes have already been stored in this unit.
Connections SERIAL Terminals connection The SERIAL terminal is used when the Plasma Display is controlled by a computer. Note: To use serial control for this unit, make sure to set the “Control I/F Select” in the “Network Setup” menu to “RS-232C”. (Male) COMPUTER 1 2 6 3 7 4 8 5 9 SERIAL RS-232C Straight cable Pin layout for SERIAL Terminal (Female) D-sub 9p Notes: • Use the RS-232C straight cable to connect the computer to the Plasma Display. • The computer shown is for example purposes only.
Connections DVI-D connection This unit has terminal boards equivalent to DVI-D Terminal Board (TY-FB11DD) as standard equipment. PC with DVI-D video out DVI-D video cable (Within 5 m) AUDIO DVI-D IN SLOT2 Mini-plug (M3) DVI-D Input Connector Pin Layouts 24 Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 17 16 9 8 1 Connection port view Signal Name T.M.D.S. data 2T.M.D.S. data 2+ T.M.D.S. data 2 shield Pin No. 13 14 15 16 17 18 19 20 21 22 23 24 DDC clock DDC data T.M.D.S. data 1T.M.D.S. data 1+ T.M.D.S.
Power On / Off Connecting the AC cord plug to the Plasma Display. Fix the AC cord plug securely to the Plasma Display with the clamper. (see page 7) Connecting the plug to the Wall Outlet Notes: • Main plug types vary between countries. The power plug shown at right may, therefore, not be the type fitted to your set. • When disconnecting the AC cord, be absolutely sure to disconnect the AC cord plug at the socket outlet first. Press the Power switch on the Plasma Display to turn the set on: Power-On.
Power On / Off When first switching on the unit Following screen will be displayed when the unit is turned on for the first time. Select the items with the remote control. Unit buttons are invalid. OSD Language English (UK) OSD Language Deutsch 1 Français Select the language. Italiano Español 2 ENGLISH (US) Set. Select Set PRESENT TIME Setup 1 Select “DAY” or “PRESENT TIME”. 2 Setup “DAY” or “PRESENT TIME”. 1 Select “Set”.
Selecting the input signal Select the input signals to be connected by installing the optional Terminal Boards. Press to select the input signal to be played back from the equipment which has been connected to the Plasma Display. Input signals will change as follows: INPUT1 INPUT2 INPUT3 PC Press the INPUT “1”, “2”, “3” or “PC” input mode selection button to select the input mode. This button is used to switch directly to INPUT mode. These buttons can only display the slot which is installed.
Basic Controls Main Unit Right side surface ENTER/ + / VOL - Remote control sensor Power Indicator The Power Indicator will light. • Power-OFF .... Indicator not illuminated (The unit will still consume some power as long as the power cord is still inserted into the wall outlet.) • Standby ........ Red Orange (When “Slot power” is set to “On”.) Orange (Depending on the type of the function board installed, when the power is supplied to the slot) Orange (When “Control I/F Select” is set to “LAN”.
Basic Controls Remote Control Transmitter Status button Press the “Status” button to display the current system status. 1 Input label 2 Aspect mode NANODRIFT Saver operating 3 Off timer The off timer indicator is displayed only when the off timer has been set. 4 Clock display R button (see page 16) Press the R button to return to previous menu screen. Standby (ON / OFF) button The Plasma Display must first be plugged into the wall outlet and turned on at the power switch (see page 11).
On-Screen Menu Displays Remote Control 1 Display the menu screen. MENU Press to select. (Example: Picture menu) 2 Select the item. Select. Picture Normalise Normal Picture Mode Contrast Brightness Colour Hue Sharpness White balance Colour Management Advanced settings Unit Each time the MENU button is pressed, the menu screen will switch. Normal Viewing Picture Sound Pos. /Size Setup ENTER/ + Normal - Press. / VOL 25 0 0 0 5 Press several times. Select.
On-Screen Menu Displays Overview Note: Menu that cannot be adjusted is grayout. Adjustable menu changes depending on signal, input and menu setting. Pos.
Using Network Function This unit has a network function to control the network connected display with your computer. Note: To use the network function, set each “Network Setup” setting and make sure to set the “Control I/F Select” to “LAN”. When “LAN” is set, the slot power is turned on, and power indicator is lit orange under the condition of power “Off” with remote control (stand-by state), regardless of the “Slot power” setting.
Specifications TH-85PF12E 220 - 240 V AC, 50/60 Hz Power Source Power Consumption Power on Stand-by condition Power off condition Plasma Display panel 1,100 W Save off 1.2 W, Save on 0.7 W 0.4 W Drive method : AC type 85-inch, 16:9 aspect ratio 1,889 mm (W) × 1,062 mm (H) × 2,167 mm (diagonal) 2,073,600 (1,920 (W) ×1,080 (H)) [5,760 × 1,080 dots] Screen size (No.
Information for Users on Collection and Disposal of Old Equipment and used Batteries These symbols on the products, packaging, and/or accompanying documents mean that used electrical and electronic products and batteries should not be mixed with general household waste. For proper treatment, recovery and recycling of old products and used batteries, please take them to applicable collection points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC.