ORDER NO. KM40507819CE Telephone Equipment KX-TCD150FXB KX-TCD150FXC KX-TCD152FXB KX-TCA115EXB KX-TCA115EXC Digital Cordless Phone Black Version Dark Blue Version (for Central Europe) © 2005 Panasonic Communications Co., Ltd. All rights reserved. Unauthorized copying and distribution is a violation of law.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC Note: Because CONTENTS 4 is the extract from the Operating Instructions of this model, it is subject to change without notice. You can download and refer to the original Operating Instructions on TSN Server for further information. CONTENTS Page 1 ABOUT LEAD FREE SOLDER (PbF: Pb free) Page 9.3. Adjustment Standard (Handset) 4 1.1. Suggested PbF Solder 4 1.2.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 30 FOR SCHEMATIC DIAGRAM 23.4. BRIDGE MODIFICATION PROCEDURE 55 67 24 CABINET AND ELECTRICAL PARTS (BASE UNIT) 56 30.1. Base Unit (SCHEMATIC DIAGRAM (BASE UNIT)) 67 25 CABINET AND ELECTRICAL PARTS (HANDSET) 57 30.2. Handset (SCHEMATIC DIAGRAM (HANDSET)) 67 26 CABINET AND ELECTRICAL PARTS (CHARGER UNIT) 58 30.3. Charger Unit (SCHEMATIC DIAGRAM (CHARGER UNIT)) 27 ACCESSORIES AND PACKING MATERIALS 59 67 27.1.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 1 ABOUT LEAD FREE SOLDER (PbF: Pb free) Note: In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that contains lead. We will use PbF solder when discussing the lead free solder used in our manufacturing process which is made from Tin (Sn), Silver (Ag), and Copper (Cu).
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 1.2. How to recognize that Pb Free solder is used (Example: Handset P.C.B.) Marked 31 30 1 100 1 10 IC1 PbF 50 51 81 80 17 8 1 IC2 4 IC3 5 (Component View) Note: The location of the “PbF” mark is subject to change without notice. 2 FOR SERVICE TECHNICIANS ICs and LSIs are vulnerable to static electricity. When repairing, the following precautions will help prevent recurring malfunctions. 1.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 4 OPERATING INSTRUCTIONS 4.1. BATTERY 4.1.1. Battery Installation Insert the batteries negative ( ) terminal first. Close the handset cover. Note: · Use only rechargeable P03P (HHR-4EPT) batteries. 4.1.2. Battery Charge Place the handset on the base unit for about 7 hours before initial use. 4.1.3.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 4.2. LOCATION OF CONTROLS 4.2.1. Base Unit 4.2.2. Handset 4.3.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 4.4. 4.4.1. Guide to Settings Base Unit Cross Reference: For Service Hint (P.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 4.4.2. Handset Cross Reference: For Service Hint (P.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 4.5.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 5 DISASSEMBLY INSTRUCTIONS 5.1. Base Unit Shown in Fig.1 2 To Remove Lower Cabinet Main P.C. Board Remove Screws (2.6 × 12)..........(A) × 2 Solders Main P.C.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 5.2. Handset Shown in Fig.3 4 5 To Remove Cabinet Cover Main P.C. Board Remove Screws (2 × 8)..........(B) × 2 Follow the procedure. Screw (2 × 8)..............(C ) × 3 Tapes and Solders Main P.C.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 5.3. Charger Unit Shown in Fig.6 7 To Remove Lower Cabinet Main P.C. Board Remove Screws (2.6 × 14)..........(D) × 2 Solders Main P.C.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 6 ASSEMBLY INSTRUCTIONS 6.1. Warning When Constructing the Base Unit CHG terminal is properly fit in the cabinet. OK NG Rib CHG terminal comes out of rib by pulling black lead wire when opening the cabinet and turning the PCB over. The terminal cannot have enough elastic force, cannot have good contact with handset, and it will result in charge problem.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 6.2.