Datasheet
35
Features
r Double Insulation
r 30mm width
r Casing made of metal
r Visible operation
r Able to switch strong currents (10A conventional
thermal current)
r Electrically separated contacts
r Precise operating points (consistency)
r Immune to electromagnetic disturbances
r Degree of protection: IP67
r Standard cable length 1m*..
Certi cations - Approvals UL (upon request)
Ambient temperature
– during operation °C – 25 ... + 70
– for storage °C – 40 ... + 70
Mounting positions All positions are authorised
Protection against electrical shocks (acc. to IEC 536) Class I
Degree of protection (according to IEC 529 and EN 60 529) IP67
Degree of protection (according to UL50) Type 4 - 4X - 6 enclosure
(“outdoor use - raintight - water
tight corrosion resistant”
Electrical Data
Rated insulation voltage U
i
- according to IEC 947-1 and EN 60-947-1 400V (pollution degree 3) (250V for M12 connector)
- according to UL 508 and CSA C22-2 n° 14 B 300, R 300
Rated impulse withstand voltage U
imp
kV 4
(according to IEC 947-1 and EN 60 947-1)
Conventional free-air thermal current I
th
A 5 (4A for M12 connector)
(according to IEC 947-5-1) s < 40 °C
Short-circuit protection A 6
U
e
< 500V a.c. - gG (gl) type fuses
Rated operational current
I
e
/ AC-15 (according to IEC 947-5-1) 24V - 50/60Hz A 5.0
120V - 50/60Hz A 3.0
240V - 50/60Hz A 1.5
I
e
/ DC-13 (according to IEC 947-5-1) 24VDC A 1.1
125VDC A 0.22
250VDC A 0.1
Switching frequency Cycles/h 3600
Load factor 0.5
Resistance between contacts mΩ 25
Mechanical durability 10 millions of operations
* For other cable inlets and cable lengths, please contact your local sales office.
General technical data
Metal casing
Devices conform with international IEC 947-5-1
and European EN 60 947-5-1 standards
Standards
35