Datasheet
SX-ZSV00007 - 8 -
Motor Business Division, Appliances Company, Panasonic Corporation
② Changes in the distribution of the input signal using the Situations
Situations the input signal distribution changes,Follow the following parameters to change
.
Classification No. Classification
Setting range Flats Function
4 00
SI1 Input selection
0~00FFFFFFh
-
SI1 Input only assigned setting:
This parameter is used to set the hexadecimal
representation of the benchmark.
000000**h
「**」Part of the set the function designation.
Please refer to the back of the function designation form.
Function designation also includes theoretical setting.
Cases) this pin is set to DIV1╴ a type wish to take the
occasion,Please set 0000000Ch.
4 01
SI2 Input selection
0~00FFFFFFh
-
SI2 assigned function of the input setting.
setting the same methods and Pr4.00.
4 02
SI3 Input selection
0~00FFFFFFh
-
SI3 assigned function of the input setting.
setting the same methods and Pr4.00.
4 03
SI4 Input selection
0~00FFFFFFh
-
SI4 assigned function of the input setting.
setting the same methods and Pr4.00.
4 04
SI5 Input selection
0~00FFFFFFh
-
SI5 assigned function of the input setting.
setting the same methods and Pr4.00.
4 05
SI6 Input selection
0~00FFFFFFh
-
SI6 assigned function of the input setting.
setting the same methods and Pr4.00.
Function of designations table
Signal Name
Symbol
Setpoint
a type b type
Invalid - 00h Not set
Positive overtravel limit POT 01h 81h
Negative overtravel limit NOT 02h 82h
SUV-ON input SRV-ON 03h 83h
Alarm clear A-CLR 04h Not set
(Setting prohibited) - 05h 85h
Gain switch GAIN 06h 86h
Deviation counter clear CL 07h Not set
Command pulse inhibition INH 08h 88h
Torque limit switch input TL-SEL 09h 89h
Anti-vibration switch 1
VS-SEL1 0Ah 8Ah
Anti-vibration switch 2
VS-SEL2 0Bh 8Bh
Command scaling switch 1
DIV1 0Ch 8Ch
Command scaling switch 2
DIV2 0Dh 8Dh
(Setting prohibited) -
0Eh~13h 8Eh~93h
Alarm input force E-STOP 14h 94h
(Setting prohibited) - 15h 95h
Note:
・Please do not setting table in a setting other than the setting value. The Situations has been set, Occur Err33.2
「I/F input function designation exception 1」,Err33.3「I/F input function designation exception 2」.When there are set
to table (Prohibition settings), the protection function does not effect, Since the function of the input signal will not
work, set to invalid (00h).
・The same function can not be assigned to multiple signals. The Situations has been set,
Occur Err33.0「I/F input abnormal assigned repeat 1」、Err33.1「I/F input abnormal assigned repeat 2」.
・Deviation counter clear (CL) Only with SI13 input distribution. If assigned to this other occasions, Occur Err33.6
「Clear the cumulative assigned abnormalities」
.