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 7 TROUBLESHOOTING GUIDE Flow Chart Cross Reference: Check Power (P.17) Bell Reception (P.22) Check Battery Charge (P.18) Check Link (P.19) Check Handset Transmission (P.21) Check Handset Reception (P.21) SIGNAL ROUTE (P.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 7.1. 7.1.1. Check Power Base Unit Is the AC Adaptor inserted into AC outlet? (Check AC Adaptor’s specification.) Cross Reference Note: Power Supply Circuit (P.41) 7.1.2. BBIC is IC2. Handset Cross Reference Note: Power Supply Circuit/Reset Circuit (P.44) BBIC is IC1.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 7.2. 7.2.1. Check Battery Charge Base Unit Cross Reference: Power Supply Circuit (P.41) 7.2.2. Handset Note: Cross Reference: BBIC is IC1. Check Power (P.17) Charge Circuit (P.44) 7.2.3. Charger Unit Cross Reference: Power Supply Circuit (P.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 7.3. 7.3.1. Check Link Base Unit Cross Reference: Power Supply Circuit (P.41) Check Point (Base Unit) (P.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 7.3.2. Handset Cross Reference Power Supply Circuit/Reset Circuit (P.44) Check Point (Handset) (P.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 7.4. Check Handset Transmission Cross Reference: SIGNAL ROUTE (P.46) 7.5. Check Handset Reception Cross Reference: HOW TO CHECK THE HANDSET SPEAKER (P.37). SIGNAL ROUTE (P.46) 7.6. Check Caller ID Cross Reference: SIGNAL ROUTE (P.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 7.7. 7.7.1. Bell Reception Base Unit Note: BBIC is IC2. 7.7.2. Handset Note: Cross Reference: BBIC is IC1. Telephone Line Interface (P.42) Check Link (P.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 8 TROUBLESHOOTING BY SYMPTOM (BASE UNIT AND CHARGER UNIT) If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester (*1) or not. Note: (*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic level in detail. (*2) Refer to Check Point (Base Unit) (P.23) 8.1.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC Items (D)* BBIC Confirmation Adjustment Point - Procedure 1. BBIC Confirmation (Execute the command “getchk”). 2. Confirm the returned checksum value. Check or Replace Parts IC2,X1,C32, C33 Connection of checksum value and program number is shown below. (E)* BBIC Clock Adjustment (Important) TP1 1. Execute the command “deactmac”. 2. Execute the command “conttx”. IC2,IC3,L1, C48,X1,C32, C33 3.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC Items (K) Sensitivity Receiver Confirmation Adjustment Procedure Point Follow steps 1 to 3 of (H) above. 4. Set DECT tester power to -88dBm. 5. Confirm that the BER is < 1000ppm. (L) Timing Confirmation - Follow steps 1 to 3 of (H) above. 4. Confirm that the Timing accuracy is < ± 2.0ppm. (M)* RSSI Level Confirmation - Follow steps 1 to 3 of (H) above. 4. Set DECT tester power to -88dBm. 5. Execute the command “readrssi”. 6.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC Items (O)* Transmit Audio Check and Adjustment Adjustment Point ANT J1 Procedure 1. Configure the DECT tester (CMD60) as follows; · Test mode: FP · Mode: Normal · PMID: 00000 2. Execute the command “testmode”. 3. Initiate connection from DECT tester. 4. Execute the command “hookoff”. 5. Execute the command “openau”. 6. Connect J1 (Telephone Socket) to Tel-simulator which is connected with 600 Ω. 7.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 8.2. 8.2.1. 8.2.1.1. The Setting Method of JIG (Base Unit) Preparation Equipment Required · DECT tester: Rohde & Schwarz, CMD 60 is recommended. · Frequency counter: it must be precise to be able to measure 1Hz (precision; ±4ppm). Hewlett Packard, 53131A is recommended. · DC power: it must be able to output at least 1A current under 9V. · Digital multi-meter (DMM): it must be able to measure voltage and current. · Oscilloscope 8.2.
Adjustment Standard (Base Unit) MIC 6.
LOOP Simulator GND TP45 OSC AF VOLT METER CHARGE TP39 TP45 (*1) Refer to Connections (P.27) (A) - (P) is referred to Check Point (Base Unit) (P.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 8.4. Check Point (Charger Unit) Items (A) Charging Check Adjustment Point - Procedure Check or Replace Parts D1,R1,R2 1. Connect Charge Contact 12Ω/2W resistor between charge+ and charge-. 2. Measure and confirm voltage across the resistor is 2.7V ± 0.2V. Note: After the measuring, sock up the solder of TP. The connection of adjustment equipment are as shown in Adjustment Standard (Charger Unit) (P.30). 8.5.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 9 TROUBLESHOOTING BY SYMPTOM (HANDSET) If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester (*1) or not. Note: (*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic level in detail. (*2) Refer to Check Point (Handset) (P.31) 9.1.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC Items (F)* Battery Monitor Confirmation & Adjustment (Important) Adjustment Point - Procedure 1. Apply 2.3V ± 0.005V between TP3(+) and TP4(-) with DC power. 2. Execute the command “deactmac” to stabilize the value. 3. Then,execute the command “readbatt”.The returned value is XX. 4. Confirm that XX is between 98 and A8.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC Items (O)* Receive Audio Check and Confirmation Adjustment Point TP15 Procedure 1. Configure the DECT tester (CMD60) as follows; · Test mode: PP · Mode: Normal · RFPI: 0102030405 2. Execute the command “testmode”. Check or Replace Parts IC1,C67,C68, R17,R20, D7,D6,IC3, C54,C66, C60,L3,C57, C55,C56, C62,R23,R24, C63,C64, C65,R18 3. Execute the command “regcmd60” 4. Initiate connection from DECT tester. 5.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 9.2. 9.2.1. 9.2.1.1. The Setting Method of JIG (Handset) Preparation Equipment Required · DECT tester: Rohde & Schwarz, CMD 60 is recommended. · Frequency counter: it must be precise to be able to measure 1Hz (precision; ± 4ppm). Hewlett Packard, 53131A is recommended. · DC power: it must be able to output at least 1A current under 2.4V for Handset, 9V for JIG.
Adjustment Standard (Handset) 35 SDL (*1) Refer to Connections (P.34) R21 5 GND 8 TP10 50 51 GND (*1) IC2 (C) (E) (F) (H) (I) (O) (P) PC I2C PCB (JIG) SDA SCL4 1 C3 R4 SDA Q2 31 30 C23 TP22 C18 R19 D5 C25 IC1 TP12 BAT C27 R18 C21 TP16 PQUP11176W TP18 TP18 81 80 1 100 C20 Digital (B) Volt Meter GND R11 R16 C22 (A) - (P) is referred to Check Point (Handset) (P.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 10 THINGS TO DO AFTER REPLACING IC Cautions: Since this page is common to each country, it may not apply to some models in your country. The contents below are the minimum adjustments required for operation. 10.1. Base Unit IC Programs for Voice processing, interface for RF and EEPROM EEPROM Adjustment parameter data (country version batch file, default batch file, etc.) Necessary Adjustment 1.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 11 RF SPECIFICATION 11.1. Base Unit Item TX Power Modulation Frequency Offset RX Sensitivity Timing Accuracy RSSI Level Value More than 20 dBm ~ 25 dBm 340 kHz/div ~ 402 kHz/div -50 kHz ~ +50 kHz < 1000 ppm < ± 2.0 ppm 0x34 hex ± F hex Refer to -.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 13 FREQUENCY TABLE (MHz) Channel No 1 2 3 4 5 6 7 8 9 10 BASE UNIT Transmit Frequency Receive Frequency 1897.344 1897.344 1895.616 1895.616 1893.888 1893.888 1892.160 1892.160 1890.432 1890.432 1888.704 1888.704 1886.976 1886.976 1885.248 1885.248 1883.520 1883.520 1881.792 1881.792 Note: Channel No. 10: In the Test Mode on Base Unit and Handset. 38 HANDSET Transmit Frequency Receive Frequency 1897.344 1897.344 1895.616 1895.
