Datasheet
MAC-I limit switches specifications & accessoiries
Operating keys
for MA150/160
Description Bent key Flat key Bent key Flat Key
Shock
absorbing
bent key
Shock
absorbing
flat key
Adjustable
joint key
Centre distance
fixing holes
22mm 22mm 13mm 13mm 15mm 15mm 40mm
Order code T83 T84 T85 T86 T87 T88 T90
You can find further information on our homepage: www.panasonic-electric-works.com
Copyright©2012•PrintedinGermany
6105euen09/12
MOR 05
OCC 08
FUN 05
RED 05
Type
MAC-I MAC-I MAC-I MAC-I MAC-I MAC-I
MA 150/160 SLC SLF SLZ MA-R MD-R
limit switch with
operating keys
limit switch
with shaft lever
limit switch
with pull wire
limit switch
with steel lever
limit switch with
pull button reset
limit switch with
pull button reset
Voltage max.
400V
Permanent current
10A
Rated operational current
(acc. to IEC 947-5-1)
(AC 15) 24V-10A; 230V-3,1A; 380V-1,9A
(DC 13) 24V-2,8A; 250V-0,27A
Standards
CE-UL/CSA
Protection class (according
to IEC 529 and EN 60 529)
IP 65/66
Contact configuration
1NO + 1NC
2NC
Operating temperature
range
-25°C to 70°C
Mech. operational life -
number of switching cycles
1 x 10
7
Electr. operational life -
number of switching cycles
1 x 10
5
Electrical connection
PG13.5 or 1/2”NPT or PG11 or M16x1.5 or M20x1.5
Specifications
Accessories
Rope clamp Rope Ø 5mm Stay bolt Rope eye