’06–’07 Timers/Time Switches/Counters/Hour Meters Timers/Time Switches/Counters/Hour Meters ’06–’07 Please contact .......... Matsushita Electric Works, Ltd. Automation Controls Business Unit Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan Telephone: +81-6-6908-1050 Facsimile: +81-6-6908-5781 http://www.nais-e.com/ All Rights Reserved © 2006 COPYRIGHT Matsushita Electric Works, Ltd. ARCT1B274E 200610-3YT Specifications are subject to change without notice. Printed in Japan.
LC2H LC2H Counters DIN HALF SIZE LCD COUNTER Features 1. 8.7 mm .343 inch Character Height (previously 7 mm) Easy-to-read character height increased from 7 mm to 8.7 mm .276 inch to .343 inch. Panel mounting type One-touch installation type 8.7mm .343inch 2. Plenty of Digits 8 digits Panel mounting type Installation frame type 3. Counting Speed Switchable between 2 kHz and 30 Hz 4.
LC2H 2) Installation frame type 1 Standard type No. digits 8 digits Counting speed Front reset 2 kHz/30 Hz switchable Yes 30 Hz Input method Non-voltage input type Voltage input type (4.5 to 30 V DC) Free voltage input type (24 to 240 V AC/DC) Part No. LC2H-F-2KK LC2H-F-DL-2KK LC2H-F-FV-30 Input method Voltage input type (4.5 to 30 V DC) Part No. LC2H-F-DL-2KK-B Note) Please ask us about types without front resetting. 2 Backlight type No.
LC2H 2. PC board mounting type Type Item Input method No. digits Rated operation voltage Allowable operation voltage range Current consumption Max. counting speed Min. input signal width (ON: OFF = 1:1) Input method Count input Input impedance Reset input PC board mounting type Non DC voltage input 8 digits 3 V DC 2.7 to 3.3 V DC Max. 30 µA (max. 250 µA during reset input) 2 kHz 30 Hz 0.25 ms 16.7 ms Non-voltage input using contacts or open collector connection When shorted: Max. 10 kΩ When open: Max.
LC2H Part names 1. Front reset button This button resets the count value. It does not work when the lock switch is ON. Be aware that battery life will decrease if this switch is used frequently. 2. Lock switch (Refer to chart on right.) Disable the front reset button. COUNTER Count speed switch RESET LC2H Front reset button Lock switch Note) Turn ON at the LCD side (reset disabled) and OFF at the terminal block side (reset enabled). 3. Count speed switch (Refer to chart on right.
LC2H 2) Installation frame type • Panel mounting diagram 44.8 1.764 Mounting frame ATH3803 (included) Mounting screws (found on mounting frame) 54.4 2.142 37 1.457 Rubber gasket ATH3804 (included) Panel (1 to 4.5mm .039 to .177inch thickness) 10.4 .409 44 1.732 5 .197 48 1.890 COUNTER 22 .866 24 .945 RESET LC2H 7 .276 Reset button • Panel cut-out dimensions • For connected installation (sealed installation) (Only installation frame type.) The standard panel cut-out is shown below.
LC2H General tolerance: ±1.0 ±.039 mm inch 2. PC board mounting type • External dimensions PC board pattern (BOTTOM VIEW) 33.02±0.3 1.300±.012 5.08±0.3 .200±.012 0.6±0.1 .024±.004 5.08±0.3 .200±.012 Mounting area 2.54 .100 DIP switch × 8 1.9 .075 2.54 .100 3.3±0.3 .130±.012 15.24 Connection sockets .600 28 pin DIP terminal 8-0.8 dia. 8-.031 dia. 43.4 1.709 0.5±0.3 .020±.012 17.3 .681 5.19 .204 15.24±0.3 .600±.012 19 .748 1.9 5.19 .075 .204 5.08 .200 5.08 .200 33.02 1.
LC2H 2. Backlight type Voltage input type Transistor input Contact input +V Count input Backlight connection NPN transistor PNP transistor +V +V Green +V Reset input 5 1 2 3 6 4 Red 24V DC Count input 0V 5 1 2 3 6 4 Count input Reset input 5 1 2 3 6 4 Reset input 5 1 2 6 5 3 4 1 2 0V 6 3 4 24V DC Notes) 1. Do not reverse the polarities when connecting the DC voltage for the backlight. 2. 2 and 4. (The input and reset circuits are functionally insulated.) 3.
LC2H Cautions for use 1. Non-voltage input type For both panel mounting and PC board mounting types 1) Never apply voltage to the non-voltage input type. This will damage the internal elements. Also, since there is a possibility of erroneous operation, do not connect in parallel the inputs of a non-voltage input type and another counter from a single input signal.
LC2H LC2H Counter PRESET COUNTER Features 1. Preset function equipped in half size (24 × 48 mm 0.945 × 1.890 inch). 2. Display has backlight for instant recognition. Counting 3. 8.7 mm 0.343 inch Character Height (previously 7 mm 0.276 inch) Easy-to read character height increased from 7 mm to 8.7 mm 0.276 inch to 0.343 inch. Counting up Red or (Green) (backlight) Green or (Red) (backlight) Green or Red can be selected at setup. 8.7mm .343inch 4.
