Head-separated Dual Display Digital Pressure Sensor DPC-100 SERIES DPH-100 SERIES
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Equipped with independent two output and three output modes
Equipped with auto-reference / remote zero-adjustment functions,
More precise pressure management is possible with a minimum of effort
Equipped with two independent comparative outputs, and separate sensing modes can be selected for each of them.
Two comparative outputs are provided, so that one of the outputs can be used as a warning output. In addition, if an
output is not being used, it can be disabled.
With remote zero-adjustment function applied
20
15
0
-5
OK
30
Remote zero-adjustment input
25
Time
–5
The display is forced to “0”, and only the
filling pressure drop range is displayed.
0
When remote zero-adjustment input is applied, the reference pressure is
forced to “0”.
If the reference pressure changes to “20” or “40”, the remote zero-adjustment
input adjusts the reference pressure to “0” every time the reference pressure
changes, so any variation in the filling pressure can be ignored.
Without auto-reference and remote zero-adjustment functions
Comparative output: Window comparator mode
Hi-1
30, Lo-1
25
Fixed set value
0
30
40
OK
NG?
NG?
25
20
Leak threshold level
Variation in the filling pressure
15
Time
Pressure
Trial 1
Trial 2
Trial 3
Because the threshold level is fixed for conventional pressure
sensors, changes in the reference pressure result in wrong
decisions.
Comparative output: Window comparator mode
Hi-1
0, Lo-1
5
Sets the absolute threshold level
With auto-reference function applied
When auto-reference input is applied, the reference pressure “30” is
added to the threshold level. If the reference pressure changes to “20”
or “40”, the auto-reference input compensates for this every time by
changing the threshold level, so any variation in the filling pressure can
be ignored.
20
15
0
-5
OK
Comparative output: Window comparator mode
Hi-1
0, Lo-1
5
30
Auto-reference input
The display remains at “30” and
only the threshold level is changed.
25
Time
Pressure
Trial 1
Auto-reference input value
Sets the absolute threshold level
Threshold level after applying
auto-reference input
Threshold level before applying
auto-reference input
Threshold level after applying
remote zero-adjustment input
Threshold level before applying
remote zero-adjustment input
Trial 1
Displayed when remote zero-
adjustment input is applied
Pressure
If the reference pressure of the device changes, the auto-
reference function partially shift the comparative output
judgment level by the amount that the reference pressure
shifts, and the remote zero-adjustment function can
resetthedisplayvaluetozeroviaexternalinput.These
functions are ideal for places where the reference pressure
uctuateswildly,orwherenesettingsaredesired.
This mode is used for comparative output ON / OFF control.
EASY mode
H (Hysteresis)
H: Fixed
P
0
ON
OFF
Comparative
output
1
Pressure
Notes: 1)
Hysteresis can be fixed to one of eight different levels.
2) “ ” appears in the sub display for
comparative output 1, and “ ” appears for
comparative output 2.
Lo
Hi
0
ON
OFF
H (Hysteresis)
H: 1 digit or more
This mode is used for setting comparative output
hysteresis to the desired level and for carrying out ON /
OFF control.
Hysteresis mode
2
Pressure
Comparative
output
Note: “ ” or “ ” appears in the sub display for
comparative output 1, and “ ” or “ ”
appears for comparative output 2.
H (Hysteresis)
H: Fixed
H (Hysteresis)
Lo
Hi
0
ON
OFF
This mode is used for setting comparative output ON
and OFF at pressures within the setting range.
Window comparator mode
3
Notes: 1)
Hysteresis can be fixed to one of eight different levels.
2) “ ” or “ ” appears in the sub display
for comparative output 1, and “ ” or
“ ” appears for comparative output 2.
Pressure
Comparative
output
Vacuum breakdown can also be checked during suction applications!
Reference pressure alarm output is possible during reference pressure checking!
Comparative output 1
EASY mode
Comparative output 2
EASY mode
ON
OFF
ON
OFF
–100 kPa
0 kPa
P-1 0 kPa P-2
Suction checking
Vacuum breakdown checking
Comparative output 1
hysteresis mode
Comparative output 2
EASY mode
ON
OFF
ON
OFF
Lo-1 Hi-1 P-2
Alarm output
Reference
pressure
checking
Comparative output 1
EASY mode
Comparative output 2
EASY mode
ON
OFF
ON
OFF
–100 kPa
0 kPa
P-1 0 kPa P-2
Suction checking
Vacuum breakdown checking
Comparative output 1
hysteresis mode
Comparative output 2
EASY mode
ON
OFF
ON
OFF
Lo-1 Hi-1 P-2
Alarm output
Reference
pressure
checking