Datasheet

No. SX-DSV03025 - 23 -
Motor Business Unit, Panasonic Corporation
6-6 External feedback device connector X5
Name
Connector
pin No
Description
Power supply output for external scale
1 EX5V (*Note 2) (*Note 3)
2 EX0V (*Note 1)
External scale signal input / output
(serial signal)
3 EXPS
4 /EXPS
External scale signal input
(A / B / Z phase signal)
5 EXA
6 /EXA
7 EXB
8 /EXB
9 EXZ
10 /EXZ
Frame ground shell FG
Note 1) The E0V of the external scale power output is connected with the control circuit ground linked to the
connector X4 .
Note 2) EX5V power supply output for external scale is rated at 5.2 V ± 5% and 250 mA at maximum. To use an
external scale with a current consumption higher than that, a preparation of an external power supply is
required. Some external scales may take longer time in initialization after turning on the power.
Note 3) In case an external power supply is used for the external scale, make sure that the EX5V pin is open and no
external power is supplied to the EX5V pin.