to AC Adaptor to Tel_Line A B J2 J1 39 2.65V Reg. 4.0V Reg. Limit Resistor 2.65V 4.0V VUNREG CHARGE CONTACT BBIC Interface Bridge Rect IC1 EEPROM Hook Switch 6 5 41 40 27 DTXAF SCL SDA 26 61 DTXAF HOOK TXAF 28 RXAF 24 RINGER Audio 14 BLOCK DIAGRAM (BASE UNIT) CPU Analog Front End D/A A/D DSP ADPCM Codec Filter Speech Decoding Speech Encoding BBIC IC2 BMC 16 18 30 11 63 64 6 9 5 XTAL 10 IC3 5 12 4 31 19 10.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 15 CIRCUIT OPERATION (BASE UNIT) 15.1. Outline Base Unit consists of the following ICs as shown in BLOCK DIAGRAM (BASE UNIT) (P.39).
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 15.2. Power Supply Circuit The power is supplied to the DECT BBIC, RF Module, EEPROM, Relay Coil, LED and Charge Contact from AC Adaptor (+6V) as shown in Fig.101. The power supply is as follows:
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 15.3. Telephone Line Interface · Bell signal detection · Clip signal detection · ON/OFF hook circuit · Audio circuits Bell & Clip (: Calling Line Identification Presentation: Caller ID) signal detection: In the standby mode, Q2 is open to cut the DC loop current and decrease the ring load.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 16 BLOCK DIAGRAM (HANDSET) ANT 42 EARPIECE D/A 41 46 45 MIC A/D Speech Decoding Burst Decoding Speech Encoding Burst Encoding 12 RXDA 16 TXDA 48 RSSI Analog Front End ADPCM Codec Filter RF Interface DSP BMC TP5 + CHARGE CONTACTS 13 SYEN 4 RF Module 5 IC3 12 10 33 XTAL CHARGE CIRCUIT CHARGE 38 CHARGE DETECT 27 10.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 17 CIRCUIT OPERATION (HANDSET) 17.1. Outline Handset consists of the following ICs as shown in BLOCK DIAGRAM (HANDSET) (P.43).
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 18 CIRCUIT OPERATION (CHARGER UNIT) 18.1. Power Supply Circuit The power supply is as shown.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 19 SIGNAL ROUTE 46
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 20 CPU DATA (BASE UNIT) 20.1.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC Pin 63 64 Description ANT1 ANT2 I/O D.O D.O Hi ANT1_ON ANT2_ON Hi-z - Low ANT1_OFF ANT2_OFF Remarks - Hi PA ON Transmit No Key No Key No Key No Key No Key SW OFF Charge Non Active Active Active Active Hi-z - Low PA OFF Recieve Key_In Key_In Key_In Key_In Key_In SW_ON No_charge Active Non_Active Non_Active Remarks for charge - Note: I_PU; Internal Pull-Up, I_PD; Internal Pull-Down 21 CPU DATA (HANDSET) 21.1.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC Pin 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 Description LCD_SEGMENT LCD_SEGMENT LCD_SEGMENT KEY_STRB KEY_STRB LCD_SEGMENT LCD_SEGMENT VDD VSS VDD for EEPROM I2DAT I2CLK MODE R2 (NO USE) VBACK/P0.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 22 ENGINEERING MODE 22.1.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC Note: *: When you enter the address, please refer to the table below. Desired Number (hex) 0 1 . . . 9 Input Keys 0 1 . . . 9 Desired Number (hex) A B C D E F Input Keys [R] + 0 [R] + 1 [R] + 2 [R] + 3 [R] + 4 [R] + 5 ex.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 22.2.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC Note: *: When you enter the address, please refer to the table in Note: (P.51) of ENGINEERING MODE. ex.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 23 HOW TO REPLACE THE FLAT PACKAGE IC Even if you do not have the special tools (for example, a spot heater) to remove the Flat IC, with some solder (large amount), a soldering iron and a cutter knife, you can easily remove the ICs that have more than 100 pins. 23.1. PREPARATION · PbF (: Pb free) Solder · Soldering Iron Tip Temperature of 700°F ± 20°F (370°C ± 10°C) Note: We recommend a 30 to 40 Watt soldering iron.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 23.3. FLAT PACKAGE IC INSTALLATION PROCEDURE 1. Temporarily fix the FLAT PACKAGE IC, soldering the two marked pins. *Check the accuracy of the IC setting with the corresponding soldering foil. 2. Apply flux to all pins of the FLAT PACKAGE IC. 3. Solder the pins, sliding the soldering iron in the direction of the arrow. 23.4. BRIDGE MODIFICATION PROCEDURE 1. Lightly resolder the bridged portion. 2.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 24 CABINET AND ELECTRICAL PARTS (BASE UNIT) 56
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 25 CABINET AND ELECTRICAL PARTS (HANDSET) Note: (*1) The rechargeable Ni-MH battery P03P (HHR-4EPT) is available through sales route of Panasonic. (*2) Attach the spacer (No. 117) to the exact location described above. (*3) This cable is fixed by welding. Refer to How to Replace the Handset LCD (P.15).
