Datasheet
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
LASER
MARKERS
PARTICULAR
USE SENSORS
EX-F70 /
EX-F60
Selection
Guide
Wafer
Detection
Metal-sheet
Double-feed Detection
Other
Products
Liquid Leak
Detection
Liquid Level
Detection
Color Mark
Detection
Small / Slim
Object Detection
HD-T1
M-DW1
EX-F1
LX-100
FZ-10
NA1-11
GD
LX-100
Color Mark
Detection
Digital Mark Sensor LX-100 SERIES
752
Timer period
Timer mode
Turn mode (Note 5)ECO mode (Note 4)
Key lockDisplay mode
2nd digit 3rd digit 4th digit1st digit
Display
1 ms
2 ms
5 ms
10 ms
20 ms
50 ms
100 ms
200 ms
500 ms
non
OFF-delay
ON-delay
non
OFF-delay
ON-delay
non
OFF-delay
ON-delay
OFF
ON
OFF
ON
OFF
ON
OFF
ON
FINE
COARSE
FINE
COARSE
FINE
COARSE
FINE
COARSE
FINE
COARSE
FINE
COARSE
FINE
COARSE
FINE
COARSE
L-ON
D-ON
L-ON
D-ON
L-ON
D-ON
Consistent-ON
Inconsistent-ON
OFF
ON
OFF
ON
Mark mode (green)
Mark mode (blue)
Mark mode (red)
Color mode
Standard
Percent display
(Note 3)
Full lock
(All operations disabled)
RUN teaching
(Teaching only enabled)
RUN adjust
Threshold value
adjustment only enabled
DisplayDisplayDisplay
Sensing mode (light source color)
Operation mode (Note 1)
Sensing (Note 2)
●
When in RUN mode, press the MODE
key for at least 2 sec. to display the
direct code. (Remove your finger from
the MODE key and the direct code will
disappear.)
( )
Direct code table (D-Code)
The sensor setting modes can be verifi ed by a 4-digit
code (D-Code). The table below shows a list of all
available codes.
Notes: 1) In Mark mode, L-ON / D-ON is automatically set in the sensor. For example, with 2-level teaching, press the ON key at the targeted mark and
press the OFF key at the base (non-mark area). When doing so, the operator does not have to consider L-ON / D-ON.
2) Sensing accuracy can be set to either FINE (standard) or COARSE.
3) The percent display is only enabled in mark mode.
4) ECO mode is a function that reduces power consumption by turning off the digital display in the event no button operations are made for a
predetermined time (approx. 10 sec. or more) in RUN mode. Press any button to turn the digital display on again.
5) The turn mode is a function that reverses the digital display making it easily viewed in the event the sensor installation renders the display up-side-down.
* Default setting: D-code “ ”.
Super simple teaching
Press the ON button at the targeted mark.
We provided an example of the most basic setting
method “2-level teaching”.
External teaching possible
Teaching is possible by external input using the
operation panel or touch panel even for color mark
sensors whose position within the equipment is out of
reach. Models can be easily interchanged.
Mode selection
Press MODE key and select TEACH mode.
Sensing
Teaching complete. The optimal LED is
automatically selected and the sensor
automatically returns to RUN mode.
Teaching
1
2
Display showing
complete settings
Align the spot on the mark and press the ON key.
Align the spot onto the base (non-mark area) and press the OFF key.
* The order can be reversed.
1
2
2-level teaching and full-auto teaching possible
Mark mode
1-level teaching possible
Color mode
Other teaching methods
Full-auto teaching: In Mark mode, teaching is effectuated
without stopping the sensing object.
1-level teaching: In Color mode, the color detected is aligned
by the spot and teaching is effectuated.
•
•
Compact design for signifi cant space savings
High precision sensing and multiple functions provided
all in a compact W57 × D24 × H38 mm
W2.244 ×
D0.945 × H1.496 in
body.
Cable and plug-in connector
types are available
depending on the
equipment used.
These sensors can
be easily introduced
to already existing
facilities.
Key lock function
The key lock function enables input operation control
that prevents mistaken changes in the sensor settings.
Also possible are minute settings such as “RUN adjust”,
allowing threshold value adjustment only, and “RUN
teaching”, allowing teaching operation only.
If setting the sensor to “RUN adjust” or “RUN teaching”,
adjustments and teaching is possible with the sensor left
in RUN mode.
57 mm
2.244 in
24 mm
0.945 in
38 mm