Operation Manual

(*1) When adding “01” (hex) to default value, sending level
increases by 1.0dB.
ex.)
Item Default Data New Data
1C 1D 1B
Sending level -9.0dBm -8.0dBm -10.0dBm
(*2) When reducing “01” (hex) from default value, receiving
level increases by 1.0dB.
ex.)
Item Default Data New Data
5B 5A 5C
Receiving level -23.0dBm -24.0dBm -22.0dBm
Note:
*: When you enter the address, please refer to the table in Note: (P.51) of ENGINEERING MODE.
ex.)
Items (*4) Address Default Data New Data Possible Adjusted
Value MAX (hex)
Possible Adjusted
Value MIN (hex)
Remarks
Sending level 0F 35 Adjusted value Given value 30 00 (*1)
Receiving level 0F 37 Adjusted value Given value 70 40 (*2)
Battery Low 0F 04 9A - - -
(*3)
Frequency 00 00~00 01 00 60 - - -
ID 00 30~00 34 Given value - - -
(*3) Use these items in a READ-ONLY mode to confirm the contents. Careless rewriting may cause serious damage to the
Handset.
(*4)
Items Description
Sending level Analog Front End MIC Setting for Handset Mode
Receiving level Analog Front End LSR Setting for Handset Mode
Battery Low ADC value for battery low detection
Frequency Setting value of FREQ_TRIM_REG
ID International Portable Part Equipment Identities
53