Datasheet

18
9-3 Reector / reective tape
(
retroreective type
NX5-PRVM5□ / NX5-RM7□)
Reector RF-230 is accessory of retroreective type NX5-PRVM5□ and NX5-RM7□.
By using reector (optional) or reectivity tape (optional), small object can be detected.
However, the sensing distance would be shorter by using reflector (optional) or
reectivity tape (optional).
Designa-
tion
Model No.
Sensing
distance
Min. sensing
object
Specication
Sensor
Reector
RF-230
(Accessory)
NX5-PRVM5□ 0.1 to 5m
ø50mm
Dimension (W × H × D):
50.3mm × 59.3mm × 8.3mm
Thru-hole threads: ø3.7mm
NX5-RM7□ 0.1 to 7m
RF-210
(Optional)
NX5-PRVM5□ 0.1 to 1.5m
ø30mm
Dimension (W × H × D):
33.3mm × 12.8mm × 11mm
Thru-hole threads: ø3.4mm
NX5-RM7□ 0.1 to 2.5m
RF-220
(Optional)
NX5-PRVM5□ 0.1 to 3.5m
ø35mm
Dimension (W × H × D):
35.3mm × 42.3mm × 8.3mm
Thru-hole threads: ø3.6mm
NX5-RM7□ 0.1 to 5m
Reective
tape
RF-11
(Optional)
NX5-PRVM5□ 0.1 to 0.8m
ø30mm
Dimension (W × H × D):
30mm×8mm×0.7mm
Ambient temperature: -25 to +50ºC
Ambient humidity: 35 to 85%RH
NX5-RM7□ 0.1 to 1m
RF-12
(Optional)
NX5-PRVM5□ 0.1 to 1m
ø30mm
Dimension (W × H × D):
30mm × 25mm × 0.7mm
Ambient temperature: -25 to +50ºC
Ambient humidity: 35 to 85%RH
NX5-RM7□ 0.1 to 1.5m
<In case of RF-230>
Setting range of reector /
reective tape
Reector / reective tape
Sensor
0.1m
Reector / reective tape
Actual sensing range
of the sensor
Reector cannot be
placed in this range.
5m (NX5-RM7□ is 7m)