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 26 CABINET AND ELECTRICAL PARTS (CHARGER UNIT) 58
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 27 ACCESSORIES AND PACKING MATERIALS 27.1.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 27.2.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 28 TERMINAL GUIDE OF THE ICs, TRANSISTORS AND DIODES 28.1. Base Unit 28.2. Handset 28.3.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 29 REPLACEMENT PARTS LIST 1. RTL (Retention Time Limited) Ref. No. Note: The marking (RTL) indicates that the Retention Time is limited for this item. After the discontinuation of this assembly in production, the item will continue to be available for a specific period of time. The retention period of availability is dependant on the type of assembly, and in accordance with the laws governing part and product retention.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC Ref. No. R43 R44 R52 R53 R54 R57 R58 R59 R61 R66 R67 R68 R78 R79 R81 R82 R89 R90 C57 L59 Part No.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC Ref. No. D1 D3 D4 D6 D7 Part No.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC Ref. No. P1 Part No. PFPH1018Z P2 PQPP10084Z P3 PQPP10086Z P4 P5 PQPK14954Z PQPD10667Z Part Name & Description PROTECTION Unit) PROTECTION Handset) PROTECTION Charger) GIFT BOX CUSHION COVER (for Remarks Base COVER (for COVER (for 29.5. Fixtures and Tools Note: (*1) See The Setting Method of JIG (Base Unit) (P.27), and The Setting Method of JIG (Handset) (P.34).
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC Memo 66
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 30 FOR SCHEMATIC DIAGRAM 30.1. Base Unit (SCHEMATIC DIAGRAM (BASE UNIT)) Notes: 1. DC voltage measurements are taken with voltmeter from the negative voltage line. 2. This schematic diagram may be modified at any time with the development of new technology. 30.2. Handset (SCHEMATIC DIAGRAM (HANDSET)) Notes: 1. DC voltage measurements are taken with an oscilloscope or a tester with a ground. 2.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 31 SCHEMATIC DIAGRAM (BASE UNIT) L2 TP39 TP3 TP5 NC C63 LINE VOL TAGE 60V DC C1 NC R85 TP45 D2 Q2 NC R8 NC 100K 2.7K C6 C60 NC NC JMP2 R73 TP40 R70 C2 D8 6 (1) R7 NC D7 JMP7 5 NC 4 NC 0V ON-HOOK +0.7V DC OFF-HOOK SA1 60v DC 3 NC 2 NC JMP6 1 NC R77 NC C77 NC J1 +60V DC ON-HOOK +10V DC OFF-HOOK 680P/500V JMP1 680P/500V TP2 Q3 NC JMP3 Q11 NC OPTION4 RLY1 NC 9 C3 R1 K0.022 C4 1.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 0V ON-HOOK +3.9V DC OFF-HOOK C79 TP50 NC NC R12 Q7 NC NC C17 50V10 K0.15 R28 750 C16 C15 R24 NC D12 NC R92 10 NC D13 NC 33K R22 R21 100K R27 680 10K R26 22 R17 R18 3.9K R19 R16 13K NC D3 C10 C11 C9 NC R14 NC R11 390 2 1 NC R13 NC Q5 NC Q4 Q6 R91 R25 NC K0.022 (1) D6 0V ON-HOOK +9.8V DC OFF-HOOK R55 R15 NC NC C51 R56 56 R20 C12 C21 K1.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 32 SCHEMATIC DIAGRAM (HANDSET) Frequency 324KHz 4.1V DC 4.3V 0V TP14 CN3 D G TP4 2 S C14 K4.7 (1) C2 C33 2.4V BATTERY+ 1 BATTERY- K2.2 D1 TP3 10V220 47uH C15 L2 10V220 F1 R3 56 (2) Q1 R4 10K R21 0.1 TP5 R2 0.3 (3) R6 3.3K TP20 (4) 10uH 2 2 TP6 TP21 3 L5 (5) IC2 1 NC CHARGE- D4 1 39V(M) CN1 CHARGE+ 2.65V D2 Q2 L4 10uH 4 Q3 A0 VCC A1 WP A2 SCL GND SDA 8 7 6 5 EEPROM 0V PX.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC (1) (2) D3 (3) (4) (5) (6) (7) C7 K0.1 C8 D10P R8 330 TX-AF K0.1 TP11 C30 ~ R22 0 R27 C26 C24 K0.1 TP1 R20 0 (25) (26) 1 SP+ 2 SP- + - D7 D6 TP17 SP CN5 D10P C67 TP16 2.2K R17 0 D10P C68 C1P C17 R12 NC R1 C4 K0.1 RX-AF J18P C16 X1 (24) 330 K0.1 C28 K0.1 0 C5 6.3V4.7 R7 330 C6 MIC C29 K0.1 D10P (8) R5 TP2 S10 1.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 33 SCHEMATIC DIAGRAM (CHARGER UNIT) R1 TP3 22 TP4 D1 R2 DC_PLUG 2 pinL 27 1 TP1 Charge_plus TP2 Charge_minus J1 SCHEMATIC DIAGRAM (CHARGER UNIT) 72
C17 C16 R25 C15 R13 D12 D13 R92 R8 C6 D3 R5 C5 R3 R53 C7 Q3 R2 R74 R70 R73 R4 R1 R6 R82 C74 R81 C62 R20 C12 D10 C24 C25 C23 D4 64 64 C26 49 48 R58 C101 C70 C5 4 C81 DA1 C43 11 8 5 1 Bell Ringer (BBIC: 44) C91 Q10 C92 D9 C90 C95 C107 C106 R44 R43 C59 R68 18 C89 R88 C88 A202 C72 C67 C86 C66 R87 C76 28 C56 C71 CN4 A (4.0V) Bell Power Supply (5.
TP45 CHARGE TP39 TP3 TP50 TP40 74 TP5 6 TP97 4 TP82 1 Q9 input (5.5V) TP90 TP2 2 TP187 TP101 TP89 C99 Q9 output (4V) TP91 TP1 CHARGE TP10 KX-TCD150/152 CIRCUIT BOARD (BASE UNIT) Flow Solder Side View TP188 J101 J103 J104 J102 J105 RF clock (BBIC: 11 10.368MHz) GND VBACK SCL SDA +2.65V PbF 34.2.
D4 C5 75 Q3 Q2 1 C3 R4 R12 C24 IC2 R21 TP22 C18 IC1 TP12 BAT R11 R16 C22 VDD (2.
INT MIC R # 0 9 8 7 35.2.
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC 36 CIRCUIT BOARD (CHARGER UNIT) 36.1. Component View J1 D1 PbF PQUP11205Z B CIRCUIT BOARD (CHARGER UNIT) Component View 36.2. Flow Solder Side View R2 R1 TP3 TP4 PbF TP1 TP2 PQUP11205Z B CIRCUIT BOARD (CHARGER UNIT) Flow Solder Side View 77 I.N.