LC2H Specifications Item Rated operating voltage Rated power consumption Rated control capacity Input mode Max.
LC2H Part names 1. Front reset key This key resets the count value. It does not work when the lock switch is ON. 2. Mode key Use to switch between each mode. 3. Setting key Used to set digits of preset values or set each mode. 4. Set key Use to set preset values or to switch between modes. 5. Lock switch Disable the operation of the front panel reset key and the mode key. With the lock switch on, is displayed for about two seconds when the reset key or mode switch is operated. 6.
LC2H How to set 1. Preset value setting mode This is the mode for setting preset values. 2) The display reads “Un-Lock” after entering the lock mode (initial setting). Display after entering lock mode (Example showing “Un-Lock”.) Press the MODE key. Set the digit. Set the value. 1) Pressing the MODE key takes you to the preset value setting mode. 3) Pressing the setting key changes the display between “ Lock” and “Unlock”.
LC2H 5. Output setting mode This sets the operation mode. 2) Lock mode + Press the SET key while pressing the MODE key. HOLD-A SHOT-B HOLD-B SHOT-A 1) Pressing the SET key four times while holding down the MODE key takes you to the output setting mode. 2) The display reads “HoLd-A” (initial setting) after entering the output setting mode. + Press the SET key while pressing the MODE key. Un-Lock Lock When the lock is set, you cannot enter modes other than backlight setting mode.
LC2H Operation mode Output mode Output maintain/ hold count HOLD-A Operation Output control is maintained after count-up completion and until resetting. During that time, the count display does not change from that at count-up completion.
LC2H Cautions for use 1. Input and output connection 1) Input connection (1) Contact input Use highly reliable metal plated contacts. Since the contact’s bounce time leads directly to error in the count value, use contacts with as short a bounce time as possible. In general, select input to have a maximum counting speed of 30 Hz. Count input 1 2 5 6 3 4 Reset input (2) Non-contact input (Transistor input) Connect with an open collector.
LC2H PRECAUTIONS IN USING THE LC2H SERIES Cautions for use 1. Insulation sheet Before using a panel mounting type, please pull and remove the insulation sheet from the side of the product in the direction of the arrow. In consideration that the product might be stored for long periods without being used, an insulation sheet is inserted before shipping. Remove the insulation sheet and press the front reset button.
LC2H For LC2H total counter (installation frame type) (1) Remove the battery cover from the case. (2) Remove the battery from the side of the case. The battery will come loose if you put the battery side face down and lightly shake the unit. (3) Before inserting wipe clean the surface of the new battery. (4) Insert the new battery with the “+” and “–” sides in the proper position. (5) After replacing the battery, return the battery cover to the case.
COUNTERS SELECTOR CHART Classification Name of product Type LC2H Counter Total counter LC2H Counter Preset counter UP type UP, DOWN type Input mode/Input method Contact output (1 Form C) Open collector output Contact output (1 Form A) Electronic counters LC4H/-L Counter Preset counter LC4H-S Counter Preset counter UP, DOWN, and DIR (multi-mode)/DIP switch UP, DOWN, and DIR (multi-mode)/DIP switch LC4H-W Counter Preset counter UP, DOWN, and DIR (multi-mode) 2 modes selectable/DIP switch Flush m
TYPICAL COUNTER APPLICATIONS The highly accurate, reliable counters can be controlled from the front panel and are suitable for a wide range of applications. DOWN and HOLD-A modes for shipment quantity counting IND and HOLD-D modes for parking lots PHASE and HOLD-A modes for valve control Rotary encoder To valve FULL VACANT Photoelectric switch IN1 (up count) Motor IN2 (down count) (stop/start) Entrance Photoelectric switch Shipment quantities are counted to control the conveyor line flow.
COUNTER-RELATED TERMINOLOGY 1. Electro Preset Counter The counter is equipped with semiconductor counting circuitry. When the counter counts up to a preset number, its output circuit sends a signal. 2. Electro Magnetic Counter A magnet is magnetized and demagnetized to drive the dial and count up numbers. RATING 1. Rated Operating Voltage The voltage is applied to start the counter. COUNTINGS 1. Pulse This is a voltage or current signal sent at intermittent time intervals. 2.
PRECAUTIONS IN USING THE COUNTER Cautions for circuits 1. Protective circuit for counter contact In the circuit that switches an inductive load, a contact failure may occur at a contact point due to surge or inrush current resulting from that switching. Therefore, it is recommended that the following protective circuit be used to protect the contact point. Application AC DC (see note.) Available r c Diode Available Available If the load is a relay or solenoid, the release time lengthens.
PRECAUTIONS IN USING THE COUNTER Cautions for use (common for all models) 1. Terminal connections Correctly connect the pins while seeing the terminal layout/wiring diagram. In particular, the DC type, which has polarities, does not operate with the polarities connected reverse. Any incorrect connection can cause abnormal heating or ignition. 2. Connection to operating voltage 1)Apply the entire supply voltage through a switch, relay or other contact.
