Datasheet
RT-3 (Power PhotoMOS Relay type)
744
PERFORMANCE
Notes: 1. The value of breakdown voltage and insulation resistance is the initial one.
2. Condensing occurs when the unit relay is exposed to sudden temperature change in a high temperature and high humidity atmosphere. This
may cause some troubles like insulation failure of the socket or the print circuit board. Take care under this condition.
3. Below 0°C 32°F, condensing water can freeze and cause socket contact failures and other problems. Take care under this condition.
DATA
RT3SP1-12V, RT3SP1-24V, RT3SP2-12V AND RT3SP2-24V CAN BE EQUIPPED
WITH THE RELAYS BELOW
(per relay, at 25°C 77°F, initial)
Notes: 1. Peak load current is limited to “100 ms, 1 shot”.
2. The ratings per point in the table above also apply during 4-point simultaneous operation.
3. Please use a load current that is within the range of the data given below in “Load current vs. ambient temperature characteristics”.
4. Be very careful regarding the polarity on the output side when equipped with AQZ10∗ (dedicated power PhotoMOS DC type).
5. Never equip a product with a relay other than those given above. Doing so can cause product malfunction, breakdown, and breakdown of
connected devices.
Item Performance
Breakdown voltage
Between input and output 2,000 Vrms for 1 min.
Between different terminals
(between relays, both ways)
1,500 Vrms for 1 min.
Insulation resistance Min. 100 MΩ (Using 500 V DC megger, measuring same place as breakdown voltage.)
Vibration resistance (destructive) 10 to 55 Hz at double amplitude 1 mm .039 inch
Shock resistance (destructive) Min. 196 m/s
2
{20G}
Ambient temperature –20°C to +55°C –4°F to +131°F
Ambient humidity 35% to 85% R.H. (Not condensing)
Storage temperature –30°C to +80°C –22°F to +176°F (Not freezing and condensing)
Terminal screw fasten torque 0.3 to 0.5 N·m {3 to 5 kgf·cm}
Cross connection protecting diode 1.5 A, inverse voltage 40 V
Weight Approx. 100 g 3.53 oz
RT-3 unit relay
Possible relays Output
Type Part No.
Maximum load
voltage
Recommended load voltage
Continuous
load current
Peak load
current
RT3SP1-12V
RT3SP1-24V
Power PhotoMOS Relay
(DC only)
AQZ102 60V DC 0 to 30V DC 2.00A 9.0A
AQZ105 100V DC 0 to 50V DC 1.50A 6.0A
AQZ107 200V DC 0 to 100V DC 0.70A 3.0A
AQZ104 400V DC 0 to 200V DC 0.40A 1.5A
RT3SP2-12V
RT3SP2-24V
Power PhotoMOS Relay
(AC/DC dual use)
AQZ202 60V (peak) 0 to 12V AC/0 to 30V DC 1.80A 9.0A
AQZ205 100V (peak) 0 to 24V AC/0 to 50V DC 1.20A 6.0A
AQZ207 200V (peak) 0 to 48V AC/0 to 100V DC 0.60A 3.0A
AQZ204 400V (peak) 0 to 125V AC/0 to 200V DC 0.30A 1.5A
AQZ404
(1 Form B type)
400V (peak) 0 to 125V AC/0 to 200V DC 0.30A 1.5A
Lord current vs. ambient temperature
characteristics
Allowable ambient temperature: –20°C to +55°C
–4°F to +131°F
1
2
–20
–4
–10
14
0
32
10
50
20
68
30
86
40
104
50
122
60
140
Ambient temperature, °C °F
Load current, A
RT3SP2-12 or 24 V
(AQZ204 equipped type)
RT3SP1-12 or 24 V
(AQZ102 equipped type)