Datasheet
50
PM4H-W
DIN48 SIZE
ANALOG MULTI-RANGE
CYCLIC TWIN TIMERS
PM4H-W
Features
• A single twin timer unit that repeats (variable) ON/OFF.
• Multiple ranges with a 0.1 s to 500 h time specification on a single unit.
• The output ON/OFF operation is indicated by red and green LED’s.
It’s easy to check the operation at a glance.
• The AC free power supply and shorter body make it easier to use.
• A new screw terminal type has been added to the conventional pin type. Wiring
can be done easily with a screwdriver.
• Compliant with UL, CSA, CE and LLOYD.
48
1.890
48
1.890
62.5
2.461
mm inch
Specifications
Type
Item
PM4H-W
100 to 240V AC, 48 to 125V DC, 12V DC, 24V AC/DCRated operating voltage
50/60Hz common (AC operating type)
5A 250V AC (resistive load)
Cyclic (OFF-start/Twin operation)
Rated frequency
Rated control capacity
1s to 500h 16 time ranges switchable (T
1, T2 time setting individually)
0.3% (power off time change at the range of 0.3s to 1h)
5% (Full-scale value)
0.5% (at the operating voltage changes between 85 to 110%)
Max. 100m (at 1A 6V DC)
Timed-out 2 Form C
2% (at 20C ambient temp. at the range of –10 to +50C +14 to 122F)
Time range
Operation time fluctuation
210
7
10
5
(at rated control capacity)
Mechanical (contact)
Electrical (contact)
85 to 110% of rated operating voltage (at 20C coil temp.)Allowable operating voltage range
–10 to +50C +14 to +122FAmbient temperature
30 to 85%RH (non-condensing)Ambient humidity
860 to 1,060hPaAtmospheric pressure
20%Ripple factor (DC type)
IP65 on front panel (using rubber gasket ATC18002) <only for IP65 type>Protective construction
120g 4.233 oz (Pin type), 130g 4.586 oz (Screw terminal type)Weight
10 to 55Hz: 1 cycle/min double amplitude of 0.25mm (10min on 3 axes)
Vibration resistance
10 to 55Hz: 1 cycle/min double amplitude of 0.375mm (1h on 3 axes)
Min. 98m/s
2
(4 times on 3 axes)
Shock resistance
Min. 980m/s
2
(5 times on 3 axes)
Functional
Destructive
Functional
Destructive
Between live and dead metal parts
Between input and output
Between contacts of different poles
Between contacts of same pole
Insulation resistance (Initial value)
2,000Vrms for 1 min Between live and metal parts
2,000Vrms for 1 min Between input and output
2,000Vrms for 1 min Between contacts of different poles
1,000Vrms for 1 min Between contacts of same pole
Breakdown voltage (Initial value)
Setting error
Voltage error
Contact resistance (Initial value)
300msMin. power off time
55C 131FMax. temperature rise
Silver alloyContact material
Temperature error
Contact arrangement
Operation mode
Approx. 10VA (100 to 240V AC)
Approx. 2.5VA (24V AC)
Approx. 1.5W (12V DC, 24V DC, 48 to 125V DC)
Rated power consumption
Rating
Time
accuracy
Note:1)
Contact
Life
Electrical
function
Mechanical
function
Operating
condition
Others
Min. 100M (At 500V DC)
Notes: 1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within 5% rip-
ple factor for DC), 20°C 68°F ambient temperature, and 1s power off time.
2) For the 1s range, the tolerance for each specification becomes ±10ms.
3) As internal components may become worn when using continuous conduction, the product should be replaced periodically.
UL File No.: E122222
CSA File No.: LR39291
Analog
Timers
09/2009