*3 Deviation counter clear input(CL)can be assigned only to SI7 input.
Wrong assignment will cause Err33.6 Counter clear assignment error.
*4 Command pulse inhibit input(INH)can be assigned only to SI10 input.
Wrong assignment will cause Err33.7 Command pulse input inhibit input.
Input signals (command pulse train) and their functions
Suitable interface can be chosen from two kind of interface based on the specification of command pulses.
Pulse train interface with line driver
Name Symbol
Connector
Pin No.
Description Circuit
PULSH1
20
Command pulse
input 1
PULSH2
21
SIGNH1
22
Command
direction input 1
SIGNH2
23
- Input terminal for the position command pulse. It can be selected by
setting corresponding parameters.
- Disabled in such control modes as the speed control or the torque
control, which does not require position commands.
- The maximum allowable input frequency is 500kpps.
Di-1
Output signals (Common) and their functions
Name Symbol
Connector
Pin No.
Description
Circuit
Multi-function output 1
SO1
8
Multi-function output 2
SO2
9
Multi-function output 3
SO3
10
- The function changes according to the parameter settings. See
below.
o-1