Datasheet
Head-separated Dual Display Digital Pressure Sensor DPC-100 SERIES DPH-100 SERIES
778
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
3-color display lets you view the controller status at a glance
Copy function reduces man-hours and human error
The main display color switches between green and red in accordance with the ON / OFF status of output during
RUN mode. In addition, the display always appears orange while setting is in progress, so that the status of the
controller can be viewed at a glance.
Controllers can be connected to a master controller one by one, and a copy of the setting details for the master
controller can be transmitted as data to the slave controllers. If making the same settings for multiple controllers, this
prevents setting errors from occurring with the other controllers and also reduces the number of changes required to
instruction manuals when equipment designs are changed.
While setting is in progress
Orange while
setting is in progress.
RUN
Display in red or
green depending
on output ON /
OFF.
MENU SETTING mode
RUN mode
PRO mode
or
Details transmitted
Details copied
Details received
+V
0 V
Comparative output 1
External input
+V
0 V
Comparative output 1
External input
* Other wires are not connected.
Power supply
Slave controllerMaster controller
Copying via wiring
Sensor head auto-recognition
The controller will automatically recognize sensor heads when they are connected, even for sensor heads with
different rated pressure ranges. There is no need to use the controller to change settings.
±100 kPa
+1 MPa
–101 kPa
DPH-101□
DPH-102□
DPH-103□
Compound pressure
Positive pressure
Vacuum pressure
Initial setting not needed
Auto-recognition
Remote zero-adjustment input
Auto-reference input
Analog voltage output
1 to 5 V
Analog current output
4 to 20 mA
Selection
Comparative output 1
Comparative output 2
Selection
Inputs Outputs
1 model to suit a wide variety of applications
DPC-100 original functions