Dimensions Guide
Specification Submittal Data
Panasonic Radiation Damper
for Combustible Assemblies
Description:
Radiation damper shall be assembled with
select ENERGY STAR
®
rated ventilation fans,
fan/lights and fans with motion/condensation
sensors. Damper shall be UL and cUL listed
for wood truss assemblies and meet UL 555C
for use in 1 hour fire-rated floor/ceiling or roof/
ceiling assemblies as listed below. Damper
shall exceed National Fire Protection Agency
NFPA-90A.
Features:
• UL 555C listed for use in a 1 hour fire-rated
wood truss floor/ceiling and roof/ceiling
designs*
• 165 degree Fahrenheit fusible link.
• High-temperature, non-asbestos, reinforced
fiber thermal fabric.
• Galvanized steel frame.
• Damper sleeve allows for fan/motor access for
ongoing maintenance or framing/drywall/paint
installation staging.
• Drywall support installation after drywall
to make fan/damper assembly meet UL
Combustible Assemblies.
UL listed assembly with Panasonic
ENERGY STAR
®
models:
WhisperGreen
®
Select
™
:
FV-05-11VK1.
FV-05-11VKL1, FV-05-11VKS1,
FV-05-11VKSL1, FV-11-15VK1, FV-11-15VKL1
WhisperCeiling
®
/WhisperCeiling
®
DC
™
:
FV-05VQ5, FV-08VQ5, FV-08VQL5,
FV-08VQL6, FV-11VQ5, FV-11VQL5,
FV-11VQL6, FV-15VQ5, FV-15VQL5,
FV-15VQL6 , FV-0511VQ1, FV-1115VQ1,
FV-0511VQL1, FV-1115VQL1
WhisperSense
®
/WhisperSense
®
DC
™
:
FV08VQC5, FV08VQCL5, FV-08VQCL6,
FV-11VQC5, FV-11VQCL5, FV-11VQCL6,
FV-0511VQC1, FV-0511VQCL1
WhisperFit
®
/WhisperFit
®
EZ
™
: FV-05VF2,
FV-05VFL4, FV-05VFM2, FV-08-11VF5,
FV-08-11VFL5, FV-08-11VFM5, FV-08VF2,
FV-08VFL4, FV-08VFM2, FV-11VF2, FV-11VFL4
WhisperValue
®
/WhisperValue
®
DC
™
:
FV-0510VS1, FV-0810VSS1, FV-0510VSC1,
FV-0510VSL1, FV-0810VSSL1, FV-0510VSCL1,
FV-05VS1, FV-05VS3, FV-08VS3, FV-08VSL3,
FV-10VS1, FV-10VS3, FV-10VSL3, FV-10VS3E,
FV-10VSL3E
PC-RD05C5
Panasonic Eco Solutions North America
Eco Products Divsion
Two Riverfront Plaza
Newark, NJ 07102
us.panasonic.com/ventfans
For complete Installation Instructions visit us.panasonic.com/ventfans
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
PC-RD05C5
3-1/4"
3-9/16"
3/8"
3-9/16"
11-7/8"
3/8"
11-7/8"
11-7/8"
3-1/4"
File #: 3225-1598:100
File #: WHI-495-PSH-0177, -0178
* UL 555C classification for the following 1 hour UL Wood
Truss Assembly Ratings: L521, L528, L546, L558,
L562, L574, L576, L581, L583, L585, M509; P522,
P-533, P-538, P-545 and P-547.
See following page for Non-Combustible
Assembly application.
3-1/4"
3-9/16"
3/8"
3-9/16"
11-7/8"
3/8"
11-7/8"
11-7/8"
3-1/4"
VF17619SS1017