Datasheet

28
Features
r Double insulation
r 30mm width
r Casing made of plastic
r Visible operation.
r Able to switch strong currents (10A conventional
thermal current).
r Electrically separated contacts.
r Precise operating points (consistency).
r Immune to electromagnetic disturbances.
r Degree of protection: IP67
r Standard cable length 1m*
MEP1G series
Certi cations - Approvals UL (upon request)
Ambient temperature
– during operation °C – 25 ... + 70
– for storage °C – 40 ... + 70
Mounting positions All positions are authorised
Protection against electrical shocks (acc. to IEC 536) Class II
Degree of protection (according to IEC 529 and EN 60 529) IP67
Degree of protection (according to UL50) Type 1 enclosure
(“indoor use only”)
Electrical Data
Rated insulation voltage U
i
- according to IEC 947-1 and EN 60-947-1 400V (pollution degree 3) (250V for M12 connector)
- according to UL 508 and CSA C22-2 n° 14 B 300, R 300
Rated impulse withstand voltage U
imp
kV 4
(according to IEC 947-1 and EN 60 947-1)
Conventional free-air thermal current I
th
A 5 (4A for M12 connector)
(according to IEC 947-5-1) s < 40 °C
Short-circuit protection A 6
U
e
< 500V a.c. - gG (gl) type fuses
Rated operational current
I
e
/ AC-15 (according to IEC 947-5-1) 24V - 50/60Hz A 5.0
120V - 50/60Hz A 3.0
240V - 50/60Hz A 1.5
I
e
/ DC-13 (according to IEC 947-5-1) 24VDC A 1.1
125VDC A 0.22
250VDC A 0.1
Switching frequency Cycles/h 3600
Load factor 0.5
Resistance between contacts 25
Mechanical durability 10 millions of operations
* For other cable inlets and cable lengths, please contact your local sales office.
General technical data
Plastic casing
Devices conform with international IEC 947-5-1
and European EN 60 947-5-1 standards
Standards