Datasheet
PA(D)
2
ds_61C10_en_pa: 131113D
RATING
1. Coil data
1) PA type
2) PAD type
2. Specifications
Nominal coil
voltage
Pick-up voltage
(at 20C 68F)
Drop-out voltage
(at 20C 68F)
Nominal operating
current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
Nominal operating
power
Max. allowable voltage
(at 20C 68F)
4.5V DC
70%V or less of
nominal voltage
(Initial)
5%V or more of
nominal voltage
(Initial)
26.0mA 169
120mW
120%V of
nominal voltage
5V DC 24.0mA 208
6V DC 20.0mA 300
9V DC 13.3mA 675
12V DC 10.0mA 1,200
18V DC 6.7mA 2,700
24V DC 7.5mA 3,200 180mW
24V DC 5.0mA 4,800 120mW
Nominal coil
voltage
Pick-up voltage
(at 20C 68F)
Drop-out voltage
(at 20C 68F)
Nominal operating
current
[10%] (at 20
C 68F)
Coil resistance
[10%] (at 20C 68F)
Nominal operating
power
Max. allowable voltage
(at 20C 68F)
5V DC
70%V or less of
nominal voltage
(Initial)
5%V or more of
nominal voltage
(Initial)
36.0mA 139
180mW
120%V of
nominal voltage
12V DC 15.0mA 800
18V DC 10.0mA 1,800
24V DC 7.5mA 3,200
Characteristics Item
Specifications
PA type PAD type
Contact
Arrangement 1 Form A
Initial contact resistance, max. Max. 30 m (By voltage drop 6 V DC 1A)
Contact material Au-clad AgNi type
Rating
Nominal switching capacity (resistive load) 5 A 250 V AC, 5 A 30 V DC 3 A 250 V AC, 3 A 30 V DC
Max. switching power (resistive load) 1,250 VA, 150 W 750 VA, 90 W
Max. switching voltage 250 V (AC), 110 V (DC)
Max. switching current 5 A 3 A
Nominal operating power 120 mW (5 to 24 V DC), 180 mW (24 V DC) 180 mW
Min. switching capacity (Reference value)
*1
*1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
100A 100mV DC
Electrical
characteristics
Insulation resistance (Initial)
Min. 1,000M (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA.)
Between contact and coil 2,000 Vrms for 1min. (Detection current: 10mA.)
Surge breakdown
voltage (Initial)
Between contacts and coil
*2
*2 Wave is standard shock voltage of 1.250s according to JEC-212-1981.
4,000 V
Temperature rise (at 20C 68F)
Max. 45C
(By resistive method, nominal voltage applied to the coil, nominal switching capacity.)
Operate time (at nominal voltage) (at 20C 68F) Max. 10 ms
Release time (at nominal voltage) (at 20C 68F) Max. 5 ms
Mechanical
characteristics
Shock resistance
Functional Min. 147 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Destructive Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 2.5 mm (Detection time: 10s.)
Destructive 10 to 55 Hz at double amplitude of 3.5 mm
Expected life
Mechanical Min. 210
7
(at 180 times/min.)
Electrical
3 A 250 V AC, 30 V DC Min. 110
5
operations (at 20 times/min.)
5 A 250 V AC, 30 V DC Min. 510
4
operations (at 20 times/min.) —
Conditions
Conditions for operation, transport and storage
*3
*3 Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
Ambient temperature: –40C to 70C –40F to 158F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 20 times/min.
Unit weight Approx. 3 g .15 oz
Notes: