Datasheet
WALL MOUNTED ETHEREA // INVERTER+ // SILVER
NEW ETHEREA WITH ECONAVI SENSOR, MORE EFFICIENT, MORE COMFORT, MORE DESIGN, MORE HEALTHY AIR
ECONAVI sensor determine the human activity level and the position in the room and adjust the air flow orientation
for maximum comfort and maximum savings. With ECONAVI, you can save up to 30%.
Furthermore, Etherea is more efficient than ever with 64% less consumption for the non Inverter model on heat
pump mode, and can reach 71% total savings when used with ECONAVI. More efficiency for bigger savings!
Etherea has an advanced air purifying system with the new Patrol Sensor to detect and eliminate contaminants.
Etherea is also able to prevent rapid decreases in room humidity with the new mild dry cooling system which
increases comfort, especially when sleeping with the air conditioning running.
A
c
l
ass
ene
r
g
y
sav
i
n
g
30%
savings
quality
air control
24 h
PATROL SENSOR
perfect
humidity
control
MILD DRY
pure
air system
-ION PLUS
Maintains a Relative Humidity up to 10%
higher than cooling operation. Ideal when
sleeping with the air conditioner on.
A
class
energy
saving
TECHNICAL FOCUS
· NEW! MAXIMUM EFFICIENCY AND COMFORT WITH
ECONAVI
· EXCLUSIVE SILVER DESIGN
· NEW GENERATION OF E-ION AIR PURIFYING SYSTEM
WITH 24-HR PATROL SENSOR
· MILD DRY COOLING: PREVENT A RAPID DECREASE IN
ROOM HUMIDITY
· MORE POWERFUL AIRFLOW TO QUICKLY REACH THE
DESIRED TEMPERATURE
KIT-XE18-MKE // KIT-XE21-MKE
HEALTHY AIR
· E-ion plus air purifying system
· Patrol sensor to detect and eliminate contaminants
· Air conditioner and purifier with simultaneous or independent operation
· Mild Dry Cooling operation mode for increased comfort and prevention of skin moisture loss
ENERGY EFFICIENCY AND ECOLOGY
· Maximum efficiency Inverter system, for bigger savings
·
NEW! -30% consumption with ECONAVI on heat pump (-20% on cooling mode)
· R410A refrigerant gas
COMFORT
· Super Quiet mode
· Powerful mode
· Uniform dispersion of airflow
· Automatic vertical airflow control
· Hot start mode, increased comfort on heat pump mode, no cool airflow when process starts
· Automatic restart after power cut
EASE OF USE
· Real time clock with dual ON&OFF timer
· User friendly infrared remote control
·
NEW! Optional wired weekly timer with 6 settings per day and 42 settings per week
· NEW! Connectivity function (indoor unit equipped with PCB port which can be connected to
outside network)
EASY INSTALLATION AND MAINTENANCE
· Removable, washable panel
· 15 m maximum connection distance (20 m for XE18 and XE21)
· 15 m maximum elevation difference
· Maintenance access through the top panel of the outdoor unit
· Self-diagnosis function
NEW
2011
CU-E18MKE
CU-E21MKE
GLOBAL REMARKS Rating conditions Cooling Heating
Inside air temperature 27ºC DB / 19ºC WB 20ºC DB
Outside air temperature 35ºC DB / 24ºC WB 7ºC DB / 6ºC WB
DB: Dry Bulb; WB: Wet Bulb
This model is not suitable to use in heating mode below -5ºC with continuous operation (24h operation).
Connectivity restriction: JKE units are not compatible with MKE units.
1) EER and COP classification is at 230 V in accordance with EU directive 2002/31/EC.
2) The annual consumption is calculated by multiplying the input power at 230 V by an avarage of 500 hours per
year in cooling mode.
3) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body
and 0,8 meters below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97
specification.
4) Add 70 mm for piping port.
5) When installing the outdoor unit at a higher position than the indoor unit.
INCLUDED WITH
THE INDOOR UNIT
KIT KIT-XE18-MKE KIT-XE21-MKE
Indoor CS-XE18MKEW CS-XE21MKEW
Outdoor CU-E18MKE CU-E21MKE
Cooling capacity Nominal (Min - Max) kW 5,00 (0,98-6,00) 6,30 (0,98-7,10)
Nominal (Min - Max) kCal/h 4.300 (840-5.160) 5.420 (840-6.110)
EER
1)
Nominal (Min - Max) Energy Saving 3,40 (3,50-2,96)
A
2,85 (3,50-2,80)
C
Power input Cooling Nominal (Min - Max) kW 1,47 (0,28-2,03) 2,21 (0,28-2,54)
Heating capacity Nominal (Min - Max) kW 5,80 (0,98-8,00) 7,20 (0,98-8,50)
Nominal (Min - Max) kCal/h 4.990 (840-6.880) 6.190 (840-7.310)
Heating capacity at -7°C Nominal kW 4,98 5,24
COP
1)
Nominal (Min - Max) Energy Saving 3,77 (2,88-3,08)
A
3,43 (2,88-3,09)
B
Power input Heating Nominal (Min - Max) kW 1,54 (0,34-2,60) 2,10 (0,34-2,75)
Annual Energy Consumption
2)
kWh 735 1.105
INDOOR UNIT
Air Volume Cooling / Heating m³/h 978 / 1.074 1.038 / 1.110
Moisture removal volume l/h 2,8 3,5
Sound pressure Level
3)
Cooling (Hi / Lo / S-Lo) dB(A) 44 / 37 / 34 45 / 37 / 34
Heating (Hi / Lo / S-Lo) dB(A) 44 / 37 / 34 45 / 37 / 34
Sound power Level Cooling (Hi) dB 60 61
Heating (Hi) dB 60 61
Dimensions H x W x D mm 290 x 1.070 x 235 290 x 1.070 x 235
Net weight kg 12 12
Air purifier filter Patrol + E-ion Patrol + E-ion
OUTDOOR UNIT
Power source V 230 230
Connection mm² 4 x 2,5 4 x 2,5
Current Cooling Nominal A 6,6 9,9
Current Heating Nominal A 6,9 9,4
Max, current A 11,4 12,1
Air Volume Cooling / Heating m³/h 2.352 / 2.274 2.502 / 2.424
Sound pressure Level
3)
Cooling (Hi) dB(A) 47 48
Heating (Hi) dB(A) 47 49
Sound power Level Cooling (Hi) dB 61 62
Heating (Hi) dB 61 63
Dimensions
4)
H x W x D mm 695 x 875 x 320 695 x 875 x 320
Net weight kg 45 46
Piping connections Liquid pipe inch (mm) 1/4" (6,35) 1/4" (6,35)
Gas pipe inch (mm) 1/2" (12,70) 1/2" (12,70)
Refrigerant Loading R410A kg 1,22 1,28
Elevation difference (in/out)
5)
Max m 15 15
Piping length Min / Max m 3-20 3-20
Piping length without refrigerant
increase
Max m 7,5 7,5
Additional gas g/m 20 20
Operating range
3)
Cooling Min / Max °C +5 / +43 +5 / +43
Heating Min / Max °C -5 / +24 -5 / +24
Specifications subject to change without notice
improved
comfort
AUTOCOMFORT
OPTIONAL
WIRED REMOTE CONTROL
CZ-RD514C
24 25
DOMESTIC