Datasheet

ETHEREA MULTI SPLIT 2X1 // INVERTER+
ETHEREA, A NEW CONCEPT IN AIR CONDITIONERS: AIR PURIFYING SYSTEM, STYLISH DESIGN AND HIGH EFFICIENCY. With the multi
system, save more than with the 1x1!
ECONAVI ’s sensor technology uses factors such as speed, frequency and temperature to determine the human activity level in the
room for maximum comfort and maximum savings. With ECONAVI , you can save up to 30%. Cool and stylish, the distinctive,
beautiful rounded form is designed to complement today’s modern interiors. Etherea has an advanced air purifying system with the
new Patrol Sensor to detect and eliminate contaminants.
Using a Multi Split 2x1 Inverter+ system with the outdoor unit CU-2E18LBE instead of 2 individual mono split Inverter+ systems,
you reduce consumption and thus save more! Up to 16%! Furthermore, using a Multi Split system, you save space on the outdoor
unit, making it easier to install in small spaces.
The multi system also has a greater difference in elevation and longer tubing, leading to greater flexibility on roof installations.
A
class
energy
saving
quality
air control
24 h
PATROL SENSOR
30%
savings
down to
-15ºC
in
heating mode
OUTDOOR
TEMPERATURE
pure
air system
-ION PLUS
SILVER KIT KIT-2XE99-MKE KIT-2XE912-MKE KIT-2XE1212-MKE
Indoor CS-XE9MKEW CS-XE9MKEW CS-XE12MKEW
CS-XE9MKEW CS-XE12MKEW CS-XE12MKEW
WHITE KIT KIT-2E99-MKE KIT-2E912-MKE KIT-2E1212-MKE
Indoor CS-E9MKEW CS-E9MKEW CS-E12MKEW
CS-E9MKEW CS-E12MKEW CS-E12MKEW
Outdoor CU-2E18LBE CU-2E18LBE CU-2E18LBE
Cooling capacity Nominal (Min - Max) kW 4,80 (1,50 - 5,20) 5,00 (1,50 - 5,30) 5,20 (1,50 - 5,40)
kCal/h 4.130 (1.290 - 4.470) 4.300 (1.290 - 4.560) 4.470 (1.290 - 4.640)
EER
1)
Nominal (Min - Max) Energy Saving 3,66 (6,00 - 3,42)
A
3,36 (6,00 - 3,44)
A
3,42 (6,00 - 3,42)
A
Power input Cooling Nominal (Min - Max) kW 1,31 (0,25 - 1,52) 1,49 (0,25 - 1,54) 1,52 (0,25 - 1,58)
Heating capacity Nominal (Min - Max) kW 5,60 (1,10 - 7,20) 5,60 (1,10 - 7,20) 5,60 (1,10 - 7,20)
kCal/h 4.820 (950 - 6.190) 4.820 (950 - 6.190) 4.820 (950 - 6.190)
COP
1)
Nominal (Min - Max) Energy Saving 4,48 (5,24 - 4,14)
A
4,55 (5,24 - 4,19)
A
4,63 (5,24 - 4,24)
A
Power input Heating Nominal (Min - Max) kW 1,25 (0,21 - 1,74) 1,23 (0,21 - 1,72) 1,21 (0,21 - 1,70)
Annual Energy Consumption
2)
kWh 655 745 760
INDOOR UNIT
Air Volume Cooling m³/h 606 606 (E9) / 654 (E12) 654
Moisture removal volume l/h 1,5 / 1,5 1,4 (E9) / 1,6 (E12) 1,6 / 1,6
Sound pressure level
3)
Cooling and Heating (S-Lo) dB(A) 26 26 (E9) / 29 (E12) 29
Sound power level Cooling and Heating (Hi) dB 56 56 (E9) / 60 (E12) 60
Dimensions H x W x D mm 290 x 870 x 204 290 x 870 x 204 290 x 870 x 204
Net weight kg 9 9 9
Air purifier filter Patrol + E-ion Patrol + E-ion Patrol + E-ion
OUTDOOR UNIT
Power source V 230 230 230
Connection mm² 4 x 1,5 4 x 1,5 4 x 1,5
Current
Cooling / Heating (Nominal)
A 6,10 / 5,55 6,95 / 5,45 7,10 / 5,35
Air Volume Cooling / Heating m³/h 2.070 / 1.860 2.070 / 1.860 2.070 / 1.860
Sound pressure level
3)
Cooling / Heating (Hi) dB(A) 49 / 51 49 / 51 49 / 51
Sound power level Cooling / Heating (Hi) dB 64 / 66 64 / 66 64 / 66
Dimensions
4)
H x W x D mm 540 x 780 (+70) x 289 540 x 780 (+70) x 289 540 x 780 (+70) x 289
Net weight kg 38 38 38
Piping connections Liquid pipe inch (mm) 1/4” (6,35) 1/4” (6,35) 1/4” (6,35)
Gas pipe inch (mm) 3/8” (9,52) 3/8” (9,52) 3/8” (9,52)
Refrigerant Loading R410A kg 1,45 1,45 1,45
Elevation difference (in/out)
5)
Max m 10 10 10
Piping length Total m 30 30 30
Piping length (one unit) Min / Max m 3 / 20 3 / 20 3 / 20
Piping length without
refrigerant increase
Max m 20 20 20
Additional gas g/m 20 20 20
Operating range
3)
Cooling Min / Max ºC 16 / 43 16 / 43 16 / 43
Heating Min / Max ºC -10 / 24 -10 / 24 -10 / 24
c
l
ass
ene
r
g
y
sav
i
n
g
TECHNICAL FOCUS
· NEW! MAXIMUM EFFICIENCY AND COMFORT WITH
ECONAVI
· VERY EXCLUSIVE SILVER DESIGN
· NEW GENERATION OF E-ION AIR PURIFYING SYSTEM
WITH 24-HR PATROL SENSOR
· MORE POWERFUL AIRFLOW TO QUICKLY REACH THE
DESIRED TEMPERATURE
KIT-2XE99-MKE // KIT-2XE912-MKE // KIT-2XE1212-MKE
KIT-2E99-MKE // KIT-2E912-MKE // KIT-2E1212-MKE
HEALTHY AIR
· E-ion plus air purifying system
· Patrol sensor to detect and eliminate contaminants
· Air conditioner and purifier with simultaneous or independent operation
ENERGY EFFICIENCY AND ECOLOGY
· Maximum efficiency Inverter system, for bigger savings
·
NEW!-30% consumption with ECONAVI on heat pump (-20% on cooling mode)
· R410A refrigerant gas
COMFORT
· Powerful mode
· Uniform dispersion of airflow
· Automatic vertical airflow control
· Hot start mode, increased comfort on heat pump mode, no cool airflow when process starts
· Automatic restart after power cut
EASE OF USE
· Real time clock with dual ON&OFF timer
· User friendly infrared remote control
·
NEW! Optional wired weekly timer with 6 settings per day and 42 settings per week
· NEW! Connectivity function (indoor unit equipped with PCB port which can be connected to
outside network)
EASY INSTALLATION AND MAINTENANCE
· Removable, washable panel
· 30 m maximum connection distance
· 10 m maximum elevation difference
· Maintenance access through the top panel of the outdoor unit
· Self-diagnosis function
CS-XE7MKEW // CS-XE9MKEW // CS-XE12MKEW
CU-2E18LBE
INCLUDED WITH
THE INDOOR UNIT
GLOBAL REMARKS Rating conditions Cooling Heating
Inside air temperature 27ºC DB / 19ºC WB 20ºC DB
Outside air temperature 35ºC DB / 24ºC WB 7ºC DB / 6ºC WB
DB: Dry Bulb; WB: Wet Bulb
This model is not suitable to use in heating mode below -5ºC with continuous operation (24h operation).
Connectivity restriction : CS-E/XE_MKE units are only compatible with CU-2E15LBE, CU-2E18LBE, CU-3E18LBE,
CU-4E23LBE and CU-4E27CBPG outdoor units. No other outdoor unit can be connected.
1) EER and COP classification is at 230 V in accordance with EU directive 2002/31/EC.
2) The annual consumption is calculated by multiplying the input power at 230 V by an avarage of 500 hours per
year in cooling mode.
3) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body
and 0,8 meters below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97
specification.
4) Add 70 mm for piping port.
5) When installing the outdoor unit at a higher position than the indoor unit.
NEW
2011
Specifications subject to change without notice
improved
comfort
AUTOCOMFORT
46 47
DOMESTIC