Datasheet
4-POINT TERMINAL
2) Input rating when Power PhotoMOS relay voltage sensitive type installed in 4-POINT TERMINAL (per relay, at 25°C 77°F)
2. Output rating (per relay)
Note: The value above is the allowable value when no relay is installed.
Please note that limitations apply to the load voltage and current depending on the type of relay installed.
1) Output rating when PA relay installed in 4-POINT TERMINAL (per relay, at 20°C 68°F)
Note: During 4-point operation, the rating of each relay is also as shown above.
2) Output rating when Power PhotoMOS relay voltage sensitive type installed in 4-POINT TERMINAL (per relay, at 25°C 77°F)
Notes: 1. During 4-point operation, the rating of each relay is also as shown above.
2. The load current varies depending on ambient temperature. Refer to the Load current vs. ambient temperature characteristic data.
SPECIFICATIONS
Notes: 1. The value of breakdown voltage and insulation resistance is the initial one.
2. Condensing occurs when the unit relay is exposed to sudden temperature change in a high temperature and high humidity atmosphere.
This may cause some troubles like insulation failure of the socket or the print circuit board. Take care under this condition.
3. Below 0°C 32°F, condensing water can freeze and cause socket contact failures and other problems. Take care under this condition.
Type Rated voltage input Operate voltage (Initial) Release voltage (Initial)
Input current (during application of rated
input voltage)
AQZ∗0∗D 12, 24V DC
Max. 5.1V DC
(Relay max. 4.0V + include diode max.
1.1V)
Min. 1.2V
(Relay max. 0.8V + include diode max.
0.4V)
Approx. 10.0mA
(Relay 7.0mA + LED 3mA)
Allowable load voltage Allowable load current
600V (DC), 600V (AC peak value) 3A
Specification Item Performance
Contact rating
Rated control capacity 3 A 250 V AC, 3 A 30 V DC
Maximum allowable contact power (resistive load) 750 VA (AC), 90 W (DC)
Maximum allowable contact voltage 250 V AC, 30 V DC
Maximum allowable contact current 3 A
Minimum load (ref. value) 100 mV 100 µA
Expected life
Electrical (resistive load)
Min. 3×10
4
: 3 A 250V AC, 3 A 30V DC
Min. 10
5
: 2 A 250V AC, 2 A 30V DC
Mechanical Min. 2×10
7
(at 180 cpm)
Possible relays
Maximum load voltage,
DC
Continuous load
current, DC
Possible relays
Maximum load voltage
(DC, AC peak value)
Continuous load current
(DC, AC peak value)
Type Part No. Type Part No.
DC only
AQZ102D 60V 1.8A
AC, DC
dual use
AQZ202D 60V 1.35A
AQZ105D 100V 1.15A AQZ205D 100V 0.9A
AQZ107D 200V 0.55A AQZ207D 200V 0.45A
AQZ104D 400V 0.30A AQZ204D 400V 0.225A
Item Specifications
Breakdown
voltage
Between input and output 2,000 Vrms for 1 min.
Between same terminals 1,000 Vrms for 1 min.
Between different terminals
(between relays, both ways)
1,500 Vrms for 1 min.
Insulation resistance Min. 100 MΩ (Using 500 V DC megger, measuring same place as breakdown voltage.)
Vibration resistance (destructive) 10 to 55 Hz at double amplitude 1 mm .039 inch
Vibration resistance (functional) 10 to 55 Hz at double amplitude 1 mm .039 inch
Shock resistance (destructive) Min. 196 m/s
2
Shock resistance (functional) Min. 98 m/s
2
Ambient temperature –20°C to +55°C –4°F to +131°F
Ambient humidity 35% to 85% R.H. (Not condensing)
Storage temperature –30°C to +80°C –22°F to +176°F (Not freezing and condensing)
Te r minal screw fasten torque 0.3 to 0.5 N·m
Coil surge absorber Diode (1A, 400V)
Cross connection protecting diode 1.5 A, inverse voltage 40 V
Unit weight Approx. 100 g 3.53 oz
All Rights Reserved © C