Datasheet
Table Of Contents
- Front cover
- Specifications
- Dimensions
- Terminals
- Standard setting-up position
- Projection distance for 16:10 aspect ratio screen
- Projection distance for 16:9 aspect ratio screen
- Calculation of the projection distance
- Shift range
- Installable angle
- List of compatible signals
- Serial connector
- Pin assignments and signal names
- Communication conditions (factory setting)
- Basic format
- Cable specifications
- Control commands
- Status request commands
- Command example
- Notes on projector placement and operation
- Direction of air intake and exhaust
- Operating the projector continuously

S P E C F I L E
PT-EZ570/EZ570L
LCD Projectors
As of July 2012
SFL12M004-2
1 5 / 1 7
Status request commands
Command:Parameter Function DescriptionCallback
QPW
QIN
QLP
QSH
QFZ
QSE
QPM
QST
Q$L:1
QTM:0
QTM:2
Main power status
Input signal status
Lamp power mode status
Shutter function status
Freeze function status
Aspect mode status
Picture mode status
Projector run time
Lamp run time
Temperature status
Off
On
Input 1 [HDMI]
Input 1 [DVI-D]
Input 1 [RGB (PC)]
Input 2 [RGB (PC)]
Input 2 [RGB (YP
BPR/YCBCR)]
Input 2 [Video]
Input 3 [component]
Input 3 [S-Video]
Input 3 [Video]
Auto
Normal
Eco 1
Eco 2
Off
On
On
Off
Normal
Full
Wide (16:9)
Zoom
Real
Custom
Normal
Full
Standard
Dynamic
Cinema
Real
00000 – 99999 hours
0000 – 9999 hours
Air intake
Panel section
000
001
HD1
DVI
RG1
RG2
CP1
VD1
CP2
SVD
VD2
2
0
3
4
0
1
0
1
0
6
2
40
5
50
0
6
STD
DYN
CIN
REA
p1p2p3p4p5
p1p2p3p4
p1p2p3p4/p5p6p7p8
*
1
p1p2p3p4/p5p6p7p8 *
1
Command example
To set the shutter function on, send the command as shown below.
ADZZ OSH : 1;ETX
ID Address
ZZ: ID ALL
Command
STX
Start
Character code 02
Parameter End
Character code 03
NOTE: When sending commands without parameters, a colon (:) is not necessary.
*
1 p1p2p3p4 = Celsius (°C), p5p6p7p8 = Fahrenheit (°F)
NOTE: If a wrong command is received, the projector will send an ER401 or ER402 command to the computer.