Datasheet
SPECIFICATIONS
WATT TABLE (25°C)
AMPERE TABLE (25°C)
Battery case resin: standard (UL94 HB)
Contents indicated (including the recycle marking, etc.)
are subject to change without notice.
FOR MAIN AND STANDBY POWER SUPPLIES.
EXPECTED TRICKLE DESIGN LIFE: 6 – 9 YEARS AT 20°C
ACCORDING TO EUROBAT.
DURATION OF DISCHARGE VS. DISCHARGE CURRENT
(Wattage/battery)
(Ampere/battery)
All mentioned values are average values
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
9.6V
61.1 50.1 34.3 25.9 21.3 15.6 11.7 8.90 5.95 4.60 3.20 2.41 2.01 1.81 1.11 0.602
9.9V
58.4 48.2 33.3 25.0 20.8 15.1 11.5 8.80 5.92 4.58 3.18 2.40 2.01 1.81 1.11 0.602
10.2V
54.6 45.4 32.4 24.5 20.3 14.9 11.4 8.70 5.85 4.55 3.15 2.39 2.00 1.80 1.10 0.601
10.5V
50.0 42.6 30.6 23.6 19.9 14.7 11.3 8.50 5.80 4.50 3.10 2.38 2.00 1.80 1.10 0.600
10.8V
44.5 38.9 28.7 22.7 19.4 14.2 10.5 8.30 5.60 4.40 3.05 2.37 1.99 1.79 1.09 0.598
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
9.6V
679 559 384 298 247 183 137 105 70.3 54.5 38.1 28.8 24.1 21.7 13.3 7.22
9.9V
649 537 373 288 241 177 135 104 69.9 54.2 37.8 28.7 24.0 21.7 13.3 7.22
10.2V
607 506 363 282 235 175 134 102 69.1 53.9 37.5 28.6 23.9 21.6 13.2 7.21
10.5V
556 475 343 271 231 172 133 100 68.5 53.3 36.9 28.5 23.8 21.6 13.2 7.20
10.8V
495 434 321 261 225 166 123 97.8 66.1 52.1 36.3 28.4 23.7 21.5 13.1 7.18
*
1
This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-VA1212PG/PG1.
Name
LC-RA1212PG/PG1*
1
Nominal voltage
12V
Nominal capacity (20 hour rate)
12Ah
Dimensions
Length
151mm
Width
98mm
Height
100mm
Approx. mass
3.85kg
Terminal
Faston 187/250
Capacity
(25°C)
20 hour rate
12Ah
10 hour rate
11Ah
3 hour rate
9.3Ah
1 hour rate
8.5Ah
Impedance
Fully charged battery
(25°C)
15mΩ
Temperature dependency
of capacity (20 hour rate)
40°C
102%
25°C
100%
0°C
85%
-15°C
65%
Remaining capacity
(25°C)
After 3 month
91%
After 6 month
82%
After 12 month
64%
0.1
0.3
1
31030
100
1
3
5
10
30
60
3
5
10
20
30
Dischar
g
e current (A)
Duration of discharge
0°C
40°C
25°C
-15°C
(min.)
(h)
(187)
(250)
4.75
6.35
3.2
6.35
4.5
151
+1.5
-0.5
98
+1.5
-0.5
(6)
13.5±0.75
94
+1.5
-0.5
Terminal type
(option)
LC-RA1212P*
1
G100001
INDIVIDUAL DATA SHEETS
13
DIMENSIONS (MM)
58