Data Sheet

Features
Controls Microprocessor
Remote Controller LCD Wireless Type, Temp. Sensor
Built In
Temperature Control IC Thermistor
Timer 24 Hour, Single Event, ON/OFF
Timer
Options
Refrigerant Line Set Available
Fresh Air Intake Knock-Out (Dia. 3-7/8”)
Air Duct Extension N/A
Hard Wired Remote Control Available / Model Number-CZ-
RD515U
Non-Removable, Locking
Remote-Control Bracket
Available
Operating Range
Indoor Air Intake Temp
Outdoor Air Intake Temp
Cooling (Max) 95F DB/71F WB 115F DB
Cooling (Min) 67F DB/57F WB 0F DB
Heating (Max) 80F DB/67F WB 75F DB/65F WB
Heating (Min) -DB/-WB 0F DB
Performance Data @ ARI Standard Conditions (115V)
Cooling
Total Capacity (BTU/H) 11,900 (3,000-11,900)
Sensible Capacity (BTU/H) 7,200
Latent Capacity (BTU/H) 4,700
SEER 16
Dehumidification (Pints/H) 4.26
Amps (A) 12.6 (2.5-12.6)
Power Inputs (W) 1260 (250-1260)
Outdoor Sound Rating (dB-A) 51
Heating
Total Capacity (BTU/H) 13,600 (3,000-13,600)
HSPF 8.5
Amps (A) 14.6 (2.5-14.6)
Max Amps
Power Inputs (W) 1,460 (250-1,460)
Back-up Strip Heater 0.00/0.00
Outdoor Sounds Rating (dB-A) 51
Panasonic North America
Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110
Kennesaw, GA 30144
us.panasonic.com/aircon
Night Setback Included
One Hour OFF Timer Included
Air Louver, 4 Way Panel, Control (CZ-18BT1U)-4-Automatic/
Sweep/Step
Power Failure Automatic Restart Included
Condensate Drain Pump Included
Self-Diagnosis Included
High Power Included
Quiet Operation Included
Air Filter Washable, Anti-Mold