Datasheet

S
6
ds_61A07_en_s: 270513D
TYPES
SPECIFICATIONS
NOTES
ACCESSORIES
S RELAYS
SOCKET
Product name Part No.
S Relays Socket S-PS
Maximum continuous current
4 A
Note: Don’t insert or remove relays while in the energized condition.
Breakdown voltage 1,500 Vrms between terminals
Insulation resistance More than 100 M between terminals at 500 V DC Mega
Heat resistance 150 3C (302 5.4F) for 1 hour.
S-PS
DIMENSIONS (Unit: mm inch)
External dimensions
General tolerance: 0.3 .012
12.4±0.6
18.3±0.6
15.5±0.6
3.4±0.3
0.4±0.1
1.2±0.3
4.85±0.3
5.08±0.3
32.4±0.6
1.5±0.3 1.5±0.3
7.62±0.3
Terminal width: 1.3
Terminal thickness: 1.2
.051
.047
1.276±.024
.059±.012 .059±.012
.610±.024
.134±.012
.016±.004
.300±.012
.200±.012
.488±.024
.720±.024
.047±.012
.191±.012
PC board pattern
(Copper-side view)
Tolerance: 0.1 .004
7.6
5.085.085.085.085.08
12-1.6 dia. hole
.299
12-.063 dia. hole
.200.200.200.200.200
Inserting and removing method
Inserting method: Insert the relay as
shown in Fig. 1 unit the rib of the relay
snaps into the clip of the socket.
Rib
Fig. 1
Removing method:
(1) Remove the relay straight from the
socket holding the shaded portion of the
relay as shown in Fig. 2.
Fig. 2
(2) When sockets are mounted in close
proximity, use a slotted screw driver as
shown in Fig. 3.
Fig. 3