Datasheet

MENU SETTING mode
•If the mode selection key is pressed and held for 2 sec.
in RUN mode, the mode will switch to MENU SETTING
mode.
•If the mode selection key is pressed while a setting
is being made, the mode will switch to RUN mode. In
this case, the settings that have been changed will be
entered.
Setting item Description
Comparative output 1
output mode setting
Sets the output mode for comparative output 1.
Comparative output 2
output mode setting
Sets the output mode for comparative output 2.
Analog voltage / current
output selection
Selects analog voltage output or analog current
output.
Externalinputselection
Selects auto-reference function, or remote zero-
adjustment function.
NO / NC selection
Normally open (NO) or normally closed (NC)
can be selected.
Response time setting
Sets the response time.
The response time can be selected from 0.5 ms,
1 ms, 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms,
250 ms, 500 ms, 1,000 ms and 5,000 ms.
Display color switching
for main display
Allows the color for the main display to be
changed.
The colors can be set to “red / green” or “green /
red” to correspond to ON / OFF output, or it can
bexedat“red”or“green”allthetime.
Unit switching Pressure unit can be changed.
PRECAUTIONS FOR PROPER USE
RUN mode
•This is the normal operating mode.
Setting item Description
Threshold value
setting
The threshold values for ON / OFF operation can
be changed directly by pressing the increment
key (UP) and the decrement key (DOWN).
Zero-adjustment
function
This forces the pressure value display to be
reset to zero when the pressure port is open on
the atmospheric pressure side.
Key lock function Stops key operations from being accepted.
Peak hold /
bottom hold function
Displays the peak value and bottom value for
uctuatingpressure.Thepeakvalueappearsin
the main display, and the bottom value appears
in the sub display.
PRO mode
•If the mode selection key is pressed and held for 5 sec.
in RUN mode, the mode will switch to PRO mode.
•If the mode selection key is pressed while a setting
is being made, the mode will switch to RUN mode. In
this case, the settings that have been changed will be
entered.
Setting item Description
Sub display switching
Changes the information in the sub display during
RUN mode operation to the current pressure unit,
number and desired alphanumeric display.
Display refresh rate
switching
Changes the display refresh rate for the
pressure value displayed in the main display.
Hysteresisxvalue
switching
Sets the hysteresis for EASY mode and window
comparator mode. (8 steps)
Linked display color
switching
Allows the display color for the main display to
be switched in line with the output operation for
comparative output 1 or comparative output 2.
Externalinputrelation
selection
Thesettingcontentssetattheexternalinput
selection in MENU SETTING mode can be
shifted to correspond to either comparative
output 1, 2 or 1 / 2.
ECO mode setting
Allows power consumption to be reduced by
dimming the display or turning it off.
Setting check code
Allows the setting details to be checked via
codes. (Refer to below)
Setting copy mode
Allows the setting details for the master
controller to be copied to slave controllers.
Reset setting Resets the settings to the factory settings.
Table of codes
Code
1st digit 2nd digit 3rd digit 4th digit
Comparative output 1
output mode
NO / NC
selection
Comparative output 2
output mode
NO / NC
selection
Analog
output
Threshold
display
Externalinput
EASY
NO OFF
Analog
voltage
output
Threshold value 1
OFF
NC
EASY
NO
Threshold value 2
Auto-
reference
Comparative output 1
Hysteresis
NO NC
Threshold value 3
Comparative output 2
NC
Hysteresis
NO
Threshold value 4
Comparative output
1 / 2
Window
comparator
NO NC
Analog
current
output
Threshold value 1
Remote
zero-
adjustment
Comparative output 1
NC
Window
comparator
NO
Threshold value 2
Comparative output 2
NC
Threshold value 3
Comparative output
1 / 2
Threshold value 4
Code
5th digit 6th digit 7th digit 8th digit
Displayed color of
the main display
Displayed color
relation
Response time
Unit selection
(Note)
Display
refresh rate
Eco mode
Red when ON
Comparative output 1
0.5 ms MPa
250 ms
OFF
Comparative output 2
1 ms kPa STD
Green when ON
Comparative output 1
2.5 ms kgf/cm
2
FULL
Comparative output 2
5 ms bar
500 ms
OFF
Always red
Comparative output 1
10 ms psi STD
Comparative output 2
25 ms mmHg FULL
Always green
Comparative output 1
50 ms inHg
1,000 ms
OFF
Comparative output 2
100 ms
STD
250 ms
FULL
500 ms
1,000 ms
5,000 ms
Note: When positive pressure type of the pressure sensor head is connected
to the controller for use inside Japan, “ ” (MPa) or “ ” (kPa) is
displayed. When compound pressure type or vacuum pressure type is
connected, only “ ” (kPa) is displayed.
Refer to p.1472 for general precautions.
Head-separated Dual Display Digital Pressure Sensor DPC-100 SERIES DPH-100 SERIES
788
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS