Datasheet
S
–3–
ASCTB207E 201701-T
2) 2 coil latching
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
3. Electrical life
Condition: Resistive load, at 20 times/min.
Type
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
Nominal operating
current [±10%]
(at 20°C 68°F)
Coil resistance [±10%]
(at 20°C 68°F)
Nominal operating
power
(at 20°C 68°F)
Max. applied
voltage
(at 40°C 104°F)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
Standard
3V DC
70%V or less of
nominal voltage
(Initial)
70%V or less of
nominal voltage
(Initial)
66.7mA 66.7mA 45Ω 45Ω 200mW 200mW 5.5V DC
5V DC 38.5mA 38.5mA 130Ω 130Ω 192mW 192mW 9.0V DC
6V DC 33.7mA 33.7mA 180Ω 180Ω 200mW 200mW 11.0V DC
12V DC 16.7mA 16.7mA 720Ω 720Ω 200mW 200mW 22.0V DC
24V DC 8.4mA 8.4mA 2,850Ω 2,850Ω 202mW 202mW 44.0V DC
48V DC 7.4mA 7.4mA 6,500Ω 6,500Ω 355mW 355mW 65.0V DC
Characteristics Item Specifications
Contact
Arrangement 2 Form A 2 Form B, 3 Form A 1 Form B, 4 Form A
Contact resistance (Initial) Max. 50 m
Ω (By voltage drop 6 V DC 1A)
Electrostatic capacitance (initial) Approx. 3pF
Contact material Au clad Ag alloy (Cd free)
Thermal electromotive force (at nominal coil voltage)
(initial)
Approx. 3μV
Rating
Nominal switching capacity (resistive load) 4 A 250 V AC, 3 A 30 V DC
Max. switching power (resistive load) 1,000 VA, 90 W
Max. switching voltage 250 V AC, 48 V DC (30 to 48 V DC at less than 0.5 A)
Max. switching current 4 A (AC), 3 A (DC)
Min. switching capacity (Reference value)*
1
100μA 100 m V DC
Electrical
characteristics
Insulation resistance (Initial)
Min. 10,000MΩ (at 500V DC)
Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 750 Vrms for 1min. (Detection current: 10mA.)
Between contact sets 1,000 Vrms for 1min. (Detection current: 10mA.)
Between contact and coil 1,500 Vrms for 1min. (Detection current: 10mA.)
Operate time [Set time] (at 20°C 68°F) Max. 15 ms [15 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20°C 68°F)
Max. 10 ms [15 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Mechanical
characteristics
Shock resistance
Functional Min. 490 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Destructive Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 3 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 4 mm
Expected life Mechanical Min. 10
8
(at 50 cps)
Conditions Conditions for operation, transport and storage*
2
Ambient temperature: –55°C to +65°C –67°F to +149°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Unit weight Approx. 8 g .28 oz
Types Switching capacity No. of operations
2 Form A 2Form B, 3 Form A 1 Form B, 4 Form A
4A 250 V DC Min. 1×10
5
3A 30V DC Min. 2×10
5