Datasheet
51
PM4H-W
Product types
PM4H-W
Twin timer
Type Contact arrangement Time range Part number
Rated Operating
voltage
Protective
structure
Terminal
type
Operating
mode
PM4HW-H-AC240VW
PM4HW-H-AC240VSW
PM4HW-H-DC125VW
PM4HW-H-DC125VSW
PM4HW-H-24VW
PM4HW-H-24VSW
PM4HW-H-DC12VW
PM4HW-H-DC12VSW
PM4HW-H-AC240V
PM4HW-H-AC240VS
PM4HW-H-DC125V
PM4HW-H-DC125VS
PM4HW-H-24V
PM4HW-H-24VS
PM4HW-H-DC12V
PM4HW-H-DC12VS
8 pins
Screw terminal
8 pins
Screw terminal
8 pins
Screw terminal
8 pins
Screw terminal
8 pins
Screw terminal
8 pins
Screw terminal
8 pins
Screw terminal
8 pins
Screw terminal
100 to 240V AC
48 to 125V DC
24V AC/DC
12V DC
100 to 240V AC
48 to 125V DC
24V AC/DC
12V DC
16 selectable ranges
(1s to 500h)
Relay
Timed-out
2 Form C
Cyclic
(OFF-start,
Twin)
IP65
IP50
Terminal layouts and wiring diagrams
Dimensions
mm inch
Toletance: p0.5 p.020
Pin Type
Cyclic timed-out relay contact: 2C
Screw terminal type
Cyclic timed-out relay contact: 2C
Operation
(–) (+)
N.C.
N.C.
N.O.
N.O.
Operating voltage
8
5
1
7
6
2
3
4
N.C.
N.O.
N.C.
N.O.
54321
109876
11
(–)
(+)
Operating
voltage
48
1.890
62.5
2.461
17.0
.670
6.0
.236
48
1.890
41
1.614
;44.5
1.752
17.0
.670
6.0
.236
48
1.890
48
1.890
66.5
2.618
14.5
.571
41
1.614
;44.5
;1.752
Power supply
Time-delay contact
(N.O. contact)
Time-delay contact
(N.C. contact)
Output ON-OFF
indicator
T1 T1T2
Output OFF indicator (green)
Output ON indicator (orange)
OFF set time
ON set time
:
:
T1:
T2:
All types of PM4H-W timer have multi-time range.
16 time ranges are selectable.
1s to 500h (Max. range) is controlled.
Time range
1
Scale
Time unit
0.1s to 1s
sec min hrs 10h
0.1 min to 1 min 0.1h to 1h 1.0h to 10h
5 0.5s to 5s
Control
time range
0.5 min to 5 min 0.5h to 5h 5h to 50h
10 1.0s to 10s 1.0 min to 10 min 1.0h to 10h 10h to 100h
50 5s to 50s 5 min to 50 min 5h to 50h 50h to 500h
• Screw terminal type: M3.5 • Pin type
Analog
Timers