Datasheet

SFN4D
2
ds_61408_0000_en_sfn4d: 141106D
COIL DATA (at 20°C)
SWITCHING CAPABILITY
Making / breaking capacities according to EN 60947-5-1: 2000, table 4 / 5; AC15: 6A 230V AC / DC13: 6A 24V DC
Endurance / overload test according to UL 508 16 edition, sections 42 / 43; 6A 250V AC / 6A 24V DC; B300 / R300; File E120782
ELECTRICAL LIFE (Reference Data)
*1
DIMENSIONS
Part number Coil nominal voltage V DC
Operate voltage
*1
V DC
*1 Operate and release voltage at different temperatures, see “REFERENCE DATA” on page 3, coil voltage characteristics.
Release voltage
*1
V DC
Coil resistance
Ω (
±10%, 20°C)
SFN4D-DC5V 5
3.75
1.25
64.1
SFN4D-DC9V 9
6.75
2.25
207.7
SFN4D-DC12V 12
9.00
3.00
369.2
SFN4D-DC16V 16
12.00
4.00
656.4
SFN4D-DC18V 18
13.5
4.50
830.8
SFN4D-DC21V 21
15.75
5.25
1130.8
SFN4D-DC24V 24
18.00
6.00
1476.9
SFN4D-DC36V 36
27.00
9.00
3085.7
SFN4D-DC48V 48
36.00
12.00
5485.7
SFN4D-DC60V 60
45.00
15.00
8571.4
Voltage Current (A) Load type Frequency Duty cycle No. of contacts No. of ops.
230V AC 8 AC 1 0.25Hz 25% 4
85,000
230V AC 6 AC 1 0.25Hz 25% 4
200,000
230V AC 2.5 AC 1 0.25Hz 25% 4
1,500,000
230V AC 60 / 6 AC 15 0.20Hz 20% 3
40,000
24V DC 6 DC 1 0.25Hz 25% 4
2,000,000
250V DC 0.27 DC 13 0.10Hz 10% 4
>1,000,000
*2
*1 Test conditions: Room temperature, breathing hole closed, dielectric strength according to EN61810-1:2004.
*2 Has to be confirmed
PC board pattern (Bottom view)Schematic (Bottom view)
Outer dimensions
9
7
5
+1
16
14
12
2-
10
8
15
13
611
53.3
0.3 Stand-off
33
3.34
12.5
12.5
7.57.5
15155.4
15 15
53.3
12.5
1
5.4 5.4
General tolerance: 0.3
±
Projection mode:
33
14.53
0.3 (2x)
3.34
12.5 7.5 7.5
0.48 (12x)
(2.16)
Breathing hole
1.4 dia., typical value for manual insertion