Datasheet

FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
WIRE-
SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PARTICULAR
USE
SENSORS
EX-F70 /
EX-F60
Selection
Guide
HD-T1
M-DW1
Wafer
Detection
EX-F1
LX-100
FZ-10
NA1-11
Metal-sheet
Double-feed Detection
GD
Other
Products
Liquid Leak
Detection
Liquid Level
Detection
Color Mark
Detection
Small / Slim
Object Detection
LX-100
Color Mark
Detection
755
Digital Mark Sensor LX-100 SERIES
I/O circuit diagram I/O circuit diagram
Users’ circuitInternal circuit
D
1
D
2
Color code of cable type /
mating cable for plug-in connector type
(Brown) +V
(Black) Output 1
50 mA max. (Note 1)
50 mA max. (Note 1)
(White) Output 2 (Note 2)
Z
D
1
Z
D
2
(Blue) 0 V
Tr
1
Tr
2
10 kΩ
(Pink) Teaching input
*1
+5 V
Load
Load
3
1
Terminal No. of plug-in connector type
12 to 24 V DC
± 10 %
+
4
2
Sensor circuit
D
2
10 kΩ
Users’ circuitInternal circuit
Sensor circuit
Z
D
1
Z
D
2
(Brown) +V
(Pink) Teaching input
D
1
Tr
1
Tr
2
50 mA max. (Note 1)
50 mA max. (Note 1)
(Black) Output 1
(Blue) 0 V
(White) Output 2
(Note 2)
0 V
*1
Color code of cable type /
mating cable for plug-in connector type
12 to 24 V DC
± 10 %
+
4
1
Load
Load
Terminal No. of plug-in connector type
3
2
Notes: 1) The current of the plug-in connector type LX-101-Z is 100 mA max.
2)
The output 2 is not incorporated to the plug-in connector type LX-101-Z.
Notes: 1)
The current of the plug-in connector type LX-101-P-Z is 100 mA max.
2)
The output 2 is not incorporated to the plug-in connector type LX-101-P-Z.
1*
I/O CIRCUIT AND WIRING DIAGRAMS
Non-voltage contact or PNP transistor
or
0 V
Teaching input
High: +4 V to +V (sink current: 3 mA or less)
Low: 0 to +0.6 V, or open
Teaching is carried out at the High.
NPN
High5VV
Low02V0.5mA
Low
Non-voltage contact or NPN transistor
or
+V
Teaching input
High: 5 V to +V, or open
Low:
0 to +2 V(source current: 0.5 mA or less)
Teaching is carried out at the Low.
Connector pin layout of plug-in connector type
Connector pin No.
Description
1
+V
2
Teaching input
3
0 V
4
Output
L
D
W
(Unit: mm in)
Setting distance L
(Note 1)
Spot size (Note 2)
Width (W) Length (D)
7 0.276 2.0 0.079 5.5 0.217
8 0.315 1.7 0.067 5.5 0.217
9 0.354 1.2 0.047 5.3 0.209
10 0.394 1.0 0.039 5.0 0.197
11 0.433 1.3 0.051 5.0 0.197
12 0.472 1.5 0.059 5.0 0.197
13 0.512 2.0 0.079 5.0 0.197
SPOT SIZE CHARACTERISTICS (TYPICAL)
Notes: 1) Setting distance “L” represents the distance from
the lens surface to the sensing object.
2) Examples only meant for use as a guideline.
Symbols … D
1
, D
2
: Reverse supply polarity protection diode
Z
D1,
Z
D2
: Surge absorption zener diode
Tr
1
, Tr
2
: NPN output transistor
Symbols … D
1
, D
2
: Reverse supply polarity protection diode
Z
D1,
Z
D2
: Surge absorption zener diode
Tr
1
, Tr
2
: PNP output transistor
LX-101(-Z)
NPN output type
LX-101-P(-Z)
PNP output type
1*