DIN SIZE COUNTERS COMMON OPTIONS Terminal sockets (Unit: mm inch, Tolerance: ±1 ±.039) Type Appearance Terminal wiring (Top view) Dimensions Mounting hole dimensions • DIN rail socket (8-pin) 24 .945 19 .748 50 1.969 M3.5 M.138 40 1.575 6 LC4H LC4H-L (8-pin type) 6 24 .945 4 70 2.756 35.3 1.390 7 8 1 4 50 1.969 3 2– φ 4.5 2– φ .177 3 70 2.756 70 2.756 50 1.969 5 5 70 2.756 7 8 1 40±0.2 1.575±.008 13 .512 Note: Terminal No.
DIN SIZE COUNTERS COMMON OPTIONS Mounting parts • Rubber gasket • Mounting frame Applicable for LC4H series 50.0 1.969 Applicable for LC4H series 48 1.890 1.0 .039 50.0 1.969 ATC18002 48 1.890 68 2.677 AT8-DA4 The rubber gasket is enclosed in the LC4H series. 1,000 ± 1 39.37 ± .039 • Mounting rails (Applicable for DIN and IEC standards) 5.5 .217 • Fastening plate 5 15 10 15 50 1.969 M4 M.157 12 .472 2.75R .108R 15 10 15 5 .197 .591 .394 .591 10 .394 .591 .394 .591 .197 Oval hole, 40-5.
INSTALLING DIN SIZE COUNTER Installation methods 1. Surface mount 1) For the counters of LC4H series, use the pin type counter. 2) How to mount the counter From the panel front, pass the counter through the square hole. Fit the mounting frame from the rear, and then push it in so that the clearance between the mounting frame and the panel surface is minimized. In addition, lock the mounting frame with a screw. 2) Put the terminal socket on the board directly or put it on the DIN rail (Fig. 1).
DISCONTINUED MODELS AND RECOMMENDED SUBSTITUTES Timers Discontinued models Recommended substitutes MHP-NS Exposed type Square plug-in/ horizontal type MHP-N MHP-NS- MHP-N- MHP-M Exposed type Round plug-in/ horizontal type Exposed type Round plug-in/ vertical type MHP-NM Exposed type Round plug-in/ vertical type MHP-M- MHP-NM- MHP-YC Embedded type With attachment frame MHP-N Exposed type Without attachment frame MHP-YC- MHP-N- MHP-YM Embedded type With attachment frame MHP-NM Exposed type With
Timers Discontinued models Recommended substitutes PM48W PM4H-W PM48W PM4HW- PMH-M PM4H-M/PM4S Attachment With exposed attachment, terminal base ATC180031 should be used. The external dimension and contact capacity are different.
Counters Hour meters Discontinued models Recommended substitutes MC electromagnetic counters MC6 LC48 Relay type: 8-pin Tr type: 11-pin LC4H Attachment LC4H LC4H-L LC4H Discontinued models Recommended substitutes The size and attachment method are different. The input method is different.
FOREIGN SPECIFICATIONS OVERVIEW 1. International Standards 3. Europe IEC standard EN standard International Electrotechnical Commission By promoting international cooperation toward all problems and related issues regarding standardization in the electrical and electronic technology fields, the IEC, a non-governmental organization, was started in October, 1908, for the purpose of realizing mutual understanding on an international level.
5. Pilot Duty One of the specifications in the “UL508 Industrial Control Equipment” regulations at UL (Underwriters Laboratories Inc.), has to do with the grade of contact control capacity by NEMA (National Electrical Manufacturers Association) standards. By obtaining both UL and CSA approval for this grade, the product becomes authorized publicly.
FOREIGN SPECIFICATIONS TIMER Products Name PM4S PM4H-A PM4H-S PM4H-M PM4H-SD PM4H-W PM4H-F Recognized by UL Standards File No. Certified by CSA Standards File No.
FOREIGN SPECIFICATIONS Counters Product name LC4H LC4H-L LC4H-S UL recognized File No. E122222 Approved ratings 5A250V AC PILOT DUTY C300 CSA certified File No. E122222 (C-UL) 100mA 30V DC E122222 LC4H-W 3A250V AC PILOT DUTY C300 5A250V AC PILOT DUTY C300 100mA 30V DC E122222 (C-UL) 100mA 30V DC 3A250V AC PILOT DUTY C300 100mA 30V DC E122222 24-240 V AC/DC 4.5-30 V DC 3 V DC E122222 (C-UL) 24-240 V AC/DC 4.5-30 V DC 3 V DC E122222 24-240 V AC/DC 4.
CE MARKINGS OVERVIEW Counter, Hour Meter conforming to EN/IEC standards CE markings and EC directives The Timer, Counter, Hour Meter shown below conform to both EN and IEC standards, and may display the CE markings. The world’s largest single market, the European Community (EC) was born on 1 January 1993 (changing its name to EU in November 1993. It is now always expressed as EU, apart from EC directives.