Datasheet

SR-ZSV00039 30
Motor Business Unit, Appliances Company, Panasonic Corporation
7)Basic gain parameter settings table
Gain 1 Gain 2
Pr1.00 Pr1.01 Pr1.02
Pr1.04
*2 Pr1.05 Pr1.06 Pr1.07
Pr1.09
*2
Stiffness
Position
[0.1/s]
Speed
[0.1 Hz]
Velocity
integral
[0.1 ms]
Torque
[0.01 ms]
Position
[0.1/s]
Speed
[0.1 Hz]
Velocity
integral
[0.1 ms]
Torque
[0.01 ms]
A4 Series
stiffness
setting
(Reference)
*1
0 20 15 3700 1500 25 15 10000
1500
1 25 20 2800 1100 30 20 10000
1100
2 30 25 2200 900 40 25 10000
900
3 40 30 1900 800 45 30 10000
800
4 45 35 1600 600 55 35 10000
600
5 55 45 1200 500 70 45 10000
500
6 75 60 900 400 95 60 10000
400
7 95 75 700 300 120 75 10000
300
8 115 90 600 300 140 90 10000
300 0
9 140 110 500 200 175 110 10000
200
10 175 140 400 200 220 140 10000
200
11 320 180 310 126 380 180 10000
126 1
12 390 220 250 103 460 220 10000
103 2
13 480 270 210 84 570 270 10000
84 3
14 630 350 160 65 730 350 10000
65 4
15 720 400 140 57 840 400 10000
57 5
16 900 500 120 45 1050 500 10000
45 6
17 1080 600 110 38 1260 600 10000
38 7
18 1350 750 90 30 1570 750 10000
30 8
19 1620 900 80 25 1880 900 10000
25 9
20 2060 1150 70 20 2410 1150 10000
20 10
21 2510 1400 60 16 2930 1400 10000
16 11
22 3050 1700 50 13 3560 1700 10000
13 12
23 3770 2100 40 11 4400 2100 10000
11 13
24 4490 2500 40 9 5240 2500 10000
9 14
25 5000 2800 35 8 5900 2800 10000
8
26 5600 3100 30 7 6500 3100 10000
7 15
27 6100 3400 30 7 7100 3400 10000
7
28 6600 3700 25 6 7700 3700 10000
6
29 7200 4000 25 6 8400 4000 10000
6
30 8100 4500 20 5 9400 4500 10000
5
31 9000 5000 20 5 10500
5000 10000
5
*1 Hardness settings of A4 series refers to the setting values (0 to 15) of A4 series parameter Pr22 "Real-time auto tuning machine hardness
selection."
*2 For 2500[p/r] encoder, a value is limited to 25, a maximal value.