Datasheet

LC2H
80
SPECIFICATIONS
Item Descriptions
Rating
Rated operating voltage 24 V DC
Rated power consumption Max. 1.5 W
Rated control capacity 100 mA 30 V DC
Input mode Addition/Subtraction (selectable by front switch)
Max. counting speed 30 Hz/5 kHz (selectable by slide switch on side)
Counting input
Min. input signal width: 16.7 ms at 30 Hz/0.1 ms at 5 kHz,
ON time : OFF time = 1 : 1
Reset input Min. input signal width: Min. 30 ms
Input signal
Non-voltage input using contacts or open-collector connection
Input impedance; when shorted: Max. 1 k, when open: Min. 100 k
Residual voltage: Max. 2 V
Output mode
Maintain output/hold count Maintain output/over count
One shot/over count One shot/recount
(Selectable by front switch)
Display method
7-segment LCD
(Switch between red and green for backlight, and between lit and ashing for count up.)
Digit
9999999 to 99999999 (7 digits to +8 digits)
(0 to 99999999 for preset value)
Memory EEP-ROM (Overwriting times: 1.0 × 10
5
operations or more)
Contact arrangement 1 Form A (Open collector)
Electrical life (contact) 1.0 × 10
7
operations (at rated control voltage)
Electrical
Allowable operating voltage range 85 to 110% of rated operating voltage
Break down voltage (Initial value) Between input and output: 1,500 V AC, for 1 min.
Insulation resistance (Initial value) Between input and output: 100 M (at 500 V DC)
Mechanical
Functional vibration resistance 10 to 55 Hz (1 cycle/min), Single amplitude: 0.15 mm 0.006 inch (10 min. on 3 axes)
Destructive vibration resistance 10 to 55 Hz (1 cycle/min), Single amplitude: 0.375 mm 0.015 inch (1 hr. on 3 axes)
Functional shock resistance Min. 98 m/s
2
(4 times on 3 axes)
Destructive shock resistance Min. 294 m/s
2
(5 times on 3 axes)
Operating
conditions
Operation temperature 10 to 55°C +14 to +131°F (without frost or dew)
Storage temperature 25 to +65°C 13 to +149°F (without frost or dew)
Ambient humidity 35 to 85% RH (non-condensing)
Protective construction IP66 (front panel with mounting bracket and rubber gasket)
Part names
1. Front reset key
This key resets the count value. It does
not work when the lock switch is ON.
2. Mode key
Use to switch between each mode.
3. Setting key
Used to set digits of preset values or set
each mode.
4. Set key
Use to set preset values or to switch
between modes.
5. Lock switch
Disable the operation of the front panel
reset key and the mode key. With the lock
switch on, is displayed for about
two seconds when the reset key or mode
switch is operated.
6. Count speed switch
Use this switch to switch the count speed
between 30 Hz and 5 kHz.
: Default setting when shipped.
Notes: 1. Make the switch setting before installing to panel.
2. Please turn the power off if you change the setting of the count speed switch when the power is on. The
setting will become valid when the power is turned back on.
5
Lock switch
(unit display 1)
6
Count speed switch
(unit display 2)
RESET MODE SET
COUNTER LC2H
1234
6
5
(Terminal block side)
(LCD side)
OFF
ON
(Terminal block side)
(LCD side)
5kHz
30Hz
LC2H_Preset.fm Seite 80 Donnerstag, 24. Juni 2004 3:31 15
07/2004