Operating instructions

Panasonic Digital Super Hybrid System
Product Description
36
ISSUE 1 E & O E
Class of Service
Description
Each extension is allocated a class of service. The class of service determines the following:
1. Call barring level day
2. Call barring level night
3. Exchange line call duration limit
4. Whether the extension is permitted to call forward calls to an external number
5. If the extension is allowed to override do not disturb
6. If the extension is forced to enter an account code to make external calls.
7. The level of call barring applied to system speed dial numbers used by an extension
8. If the extension may use the door opener
9. Whether the extension may set the system into or out of night service
10. If the extension is permitted to set DND for DDI calls
11. If the extension may use call forward - follow me
12. Whether the extension may use CLIR (Calling Line Identification Restriction)
13. Whether the extension may use COLR (Connected Line Identification Restriction)
14. If the extension may use the ISDN controlled call forward services
Benefits
Controls the level of facilities and features available to extensions.
Primary / Secondary Class of Service
Description
Each extension has two classes of service assigned to it. The operator can alter which class of service applies
to an extension and therefore control the facilities available.
Benefits
Useful for controlling calls made by any extension. If the user of the extension is absent calls of a certain type
can be controlled by the operator.
Connected Line Identification Restriction
Description
When an incoming call arrives at the KX-TD208E system on an ISDN line the telephone number of the line is
has arrived on is presented to the caller as confirmation of the number reached. The KX-TD208E is capable of
disabling this confirmation to the caller.
Benefits
If the call has been forwarded to the KX-TD208E system from elsewhere the caller is not to know that the call
has been re-directed.