Datasheet

Wiring
•Make sure that the power supply is off while wiring.
•Verify that the supply voltage variation is within the
rating.
•If power is supplied from a commercial switching
regulator, ensure that the frame ground (F.G.) terminal of
the power supply is connected to an actual ground.
•In case noise generating equipment (switching regulator,
inverter motor, etc.) is used in the vicinity of this
sensor, connect the frame ground (F.G.) terminal of the
equipment to an actual ground.
•Do not run the wires together with high-voltage lines or
power lines or put them in the same raceway. This can
cause malfunction due to induction.
•Incorrect wiring will cause problems with operation.
Connection
•Do not apply stress directly to the connection cable
leader or to the connector.
Mounting
•When tightening the controller to the controller mounting
bracket
MS-DP1-6
(optional), use a tightening torque of
0.5 N·m or less.
•Useahexagonalwrenchtoinstall
sensor head. For the tightening torque,
refer to the following diagram. If
excessivetighteningtorqueisapplied,
the pressure port of the sensor head or
the M5 male screw of the commercial
coupling will get damaged. In case of
R1/8 male thread type, wrap sealing
tape around the coupler when
connecting to prevent leakage.
Piping
Others
•Use within the rated pressure range.
•Donotapplypressureexceedingthepressure
withstandability value. The diaphragm will get damaged
and correct operation shall not be maintained.
•Do not use during the initial transient time (controller: 0.5
sec.approx,sensorhead:50msapprox.)afterthepower
supply is switched on.
•Avoid dust, dirt, and steam.
•Take care that the sensor does not come in direct
contact with water, oil, grease, or organic solvents, such
as, thinner, etc.
•Do not insert wires, etc., into the pressure port. The
diaphragm will get damaged and correct operation shall
not be maintained.
•Do not operate the keys with pointed or sharp objects.
•The
MS-DP1-2
panel mounting bracket (optional) and
the
MS-DP1-3
front protection cover (optional) are also
available.
Front protection cover
MS-DP1-3 (Optional)
Panel mounting bracket
MS-DP1-2 (Optional)
PRECAUTIONS FOR PROPER USE
Part description
Main display
Sub display
Set value DOWN key
Set value UP key
Mode selection key
Output 1 operation indicator
Output 2 operation indicator
Sensor head
cable
Release lever
<Connector of sensor head cable>
e-CON: 1473562-4
[Manufactured by Tyco Electronics Japan G.K.]
Controller mounting
bracket
MS-DP1-6 (Optional)
M3 (length 6 mm 0.236 in)
screws with washers
Accessory for
MS-DP1-6
( )
Pressure port
Hexagonalwrench(boltwidth)
Tightening torque
R1/8 male thread
5 mm 0.197 in 9.8 N·m or less
M3 male thread
3 mm 0.118 in
0.8 N·m or less
M5 male thread 1.5 N·m or less
Hexagonal
wrench
<
Connector of connector attached cable
>
Housing: PAP-06V-S
[Manufactured by J.S.T Mfg. Co. Ltd.]
Release
lever
Connector
attached cable
(CN-66A-C□)
•Never use this product as a sensing device
for personnel protection.
•In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
•The
DPH-100
series is designed for use
with air and non-corrosive gas. It cannot
be used with liquid or corrosive and
inammablegases.
Refer to p.1472 for general precautions.
787
Head-separated Dual Display Digital Pressure Sensor DPC-100 SERIES DPH-100 SERIES
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS