Datasheet

86
Valve Regulated Lead-Acid Batteries
87
Valve Regulated Lead-Acid Batteries
Individual Data Sheets
8.9
M5
16
5.61
M5
Nominal voltage
12V
Nominal capacity (20 hour rate)
28Ah
Dimensions
Length
165mm
Width
125mm
Height
175mm
Total Height
LC-X1228P: 179.5mm
LC-X1228AP: 175mm
Approx. mass
11kg
Terminal
M5 Bolt and Nut type/
M5 threaded post
Specifications
Dimensions (mm)
Duration of discharge vs Discharge current
1
3
5
10
30
60
3
5
10
20
30
)etunim(
)ruoh(
40 °C
25 °C
0 °C
-15 °C
0.3
1
3
10 30
100
Discharge current (A)
egrahcsid fo noitaruD
Capacity
(25°C)
20 hour rate
10 hour rate
5 hour rate
1 hour rate
28.0Ah
26.5Ah
25.0Ah
21.0Ah
Internal resistance
Fully charged battery
(25°C)
8mΩ
Temperature dependency
of capacity (20 hour rate)
40°C
25°C
0°C
-15°C
102%
100%
85%
65%
Self discharge
(25°C)
After 3 months
After 6 months
After 12 months
91%
82%
64%
Characteristics
For standby power supplies.
Expected trickle design life: 10 – 12 years at 20°C according to Eurobat.
LC-X1228P/AP*
1
Battery case resin:
standard (UL94HB)
Individual Data Sheets
Contents indicated (including the recycle marking, etc.)
are subject to change without notice.
(Wattage/Battery)
Cut-off V 3min 5min 10min 15min 20min 30min 45min 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 24h
9.6V 1423 1160 865 664 585 410 304 260 159 129 91.6 74.1 61.1 40.8 31.8 16.8 14.0
9.9V 1357 1093 849 654 579 404 294 254 156 128 90.4 72.9 59.9 51.6 31.8 16.8 14.0
10.2V 1301 1026 818 643 567 397 294 251 155 127 89.3 71.7 59.9 51.6 31.8 16.8 14.0
10.5V 1201 976 784 621 545 386 282 247 154 126 88.1 71.7 59.9 51.6 31.8 16.8 14.0
10.8V 1052 903 773 610 539 374 255 218 149 118 84.5 70.5 59.9 50.4 31.8 16.8 13.9
(Ampere/Battery)
Cut-off V 3min 5min 10min 15min 20min 30min 45min 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 24h
9.6V 128 104 77.2 57.7 50.4 35.0 25.9 22.1 13.5 10.9 7.7 6.2 5.1 3.4 2.65 1.40 1.17
9.9V 122 98.0 75.8 56.9 49.9 34.5 25.0 21.6 13.2 10.8 7.6 6.1 5.0 4.3 2.65 1.40 1.17
10.2V 117 92.0 73.0 55.9 48.9 33.9 25.0 21.3 13.1 10.7 7.5 6.0 5.0 4.3 2.65 1.40 1.17
10.5V 108 87.5 70.0 54.0 47.0 33.0 24.0 21.0 13.0 10.6 7.4 6.0 5.0 4.3 2.70 1.40 1.17
10.8V 94.6 81.0 69.0 53.0 46.5 32.0 21.7 18.5 12.6 10.0 7.1 5.9 5.0 4.2 2.65 1.40 1.16
Watt Table
Ampere Table
Charging Method
Trickle use
Control voltage: 13.6 - 13.8V; Initial current: 4.2A or smaller
Influence of Temperature on Trickle life
0
20
40
60
80
100
120
02468101214161820
Storage Period (Month)
)%(oitaR noitneteR yticapaC
5 °C
(41 °F)
25 °C
(77 °F)
30 °C
(86 °F)
40 °C
(104 °F)
Cut off voltage
Discharge current
1.4A -
5.6A
5.6A -
14A
14A -
28A
28A -
56A
56A -
84A
Cut off voltage (V) 10.5 10.2 9.9 9.3 8.7
Residual capacity vs storage period
0
20
40
60
80
100
120
140
160
048121620
Charge Time (h)
)%( ytitnauQ egrahC
0
2
4
6
8
10
12
14
16
)V( egatloV yrettaB
Discharge
100 % (0.05 CA*20H)
50 % (0.05 CA*10H)
Charge
Charge Voltage 13.65 V
(2.275 V / Cell)
Charge Current 0.15 CA
Temperature 25 °C (77 °F)
0.3
0.2
0.1
0
Battery Voltage
Charge Current
Charge Quantity (to-Discharge Quantity)
)AC( tnerruC egrahC
1
2
3
Constant-voltage and constant-current charge
characteristics for Trickle use
0
20
40
60
80
100
120
)%(yticapaC
Battery temperature (°C)
-20-100 1020304050
0.05 CA
0.1 CA
0.2 CA
0.5 CA
1 CA
2 CA
3 CA
Discharge capacity by temperature
and by discharge current
5
6
7
8
9
10
11
12
13
14
15
(minute) (hour)
Duration of discharge
)V(egatlov lanimreT
01 201042406024
6
8
10
20
40
68
1.4 A
2.8 A
7 A
14 A
84 A
28 A
Discharge characteristics
Terminal type
(option):
LC-X1228P
M5 bolt and nut
LC-X1228AP:
M5 threaded post
*
1
This battery is also available with a flame retardant battery case resin (UL94 V-0).
0.1
1
10
100
10 20 30 40 50060
Temperature (°C)
)sraeY( efiL ecivreS
Charging Voltage
䚭㻃
2.275 V / Cell

Summary of content (19 pages)