Datasheet
SX-ZSV00007 - 13 -
Motor Business Division, Appliances Company, Panasonic Corporation
6-3 Encoder Connector X3
Description
Connector Pin
No.
Symbol
Encoder power supply output
1 E5V
2
E0V (*
Remark 1)
――
3
――
4
――
Encoder Signal input/out put
(Serial Signal)
5 PS
6 /PS
Frame ground shell FG
* Remark 1) The E0V of the encoder power supply output is connected with the control circuit ground of the
connector
.
6-4 Motor and Power Connector X4
Size B,C of 220 V System
Terminal
Symbol
Terminal Name
Description
X4
U(red)
Motor connection
Connect each phase of the motor winding.
U: U phase V: V phase W: W phase
V(gray)
W(black)
B1(gray)
Regen. resistor
connection
If the drive gets over regeneration alarm, connect an external regen resistor
(prepared by customer) between B1 and B2.
B2(gray)
L1C(red)
Control power
supply input
220 V
Single phase 220~240 V
+ 5%
, 50/60 Hz input
L2C(red) - 10%
L1(black)
Main power supply
input
220 V
Single phase 220~240 V
+ 5%
, 50/60 Hz input
L2(black) - 10%
Earth Earth terminal for grounding.
Please select the ferrule length between 12 mm ~ 15 mm. Short ferrule pins can not be fixed during the
insertion. Ferrule pin of DNH4 -112 made in DINKEL (4 mm diameter) is recommended.
※Tighten the fixing screws to the case at screw torque of 0.4~0.6 N·m or less.